Altivar 212 variable speed drive ATV212 - 22kW - 30hp - 480V - 3ph - EMC - IP21 - ATV212HD22N4
This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262.
The analogue output module provides 2 outputs with 11bit + sign and 12bit resolution.
It is an output module with a rated supply voltage of 24V DC and a current consumption of 70mA at 24V DC via external supply full load.
This product is capable of controlling variable speed drives or any device equipped with a current or voltage input.
There is an insulation between output and supply at 1500V AC, output and internal logic at 500V AC.
It is furnished with removable screw terminal for electrical connection with 5.08mm pitch adjustment for outputs.
It is an IP20 rated product.
Its dimensions are 23.6mm (Width) x 70mm (Depth) x 90mm (Height).
It weighs 0.115kg.
This product is certified by CE.
It meets EN/IEC 61131-2 and EN/IEC 61010-2-201 standards.
This module is compatible with Modicon M262, Modicon M241, Modicon M251 and Modicon M221 logic controller.
It supports top hat type TH35-15, top hat type TH35-7.5 rail conforming to IEC 60715 and plate or panel with fixing kit mount.
Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism.
A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers.
Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.
Attribute | Value |
---|---|
SKU | ATV212HD22N4 |
product certifications | CSA, UL, C-Tick, NOM 117 |
relative humidity | 5-95 % without condensation conforming to IEC 60068-2-3, 5-95 % without dripping water conforming to IEC 60068-2-3 |
ambient air temperature for storage | -25-70 °C |
pollution degree | 3 conforming to IEC 61800-5-1 |
ambient air temperature for operation | -10-40 °C (without derating), 40-50 °C (with derating factor) |
environmental characteristic | classes 3C1 conforming to IEC 60721-3-3, classes 3S2 conforming to IEC 60721-3-3 |
motor power hp | 30 hp |
continuous output current | 43.5 A at 380 V, 43.5 A at 460 V |
isolation | electrical between power and control |
output voltage | <= power supply voltage |
range of product | Altivar 212 |
operating position | vertical +/- 10 degree |
product or component type | Soft Starter & Variable Speed Drive |
net weight | 26.4 kg |
standards | IEC 61800-5-1, IEC 61800-3, EN 61800-3 environments 1 category C2, EN 61800-3 category C2, IEC 61800-3 environments 1 category C1, IEC 61800-3 environments 2 category C1, IEC 61800-3 environments 2 category C2, IEC 61800-3 environments 1 category C2, EN 55011 class A group 1, EN 61800-3 environments 1 category C3, IEC 61800-3 environments 1 category C3, EN 61800-3, IEC 61800-3 category C3, EN 61800-3 category C3, IEC 61800-3 category C2, EN 61800-5-1, UL Type 1, IEC 61800-3 environments 2 category C3, EN 61800-3 environments 1 category C1, EN 61800-3 environments 2 category C2, EN 61800-3 environments 2 category C3, EN 61800-3 environments 2 category C1 |
device short name | ATV212 |
range | Altivar Building ATV212 |
minimum switching current | 3 mA at 24 V DC for configurable relay logic |
insulation resistance | >= 1 mOhm 500 V DC for 1 minute |
power range | 15-25 kW at 380-440 V 3 phases, 15-25 kW at 480-500 V 3 phases |
motor starter type | variable speed drive |
[Us] rated supply voltage | 380...480 V - 15...10 % |
electromagnetic compatibility | voltage dips and interruptions immunity test conforming to IEC 61000-4-11, electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
analogue input type | VIA switch-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits, VIB configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits, VIB configurable PTC probe: 0...6 probes, impedance: 1500 Ohm, VIA switch-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 10 bits |
electrical connection | VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5-2.5 mm² / AWG 14, L1/R, L2/S, L3/T: terminal 50-50 mm² / AWG 1/0 |
discrete output type | configurable relay logic: (FLA, FLC) NO - 100000 cycles, configurable relay logic: (FLB, FLC) NC - 100000 cycles, configurable relay logic: (RY, RC) NO - 100000 cycles |
line current | 33.1 A at 480 V, 41.6 A at 380 V |
speed drive output frequency | 0.5-200 Hz |
asynchronous motor control profile | voltage/frequency ratio, 5 points, flux vector control without sensor, standard, voltage/frequency ratio - Energy Saving, quadratic U/f, voltage/frequency ratio, 2 points, voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) |
maximum transient current | 47.9 A for 60 s |
analogue output number | 1 |
nominal switching frequency | 8 kHz |
braking to standstill | by DC injection |
functionality | mid |
speed range | 1-10 |
torque accuracy | +/- 15 % |
network frequency | 47.5...63 Hz |
height | 420 mm |
power dissipation in W | 626 W |
marking | CE |
width | 240 mm |
depth | 214 mm |
vibration resistance | 1.5 mm (f= 3-13 Hz) conforming to EN/IEC 60068-2-6, 1 gn (f= 13-200 Hz) conforming to EN/IEC 60068-2-8 |
