Altivar 340 variable speed drive - 18kW- 400V - 3 phases - ATV340 - ATV340D18N4
This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262.
The analogue output module provides 2 outputs with 11bit + sign and 12bit resolution.
It is an output module with a rated supply voltage of 24V DC and a current consumption of 70mA at 24V DC via external supply full load.
This product is capable of controlling variable speed drives or any device equipped with a current or voltage input.
There is an insulation between output and supply at 1500V AC, output and internal logic at 500V AC.
It is furnished with removable screw terminal for electrical connection with 5.08mm pitch adjustment for outputs.
It is an IP20 rated product.
Its dimensions are 23.6mm (Width) x 70mm (Depth) x 90mm (Height).
It weighs 0.115kg.
This product is certified by CE.
It meets EN/IEC 61131-2 and EN/IEC 61010-2-201 standards.
This module is compatible with Modicon M262, Modicon M241, Modicon M251 and Modicon M221 logic controller.
It supports top hat type TH35-15, top hat type TH35-7.5 rail conforming to IEC 60715 and plate or panel with fixing kit mount.
Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism.
A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers.
Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.
Attribute | Value |
---|---|
SKU | ATV340D18N4 |
product certifications | EAC, CSA, UL, TÜV, CTick |
ambient air temperature for storage | -40-70 °C |
overvoltage category | class III |
pollution degree | 2, 2 conforming to EN/IEC 61800-5-1 |
ambient air temperature for operation | -15-60 °C, -15-50 °C without derating (vertical position), 50-60 °C with derating factor (vertical position) |
motor power hp | 30 hp for normal duty, 25 hp for heavy duty |
maximum acceleration under vibratory load (during transport) | 5 m/s² at 9...200 Hz |
environmental class (during transport) | class 2C3 according to EN 60721-3-2, class 2S1 according to EN 60721-3-2 |
supporting protocol for CAN | true |
continuous output current | 46 A at 4 kHz for normal duty, 39 A at 4 kHz for heavy duty |
number of inputs, bidirectional, not potential-free | 0 |
isolation | between power and control terminals |
nominal output current | 39 A |
power loss per device current dependent | 620 W |
housing material | plastic |
supporting protocol for Foundation Fieldbus | false |
output voltage | <= power supply voltage |
range of product | Altivar Machine ATV340 |
operating position | vertical +/- 10 degree |
product or component type | Soft Starter & Variable Speed Drive |
net weight | 10.2 kg |
mounting mode | cabinet mount |
standards | EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 60721-3, IEC 61508, IEC 13849-1, UL 618000-5-1, UL 508C |
range | Altivar Machine ATV340 |
minimum switching current | relay output R1B: 5 mA at 24 V DC, relay output R2C: 5 mA at 24 V DC |
insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
power range | 15-25 kW at 380-440 V 3 phases, 15-25 kW at 480-500 V 3 phases |
motor starter type | variable speed drive |
[Us] rated supply voltage | 380...480 V, 380...480 V - 15...10 % |
electromagnetic compatibility | electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
analogue input type | AI1 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits, AI1 software-configurable temperature probe or water level sensor, AI1 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits, AI2 software-configurable voltage: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits |
refresh time | relay output (R1, R2): 5 ms (+/- 0.5 ms) |
electrical connection | control: screw terminal 0.2...2.5 mm²/AWG 24...AWG 12, line side: screw terminal 10...25 mm²/AWG 8...AWG 3, DC bus: screw terminal 10...25 mm²/AWG 8...AWG 3, motor: screw terminal 6...25 mm²/AWG 8...AWG 3, screw terminal, clamping capacity: 0.2...2.5 mm² for control, screw terminal, clamping capacity: 10...25 mm² for line side, screw terminal, clamping capacity: 10...25 mm² for DC bus, screw terminal, clamping capacity: 6...25 mm² for motor |
discrete output type | programmable output DQ1, DQ2 30 V DC 100 mA |
maximum output frequency | 0.599 kHz |
optical interface present | false |
number of HW interfaces serial RS422 | 0 |
line current | 43.4 A at 380 V (normal duty), 35.0 A at 480 V (normal duty), 54.7 A at 380 V (heavy duty), 43.4 A at 480 V (heavy duty), 54.7 A at 380 V without line choke (heavy duty), 43.4 A at 480 V without line choke (heavy duty), 49.9 A at 380 V with external line choke (normal duty), 40.2 A at 480 V with external line choke (normal duty), 54.5 A at 480 V with external line choke (heavy duty), 43.5 A at 380 V with external line choke (heavy duty) |
base load current at high overload | 39 A |
speed drive output frequency | 0.1-599 Hz |
supporting protocol for AS-Interface Safety at Work | false |
