Schneider Electric

Altivar 320 variable speed drive, ATV320, 1.1 kW, 380…500 V, 3 phases, compact - ATV320U11N4C

In stock
SKU
ATV320U11N4C
37%
Special Price Rp 4.753.841 Regular Price Rp 7.545.780
Details

This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262.

The analogue output module provides 2 outputs with 11bit + sign and 12bit resolution.

It is an output module with a rated supply voltage of 24V DC and a current consumption of 70mA at 24V DC via external supply full load.

This product is capable of controlling variable speed drives or any device equipped with a current or voltage input.

There is an insulation between output and supply at 1500V AC, output and internal logic at 500V AC.

It is furnished with removable screw terminal for electrical connection with 5.08mm pitch adjustment for outputs.

It is an IP20 rated product.

Its dimensions are 23.6mm (Width) x 70mm (Depth) x 90mm (Height).

It weighs 0.115kg.

This product is certified by CE.

It meets EN/IEC 61131-2 and EN/IEC 61010-2-201 standards.

This module is compatible with Modicon M262, Modicon M241, Modicon M251 and Modicon M221 logic controller.

It supports top hat type TH35-15, top hat type TH35-7.5 rail conforming to IEC 60715 and plate or panel with fixing kit mount.

Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism.

A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers.

Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.

