This Acti9 C120N is a low voltage multistandard miniature circuit breaker (MCB).

It is a 3P circuit breaker with 3 protected poles, 125A rated current and C tripping curve.

The rated short circuit breaking capacity goes up to 10000A at 230VAC to 400VAC conforming to EN/IEC 60898-1 standard and 10000A at 230VAC to 400VAC conforming to EN/IEC 60898-1 standard.

It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2.

This miniature circuit breaker combines functions of circuit protection against short circuit and overload current, control and isolation.

The presence of green strip guarantees contact open physically and allows work to be carried out safely on the downstream circuit.

It has good overvoltage withstand capacity.

The product is designed to offer a high industrial performance level It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles.

The Ue operational voltage is equal or below 375VDC, 220VAC to 240VAC, 230VAC to 400VAC, 380VAC to 415VAC or 440VAC.

The Ui rated insulation voltage is 500VAC The frequency is 50Hz or 60Hz.

The product can be clipped on a DIN rail.

Its width is 9 pitches of 9mm.

Pollution degree is 3.

Overvoltage category is IV.

The product colour is white (RAL9003).

The dimensions are (W) 81mm x (H) 81mm x (D) 73mm.

The weight is 0.615kg.

It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals.

The operating temperature is -25°C to 70°C.

The storage temperature is -40°C to 85°C.

More Information
More Information
Attribute Value
SKU A9N18369
product certifications EAC
relative humidity 95-95 % at 55-55 °C
ambient air temperature for storage -40-85 °C
overvoltage category IV
pollution degree 3 conforming to IEC 60947-2
ambient air temperature for operation -25-70 °C
number of protected poles 3
range of product C120
product or component type Miniature Circuit Breaker
net weight 0.615 kg
mounting mode clip-on
standards EN/IEC 60947-2, EN/IEC 60898-1
tropicalisation 2 conforming to IEC 60068-1
earth-leakage protection separate block
mechanical durability 20000 cycles
comb busbar and distribution block compatibility NO
device short name C120N
breaking capacity 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2, 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2, 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2, 10000 A Icn at 230...400 V AC 50/60 Hz conforming to EN/IEC 60898-1, 10 kA Icu at <= 375 V DC conforming to EN/IEC 60947-2
trip unit technology thermal-magnetic
range Acti 9
wire stripping length 15 mm
[Ics] rated service breaking capacity 7500 A 75 % conforming to EN/IEC 60898-1 - 230...400 V AC 50/60 Hz, 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz, 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz, 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz, 10 kA 100 % conforming to EN/IEC 60947-2 - <= 375 V DC
breaking capacity code N
[Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-2
product name C120
network frequency 50/60 Hz
connections - terminals tunnel type terminals1-50 mm² rigid, tunnel type terminals1.5-35 mm² flexible
height 81 mm
mounting support 35 mm symmetrical DIN rail
compatibility code C120
width 81 mm
depth 73 mm
operating altitude 2000 m
IP degree of protection IP20 conforming to IEC 60529
[In] rated current 125 A at 30 °C
curve code C
network type AC
9 mm pitches 9
poles description 3P
colour white
tightening torque 3.5-3.5 N.m
electrical durability 5000 cycles conforming to IEC 60947-2
device application distribution
control type toggle
[Ue] rated operational voltage 220...240 V AC 50/60 Hz, 380...415 V AC 50/60 Hz, 440 V AC 50/60 Hz, <= 375 V DC, 230...400 V AC 50/60 Hz
magnetic tripping limit 5...10 x In
local signalling ON/OFF indication
market segment small commercial, residential
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN/IEC 60947-2
suitability for isolation yes conforming to IEC 60947-2
contact position indicator yes
limitation class 3 conforming to EN/IEC 60947-2