asynchronous motor control profile | variable torque standard, constant torque standard, optimized torque mode |
number of HW interfaces industrial Ethernet | 0 |
supporting protocol for SafetyBUS P | false |
variant | standard version |
with safety function Safe Speed Monitor (SSM) | false |
relay output number | 2 |
supporting protocol for INTERBUS-Safety | false |
maximum deflection under vibratory load (during transport) | 1.5 mm at 2...9 Hz |
number of HW interfaces USB | 0 |
nominal output power | 18.5 W |
supporting protocol for PROFINET CBA | true |
maximum associated fuse rating | 100 A |
maximum acceleration under vibrational stress (during operation) | 5 m/s² at 9...200 Hz |
1 phase low current possible | false |
maximum acceleration under vibratory load (during storage) | 5 m/s² at 9...200 Hz |
maximum transient current | 50.6 A during 60 s (normal duty), 59 A during 60 s (heavy duty), 62.1 A during 2 s (normal duty), 70 A during 2 s (heavy duty) |
number of HW interfaces serial RS232 | 0 |
input compatibility | DI1...DI5: discrete input level 1 PLC conforming to EN/IEC 61131-2, PTI: pulse input level 1 PLC conforming to IEC 65A-68, STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2 |
supporting protocol for Data-Highway | false |
with safety function Safe Position (SP) | false |
analogue output number | 2 |
number of inputs, potential-free | 0 |
permitted relative humidity (during operation) | class 3K5 according to EN 60721-3 |
brake chopper integrated | true |
with safety function Safe Stop 1 (SS1) | true |
nominal switching frequency | 4 kHz |
number of input phases | 3 |
braking to standstill | by DC injection |
supporting protocol for KNX | false |
supporting protocol for PROFIsafe | false |
application in industrial area permitted | true |
computer port | true |
network frequency | 50...60 Hz |
height | 385 mm |
power dissipation in W | natural convection: 21 W at 380 V, switching frequency 4 kHz (heavy duty), forced convection: 410 W at 380 V, switching frequency 4 kHz (heavy duty), natural convection: 23 W at 380 V, switching frequency 4 kHz (normal duty), forced convection: 464 W at 380 V, switching frequency 4 kHz (normal duty) |
marking | CE |
width | 180 mm |
depth | 249 mm |
vibration resistance | 1.5 mm peak to peak (f= 2-19 Hz) conforming to EN/IEC 60721-3-3 class 3M3, 1 gn (f= 9-200 Hz) conforming to EN/IEC 60721-3-3 class 3M3 |
operating altitude | <= 3000 m with current derating above 1000m |
IP degree of protection | IP20 |
protection type | thermal protection: motor, safe torque off: motor, motor phase loss: motor, thermal protection: drive, safe torque off: drive, overheating: drive, overcurrent: drive, output overcurrent between motor phase and earth: drive, output overcurrent between motor phases: drive, short-circuit between motor phase and earth: drive, short-circuit between motor phases: drive, motor phase loss: drive, DC Bus overvoltage: drive, line supply overvoltage: drive, line supply undervoltage: drive, input supply loss: drive, exceeding limit speed: drive, break on the control circuit: drive |
connector type | 1 RJ45, connector(s)1 x RJ45, Modbus serial on front face, connector(s)1 x RJ45, Modbus serial for HMI on front face |
motor power kW | 22 kW for normal duty, 18.5 kW for heavy duty |
supply frequency | 50...60 Hz +/- 5 % |
shock resistance | 15 gn for 11 ms, class 3M3 conforming to EN/IEC 60721-3-3 |
network number of phases | 3 phases |
NEMA degree of protection | not applicable |
communication port protocol | Modbus serial |
product specific application | machine |
analogue output type | software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits, software-configurable current AQ1: 0...20 mA impedance 500 Ohm, resolution 10 bits |
maximum switching current | relay output R1C on resistive load, cos phi = 1 : 3 A at 250 V AC, relay output R1C on resistive load, cos phi = 1 : 3 A at 30 V DC, relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC, relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC, relay output R2C on resistive load, cos phi = 1 : 5 A at 250 V AC, relay output R2C on resistive load, cos phi = 1 : 5 A at 30 V DC, relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC, relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
discrete output number | 2 |
noise level | 56.7 dB |
discrete input type | PTI programmable as pulse input: 0-30 kHz, 24 V DC (30 V), DI1...DI5 safe torque off, 24 V DC (30 V), impedance: 3.5 kOhm, programmable |
physical interface | 2-wire RS 485 |
type of cooling | forced convection |
discrete input number | 5 |
assembly style | with heat sink |
transmission rate | 4.8 kbit/s, 9.6 kbit/s, 19.2 kbit/s, 38.4 kbit/s |
discrete input logic | positive logic (source) (DI1...DI5), < 5 V (state 0), > 11 V (state 1), negative logic (sink) (DI1...DI5), > 16 V (state 0), < 10 V (state 1), positive logic (source) (PTI), < 0.6 V (state 0), > 2.5 V (state 1), positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1), 16 preset speeds |
prospective line Isc | 22 kA |
supporting protocol for TCP/IP | false |
with safety function Safe brake management (SBC/SBT) | true |
maximum acceleration under shock load (during transport) | 70 m/s² at 22 ms |
acceleration and deceleration ramps | S, U or customized, linear adjustable separately from 0.01...9999 s |
encoder protocol | 1 Vpp, EnDat 2.2, resolver, RS 422, SSI 24V, SSI 5V, TTL/HTL |
maximum deflection under vibratory load (during operation) | 1.5 mm at 2...9 Hz |
maximum acceleration under shock impact (during operation) | 70 m/s² at 22 ms |
number of HW interfaces PROFINET | 0 |
maximum output voltage | 480 V |
transmission frame | RTU |
4 quadrant operation possible | true |
supporting protocol for SERCOS | false |
supporting protocol for INTERBUS | false |
with safety function Safe torque off (STO) | true |
volume of cooling air | 128 m3/h |
data format | 8 bits, configurable odd, even or no parity |
relative symmetric network frequency tolerance | 5 % |
input/output type | programmable as logic input/output DQ1: 0-1 kHz, <= 30 V DC, 100 mA, programmable as logic input/output DQ2: 0-1 kHz, <= 30 V DC, 100 mA |
supporting protocol for ASI | false |
apparent power | 33.4 kVA at 480 V (normal duty), 36.1 kVA at 480 V (heavy duty) |
supporting protocol for PROFIBUS | true |
relative symmetric mains voltage tolerance | 10 % |
EMC limit value (complied) | true |
base load current at low overload | 46 A |
with safety function Safe Direction (SDI) | false |
number of HW interfaces serial RS485 | 1 |
type of polarization | no impedance |
relay output type | relay outputs R1A, relay outputs R1C electrical durability 100000 cycles, relay outputs R2A, relay outputs R2C electrical durability 100000 cycles |
accuracy | +/- 0.6 % AI1, AI2 for a temperature variation 60 °C analog input, +/- 1 % AQ1 for a temperature variation 60 °C analog output |
permitted relative humidity (during storage) | class 1K5 according to EN 60721-3 |
switching frequency | 2...16 kHz adjustable, 4...16 kHz with derating factor |
application in domestic and commercial area permitted | false |
maximum input current | 54.7 A |
analogue input number | 2 |
motor slip compensation | can be suppressed, adjustable, not available in permanent magnet motor law, automatic whatever the load |
supporting protocol for PROFINET IO | true |
supporting protocol for MODBUS | true |
supporting protocol for DeviceNet Safety | false |
regulation loop | adjustable PID regulator |
operating element present | true |
permitted relative humidity (during transport) | class 2K5 according to EN 60721-3 |
with safety function Safely Limited Position (SLP) | false |
method of access | slave Modbus RTU |
with safety function Safe Operating Stop (SOS) | false |
supporting protocol for DeviceNet | false |
supporting protocol for EtherNet/IP | false |
number of addresses | 1-247 |
number of HW interfaces parallel | 0 |
safety function | STO (safe torque off) SIL 3 |
linearity error | AI1, AI2: +/- 0.15 % of maximum value for analog input, AQ1: +/- 0.2 % for analog output |
with safety function Safe programmable logic | false |
specific application | machine |
supporting protocol for BACnet | false |
supporting protocol for LON | false |
with sft fct Safe Stop 2 (SS2) | false |
design of frequency changer | U converter |
power loss static current independent | 19 W |
supporting protocol for SUCONET | false |
EMC filter | class C3 EMC filter integrated |
capacity of DC link | 2250 µF |
maximum acceleration under shock load (during storage) | 70 m/s² at 22 ms |
number of HW interfaces serial TTY | 0 |
number of HW interfaces other | 0 |
with safety function Safely Limited Speed (SLS) | true |
number of output phases | 3 |
ambient air transport temperature | -40-70 °C |
environmental class (during storage) | class 1C3 according to EN 60721-3-1, class 1S2 according to EN 60721-3-1 |
environmental class (during operation) | class 3C3 according to IEC 60721-3-3, class 3S3 according to IEC 60721-3-3 |
maximum deflection under vibratory load (during storage) | 1.5 mm at 2...9 Hz |
sampling duration | 2 ms +/- 0.5 ms (DI1...DI5) - discrete input, 5 ms +/- 1 ms (PTI) - pulse input, 1 ms +/- 1 ms (AI1, AI2) - analog input, 5 ms +/- 1 ms (AQ1) - analog output, 2 ms +/- 0.5 ms (DQ1, DQ2) - discrete input/output |
supporting protocol for other bus systems | true |
synchronous motor control profile | reluctance motor, permanent magnet motor |
option card | communication module, Profibus DP V1, communication module, Profinet, communication module, DeviceNet, communication module, CANopen, communication module, EtherCAT |