Acti 9 iCT 25A 2NC 230...240V 50Hz contactor - A9C20736
This Acti9 iCT is a modular contactor.
It is a 2P remote control device with 2 normally close contacts.
The In rated current is 25A for AC-7a and 8.5A for AC-7b.
The Ue rated operational voltage is 250VAC.
The Uc control voltage is 230VAC to 240VAC.
This device could be used for control circuits.
This device could be used for remote switching lighting loads, small motors (fans, mixers) or HVAC system applications.
It is compatible with all the Acti9 control auxiliaries, for lighting, heating & ventilation control applications.
This product is compliant with IEC/EN 61095 standard.
Electrical endurance goes up to 100000 cycles for AC-7A or AC-1, 30000 cycles for AC-7C, AC-7B, AC-3, AC-5A or AC-5B.
The maximum switching operations is 100 per day.
The Ui rated insulation voltage is 500VAC.
The Uimp rated impulse withstand voltage is 4kV.
Pollution degree is 2.
It is DIN rail mountable.
Its width is 2 pitches of 9mm.
The product color is white (RAL9003).
The dimensions are (W) 81mm x (H) 18mm x (D) 68.5mm.
According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure.
The operating temperature is from -5°C to 60 °C.
The storage temperature is from -40°C to 70°C.
Attribute | Value |
---|---|
SKU | A9C20736 |
relative humidity | 95-95 % at 55-55 °C |
ambient air temperature for storage | -40-70 °C |
pollution degree | 2 |
ambient air temperature for operation | -5-60 °C |
range of product | iCT |
product or component type | Kontaktor |
mounting mode | clip-on |
standards | IEC/EN 61095 |
tropicalisation | 2 conforming to EN 60947-4-1, 2 conforming to EN 61095, 2 conforming to IEC 1095 |
mechanical durability | 1000000 cycles |
device short name | iCT |
range | Acti 9 |
product compatibility | iACTs, iACTp, iATEt, iACTc |
[Ie] rated operational current | 25 A AC-7A, 8.5 A AC-7B |
[Uc] control circuit voltage | 230...240 V AC 50 Hz |
[Uimp] rated impulse withstand voltage | 4 kV |
product name | Acti 9 iCT |
pole contact composition | 2 NC |
hold-in power consumption in VA | 2.7-2.7 VA |
inrush power in VA | 9.2 VA |
maximum power | 1.2 W at 250 V AC |
network frequency | 50 Hz |
connections - terminals | control circuit: tunnel type terminals2 cable(s) 1.5-1.5 mm² rigid, power circuit: tunnel type terminals1 cable(s) 1-4 mm² flexible, power circuit: tunnel type terminals1 cable(s) 1.5-6 mm² rigid, control circuit: tunnel type terminals1 cable(s) 1.5-2.5 mm² rigid, control circuit: tunnel type terminals2 cable(s) 1.5-2.5 mm² flexible |
height | 81 mm |
mounting support | 35 mm symmetrical DIN rail |
compatibility code | iCT |
width | 18 mm |
depth | 68.5 mm |
operating altitude | 2000 m |
IP degree of protection | IP20 conforming to IEC 60529, IP40 (modular enclosure) conforming to IEC 60529 |
network type | AC |
9 mm pitches | 2 |
poles description | 2P |
colour | white |
tightening torque | control circuit: 0.8-0.8 N.m, power circuit: 0.8-0.8 N.m |
electrical durability | 30000 cycles IEC/EN 61095 50 Hz AC-7C, 100000 cycles EN/IEC 60947-4-1 50 Hz AC-1, 30000 cycles EN/IEC 60947-4-1 50 Hz AC-3, 30000 cycles EN/IEC 60947-4-1 50 Hz AC-5a, 30000 cycles EN/IEC 60947-4-1 50 Hz AC-5b, 100000 cycles IEC/EN 61095 25 A 50 Hz AC-7A, 30000 cycles IEC/EN 61095 8.5 A 50 Hz AC-7B |
device application | motor-heating-lighting |
control type | remote control |
[Ue] rated operational voltage | 250 V AC 50 Hz |
local signalling | action indicator |
market segment | small commercial, residential |
[Ui] rated insulation voltage | 500 V AC 50/60 Hz |
heat dissipation | 0.9-0.9 W at 50/60 Hz |
control signal type | maintained |
noise level | 30 dB |
switching frequency | 100 switching operations/day |