operating altitude | <= 1000 m without derating, 1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m |
dielectric strength | 3535 V DC between earth and power terminals, 5092 V DC between control and power terminals |
IP degree of protection | IP21, IP20 on upper part without blanking plate on cover conforming to EN/IEC 61800-5-1, IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529, IP21 conforming to EN/IEC 61800-5-1, IP21 conforming to EN/IEC 60529, IP41 on upper part conforming to EN/IEC 61800-5-1, IP41 on upper part conforming to EN/IEC 60529 |
tightening torque | 0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES), 24 N.m, 212 lb.in (L1/R, L2/S, L3/T) |
product destination | asynchronous motors |
local signalling | 1 LED (red) for DC bus energized |
response time | FM 2 ms, tolerance +/- 0.5 ms for analog output(s), FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s), FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s), RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s) |
protection type | thermal protection: motor, short-circuit between motor phases: drive, line supply undervoltage: drive, break on the control circuit: drive, motor phase break: motor, overcurrent between output phases and earth: drive, overvoltages on the DC bus: drive, input phase breaks: drive, overheating protection: drive, against input phase loss: drive, with PTC probes: motor, thermal power stage: drive, against exceeding limit speed: drive, line supply overvoltage and undervoltage: drive |
connector type | 1 RJ45, 1 open style |
motor power kW | 22 kW |
supply frequency | 50...60 Hz - 5...5 % |
shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
network number of phases | 3 phases |
supply voltage limits | 323-528 V |
communication port protocol | Modbus, APOGEE FLN, BACnet, LonWorks, METASYS N2 |
communication service | read device identification (43), time out setting from 0.1 to 100 s, monitoring inhibitable, read holding registers (03) 2 words maximum, write multiple registers (16) 2 words maximum, write single register (06) |
type of cable | without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR, without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC, with UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC |
product specific application | pumps and fans in HVAC |
analogue output type | FM switch-configurable voltage 0...10 V DC, impedance: 7620 Ohm, resolution 10 bits, FM switch-configurable current 0...20 mA, impedance: 970 Ohm, resolution 10 bits |
maximum switching current | 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R), 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R), 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R), 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R) |
discrete output number | 2 |
noise level | 59.9 dB conforming to 86/188/EEC |
discrete input type | F programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm, R programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm, RES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm |
physical interface | 2-wire RS 485 |
assembly style | with heat sink |
transmission rate | 9600 bps or 19200 bps |
discrete input logic | positive logic (source) (F, R, RES), <= 5 V (state 0), >= 11 V (state 1), negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1) |
prospective line Isc | 22 kA |
acceleration and deceleration ramps | linear adjustable separately from 0.01 to 3200 s, automatic based on the load |
transmission frame | RTU |
data format | 8 bits, 1 stop, odd even or no configurable parity |
apparent power | 33.2 kVA at 380 V |
type of polarization | no impedance |
accuracy | +/- 0.6 % (VIA) for a temperature variation 60 °C, +/- 0.6 % (VIB) for a temperature variation 60 °C, +/- 1 % (FM) for a temperature variation 60 °C |
switching frequency | 6...16 kHz adjustable, 8...16 kHz with derating factor |
analogue input number | 2 |
motor slip compensation | adjustable, automatic whatever the load, not available in voltage/frequency ratio motor control |
regulation loop | adjustable PI regulator |
number of addresses | 1-247 |
linearity error | VIA: +/- 0.15 % of maximum value for input, VIB: +/- 0.15 % of maximum value for input, FM: +/- 0.2 % for output |
specific application | HVAC |
EMC filter | Class C2 EMC filter integrated |
sampling duration | 2 ms +/- 0.5 ms F discrete, 2 ms +/- 0.5 ms R discrete, 2 ms +/- 0.5 ms RES discrete, 3.5 ms +/- 0.5 ms VIA analog, 22 ms +/- 0.5 ms VIB analog |
option card | communication card for LonWorks |
frequency resolution | display unit: 0.1 Hz, analog input: 0.024/50 Hz |
supply | internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection, internal supply: 24 V DC (21-27 V), <200 A, protection type: overload and short-circuit protection |
air flow | 214 m3/h |
transient overtorque | 120-120 % of nominal motor torque +/- 10 % for 60 s |
speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn |