Acti 9 PRD1 Master modular surge arrester - 3 poles + N - 350V - with remote transfer - 16363
This Acti9 PRD1 Master is a surge arrester with pluggable cartridge.
It has 3P+N pole.
The maximum continuous operating voltage is 350V (L-N or N-PE).
It is available for TT or TN-S earthing system.
It is a type 1 surge arrester.
It protects electrical installations against direct lightning strikes.
It is fitted with easy-to-replace withdrawable cartridges.
The device has an end-of-life indication (white for correct operation, red at end of life) with remote signalling.
The nominal discharge current (impulse 8-20 µs) is 25kA with a maximum of 50kA.
The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 350VAC.
The Uc maximum continuous operating voltage in common mode (between neutral and earth) is 350VAC.
The maximum lightning current Iimp (impulse current 10-350 µs) is 25kA between L-N and 100kA between N-PE.
The rated voltage network is 230VAC or 400VAC.
The voltage protection level goes up to 1.5kV.
The dimensions are (W) 18mm x (H) 90mm x (D) 66mm.
The width in 9mm pitches is 8.
The degree of protection is IK05 and IP20 on its terminals becoming IP40 once in modular enclosure.
It can be mounted on DIN rail for modular installation.
Its width is 16 modules of 9mm.
This product is compliant with EN 61643-11 standard.
Attribute | Value |
---|---|
SKU | 16363 |
product certifications | CE |
relative humidity | 5-90 % |
ambient air temperature for storage | -40-80 °C |
ambient air temperature for operation | -25-60 °C |
quality labels | KEMA-KEUR |
range of product | PRD1 Master |
product or component type | Surge Arrester |
net weight | 1.31 kg |
mounting mode | clip-on |
standards | IEC 61643-11:2011, EN 61643-11:2012 |
device short name | PRD1 Master |
range | Acti 9 |
surge arrester class type | type 1 |
IK degree of protection | IK05 conforming to IEC 62262 |
product name | Acti 9 PRD1 Master |
surge arrester type | electrical distribution network |
signalling circuit voltage | 1 A/250 V AC 50/60 Hz |
connections - terminals | tunnel type terminal (downside) 2.5-35 mm², tunnel type terminal (upside) 2.5-35 mm² |
height | 90 mm |
mounting support | DIN rail |
compatibility code | PRD1_Master |
width | 142.8 mm |
depth | 70 mm |
operating altitude | 2000 m |
IP degree of protection | IP40 on front face: conforming to IEC 60529, IP20 built-in: conforming to IEC 60529 |
9 mm pitches | 16 |
poles description | 3P + N |
colour | anthracite grey (RAL 7016) |
tightening torque | 4.5-4.5 N.m |
device application | distribution |
[Ue] rated operational voltage | 230/400 V AC (+/- 10 %) at 50/60 Hz |
disconnector device type | associated fuse gG 315 A standard, associated circuit breaker Compact NSX100F 100 A curve C - Icu 36 kA, associated circuit breaker Compact NSX100N 100 A curve C - Icu 50 kA |
surge arrester technology | spark gap |
response time | < 100 ns |
maximum [Up] voltage protection level | common mode <1.5 kV type 2 N/PE, differential mode <1.5 kV type 2 L/N |
nominal discharge current | common mode: 100 kA (N/PE), differential mode: 25 kA (L/N) |
earthing system | TT, TN-S |
[Uc] maximum continuous operating voltage | differential mode: 350 V L/N, common mode: 350 V N/PE |
material | PBT (polybutylene terephthalate) |
market segment | small commercial |
signal contacts composition | 1 SD (1 C/O) |
remote signalling | with |
[If] follow current | 0.1 kA common mode N/PE, 50 kA differential mode L/N |
[Iimp] impulse current | common mode: 100 kA N/PE 50 A.s, differential mode: 25 kA L/N 12.5 A.s |
impulse current | 25 kA |