More Information
More Information
Attribute Value
SKU ATV320U11N4C
product certifications EAC, GOST, CE, RCM, ATEX, KC, NOM
ambient air temperature for storage -25-70 °C
overvoltage category III
pollution degree 2
ambient air temperature for operation -10-60 °C, -10-50 °C without derating, 50-60 °C with derating factor
maximum acceleration under vibratory load (during transport) 10 m/s² at 13...200 Hz
environmental class (during transport) class 2C3 according to EN 60721-3, class 2S1 according to EN 60721-3
supporting protocol for CAN true
number of inputs, bidirectional, not potential-free 0
nominal output current 3 A
power loss per device current dependent 40 W
housing material plastic
supporting protocol for Foundation Fieldbus false
range of product Altivar Machine ATV320
operating position vertical +/- 10 degree
product or component type Soft Starter & Variable Speed Drive
net weight 1.3 kg
mounting mode wall mount
range Altivar Machine ATV320
minimum switching current relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC
[Us] rated supply voltage 380...500 V, 380...500 V - 15...10 %
electromagnetic compatibility voltage dips and interruptions immunity test conforming to IEC 61000-4-11, electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
analogue input type AI1 voltage: 0...10 V DC, impedance: 30 kOhm, resolution 10 bits, AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits, AI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits
refresh time logic input (DI1...DI4): 8 ms, relay output (R1A, R1B, R1C): 2 ms, relay output (R2A, R2C): 2 ms
discrete output type open collector DQ+ 0-1 kHz 30 V DC 100 mA, open collector DQ- 0-1 kHz 30 V DC 100 mA
maximum output frequency 0.599 kHz
optical interface present false
number of HW interfaces serial RS422 0
line current 5.0 A at 380 V (heavy duty), 3.8 A at 500 V (heavy duty)
base load current at high overload 22 A
supporting protocol for AS-Interface Safety at Work false
asynchronous motor control profile voltage/frequency ratio, 5 points, flux vector control without sensor, standard, voltage/frequency ratio - Energy Saving, quadratic U/f, flux vector control without sensor - Energy Saving, voltage/frequency ratio, 2 points
number of HW interfaces industrial Ethernet 0
supporting protocol for SafetyBUS P false
variant standard version
with safety function Safe Speed Monitor (SSM) false
supporting protocol for INTERBUS-Safety false
maximum deflection under vibratory load (during transport) 3.5 mm at 2...13 Hz
number of HW interfaces USB 0
nominal output power 1.1 kW
supporting protocol for PROFINET CBA false
maximum associated fuse rating 0.4166666666666667 A
maximum acceleration under vibrational stress (during operation) 10 m/s² at 13...200 Hz
1 phase low current possible false
maximum acceleration under vibratory load (during storage) 10 m/s² at 13...200 Hz
number of HW interfaces serial RS232 0
supporting protocol for Data-Highway false
with safety function Safe Position (SP) false
analogue output number 1
number of inputs, potential-free 0
permitted relative humidity (during operation) class 3K5 according to EN 60721-3
brake chopper integrated true
with safety function Safe Stop 1 (SS1) true
nominal switching frequency 4 kHz
number of input phases 3
braking to standstill by DC injection
supporting protocol for KNX false
supporting protocol for PROFIsafe false
application in industrial area permitted true
computer port true
network frequency 50...60 Hz
height 142 mm
power dissipation in W fan: 40 W at 380 V, switching frequency 4 kHz
marking CE, ATEX, UL, CSA, EAC, RCM
width 105 mm
depth 158 mm
IP degree of protection IP20
protection type thermal protection: drive, short-circuit between motor phases: drive, overcurrent between output phases and earth: drive, input phase breaks: drive, overheating protection: drive
motor power kW 1.1 kW for heavy duty
NEMA degree of protection NEMA 1
communication port protocol Modbus serial, CANopen
product specific application complex machines
analogue output type software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits, software-configurable current AQ1: 0...20 mA impedance 800 Ohm, resolution 10 bits
maximum switching current relay output R1A, R1B, R1C on resistive load, cos phi = 1 : 3 A at 250 V AC, relay output R1A, R1B, R1C on resistive load, cos phi = 1 : 3 A at 30 V DC, relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC, relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC, relay output R2A, R2C on resistive load, cos phi = 1 : 5 A at 250 V AC, relay output R2A, R2C on resistive load, cos phi = 1 : 5 A at 30 V DC
discrete output number 3
discrete input type STO safe torque off, 24 V DC, impedance: 1.5 kOhm, DI1...DI6 logic inputs, 24 V DC (30 V), DI5 programmable as pulse input: 0-30 kHz, 24 V DC (30 V)
discrete input number 7
discrete input logic positive logic (source), negative logic (sink)
prospective line Isc 5 kA
supporting protocol for TCP/IP true
with safety function Safe brake management (SBC/SBT) false
maximum acceleration under shock load (during transport) 150 m/s² at 11 ms
acceleration and deceleration ramps linear, U, S, CUS, ramp switching, acceleration/deceleration ramp adaptation, acceleration/deceleration automatic stop with DC injection
encoder protocol RS 422
maximum deflection under vibratory load (during operation) 1.5 mm at 2...13 Hz
maximum acceleration under shock impact (during operation) 150 m/s² at 11 ms
number of HW interfaces PROFINET 0
maximum output voltage 500 V
4 quadrant operation possible true
supporting protocol for SERCOS false
supporting protocol for INTERBUS false
with safety function Safe torque off (STO) true
volume of cooling air 18 m3/h
relative symmetric network frequency tolerance 5 %
supporting protocol for ASI false
apparent power 3.3 kVA at 500 V (heavy duty)
supporting protocol for PROFIBUS true
relative symmetric mains voltage tolerance 10 %
EMC limit value (complied) true
with safety function Safe Direction (SDI) false
number of HW interfaces serial RS485 1
relay output type configurable relay logic R1A 1 NO electrical durability 100000 cycles, configurable relay logic R1B 1 NC electrical durability 100000 cycles, configurable relay logic R1C, configurable relay logic R2A 1 NO electrical durability 100000 cycles, configurable relay logic R2C
accuracy +/- 0.7 % AI1, AI2, AI3 for a temperature of -10...60 °C analog input, +/- 0.5 % AI1, AI2, AI3 for a temperature of 25 °C analog input, +/- 1 % AQ1 for a temperature of 25 °C analog output, +/- 2 % AQ1 for a temperature of -10...60 °C analog output
permitted relative humidity (during storage) class 1K5 according to EN 60721-3
switching frequency 2...16 kHz adjustable, 4...16 kHz with derating factor
application in domestic and commercial area permitted false
maximum input current 5 A
analogue input number 3
motor slip compensation automatic whatever the load, adjustable 0...300 %, not available in voltage/frequency ratio (2 or 5 points)
supporting protocol for PROFINET IO true
supporting protocol for MODBUS true
supporting protocol for DeviceNet Safety false
regulation loop adjustable PID regulator
operating element present true
permitted relative humidity (during transport) class 2K5 according to EN 60721-3
with safety function Safely Limited Position (SLP) false
method of access slave CANopen
with safety function Safe Operating Stop (SOS) false
supporting protocol for DeviceNet true
supporting protocol for EtherNet/IP true
number of HW interfaces parallel 0
linearity error AI1, AI2, AI3: +/- 0.2...0.5 % of maximum value for analog input, AQ1: +/- 0.3 % for analog output
with safety function Safe programmable logic false
supporting protocol for BACnet false
supporting protocol for LON false
with sft fct Safe Stop 2 (SS2) false
design of frequency changer U converter
power loss static current independent 40 W
supporting protocol for SUCONET false
EMC filter Class C2 EMC filter integrated
capacity of DC link 235 µF
maximum acceleration under shock load (during storage) 150 m/s² at 11 ms
number of HW interfaces serial TTY 0
number of HW interfaces other 1
with safety function Safely Limited Speed (SLS) true
number of output phases 3
ambient air transport temperature -25-70 °C
environmental class (during storage) class 1C3 according to EN 60721-3, class 1S2 according to EN 60721-3
environmental class (during operation) class 3C3 according to IEC 60721-3-3, class 3S2 according to IEC 60721-3-3
maximum deflection under vibratory load (during storage) 3.5 mm at 2...13 Hz
sampling duration 2 ms (AI1, AI2, AI3) - analog input, 2 ms (AQ1) - analog output
supporting protocol for other bus systems true
synchronous motor control profile vector control without sensor
option card communication module, Profibus DP V1, communication module, Profinet, communication module, DeviceNet, communication module, CANopen, communication module, EtherCAT, communication module, Ethernet Powerlink, communication module, Ethernet/IP
transient overtorque 170-200 % of nominal motor torque
speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn
PT. Telesindo Citra Sejahtera © 2021 All Rights Reserved.