Altivar Process ATV600 variable speed drive ATV630 - 250kW/400HP - 380...480V - IP00 - ATV630C25N4
This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262.
The analogue output module provides 2 outputs with 11bit + sign and 12bit resolution.
It is an output module with a rated supply voltage of 24V DC and a current consumption of 70mA at 24V DC via external supply full load.
This product is capable of controlling variable speed drives or any device equipped with a current or voltage input.
There is an insulation between output and supply at 1500V AC, output and internal logic at 500V AC.
It is furnished with removable screw terminal for electrical connection with 5.08mm pitch adjustment for outputs.
It is an IP20 rated product.
Its dimensions are 23.6mm (Width) x 70mm (Depth) x 90mm (Height).
It weighs 0.115kg.
This product is certified by CE.
It meets EN/IEC 61131-2 and EN/IEC 61010-2-201 standards.
This module is compatible with Modicon M262, Modicon M241, Modicon M251 and Modicon M221 logic controller.
It supports top hat type TH35-15, top hat type TH35-7.5 rail conforming to IEC 60715 and plate or panel with fixing kit mount.
Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism.
A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers.
Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.
Attribute | Value |
---|---|
SKU | ATV630C25N4 |
product certifications | CSA, UL, TÜV |
relative humidity | 5-95 % without condensation conforming to IEC 60068-2-3 |
ambient air temperature for storage | -25-70 °C |
pollution degree | 2 conforming to EN/IEC 61800-5-1 |
ambient air temperature for operation | -10-40 °C (without derating), 40-60 °C (with derating factor) |
motor power hp | 400 hp normal duty, 300 hp heavy duty |
continuous output current | 481 A at 2.5 kHz for normal duty, 387 A at 2.5 kHz for heavy duty |
isolation | between power and control terminals |
output frequency | 1.0E-4-0.5 kHz |
output voltage | <= power supply voltage |
range of product | Altivar Process ATV600 |
operating position | vertical +/- 10 degree |
product or component type | Soft Starter & Variable Speed Drive |
net weight | 203 kg |
mounting mode | wall mount |
standards | EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 60721-3, IEC 61508, IEC 13849-1, UL 508C, environment 2 category C3 EN/IEC 61800-3, environment 1 category C2 EN/IEC 61800-3, IEC 61000-3-12 |
device short name | ATV630 |
range | Altivar Process ATV630 |
minimum switching current | relay output R1, R2, R3: 5 mA at 24 V DC |
insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
power range | 250-500 kW at 380-440 V 3 phases, 250-500 kW at 480-500 V 3 phases |
motor starter type | variable speed drive |
[Us] rated supply voltage | 380...480 V - 15...10 % |
electromagnetic compatibility | electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
analogue input type | AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits, AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits |
refresh time | relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
electrical connection | control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16, line side: screw terminal 4 x 185 mm²/3 x 350 kcmil, motor: screw terminal 4 x 185 mm²/3 x 350 kcmil |
line current | 451 A at 380 V (normal duty), 366 A at 480 V (normal duty), 365 A at 380 V (heavy duty), 301 A at 480 V (heavy duty) |
speed drive output frequency | 0.1-599 Hz |
asynchronous motor control profile | variable torque standard, constant torque standard, optimized torque mode |
variant | standard version |
exchange mode | half duplex, full duplex, autonegotiation Ethernet/Modbus TCP |
relay output number | 3 |
maximum transient current | 581 A during 60 s (heavy duty), 529 A during 60 s (normal duty) |
input compatibility | STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2, DI1...DI6: discrete input level 1 PLC conforming to EN/IEC 61131-2, DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68 |
analogue output number | 2 |
nominal switching frequency | 2.5 kHz |
braking to standstill | by DC injection |
maximum THDI | <48 % full load conforming to IEC 61000-3-12 |
height | 1195 mm |
power dissipation in W | natural convection: 606 W at 380 V, switching frequency 2.5 kHz, forced convection: 5773 W |
marking | CE |
width | 598 mm |
depth | 380 mm |
vibration resistance | 1.5 mm peak to peak (f= 2-13 Hz) conforming to IEC 60068-2-6, 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6 |
operating altitude | <= 1000 m without derating, 1000...3000 m with current derating 1 % per 100 m |
IP degree of protection | IP21, IP00 conforming to IEC 61800-5-1, IP00 conforming to IEC 60529, IP21 (with kit VW3A9113) conforming to IEC 61800-5-1, IP21 (with kit VW3A9113) conforming to IEC 60529 |
product destination | asynchronous motors, synchronous motors |
local signalling | 1 LED (red) for presence of voltage, 3 LEDs for local diagnostic, 3 LEDs (dual colour) for embedded communication status, 4 LEDs (dual colour) for communication module status |
protection type | thermal protection: motor, safe torque off: motor, thermal protection: drive, safe torque off: drive, overheating: drive, line supply overvoltage: drive, line supply undervoltage: drive, break on the control circuit: drive, motor phase break: motor, overcurrent between output phases and earth: drive, overload of output voltage: drive, short-circuit protection: drive, motor phase break: drive, overvoltages on the DC bus: drive, line supply phase loss: drive, overspeed: drive |
connector type | RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP, RJ45 (on the remote graphic terminal) for Modbus serial |
motor power kW | 250 kW (normal duty), 220 kW (heavy duty) |
supply frequency | 50...60 Hz - 5...5 % |
shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
communication port protocol | Modbus TCP, Modbus serial, Ethernet |
product specific application | process and utilities |
analogue output type | software-configurable voltage AO1, AO2: 0...10 V DC impedance 470 Ohm, resolution 10 bits, software-configurable current AO1, AO2: 0...20 mA, resolution 10 bits |
maximum switching current | relay output R1, R2, R3 on resistive load, cos phi = 1 : 3 A at 250 V AC, relay output R1, R2, R3 on resistive load, cos phi = 1 : 3 A at 30 V DC, relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC, relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
noise level | 68 dB conforming to 86/188/EEC |
discrete input type | DI5, DI6 programmable as pulse input: 0-30 kHz, 24 V DC (<= 30 V), DI1...DI6 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm, STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm |
type of cooling | forced convection |
discrete input number | 8 |
discrete input logic | positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1), 16 preset speeds, positive logic (source) (DI1...DI6), < 5 V (state 0), > 11 V (state 1), negative logic (sink) (DI1...DI6), > 16 V (state 0), < 10 V (state 1), positive logic (source) (DI5, DI6), < 0.6 V (state 0), > 2.5 V (state 1) |
prospective line Isc | 50 kA |
acceleration and deceleration ramps | linear adjustable separately from 0.01...9999 s |
volume of cooling air | 1260 m3/h |
apparent power | 279 kVA at 480 V (normal duty), 229 kVA at 480 V (heavy duty) |
relay output type | configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles, configurable relay logic R2: sequence relay NO electrical durability 100000 cycles, configurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input, +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output |
switching frequency | 2.5...8 kHz with derating factor, 2...8 kHz adjustable |
analogue input number | 3 |
motor slip compensation | can be suppressed, adjustable, not available in permanent magnet motor law, automatic whatever the load |
method of access | slave Modbus TCP |
number of addresses | 1-247 for Modbus serial |
safety function | STO (safe torque off) SIL 3 |
linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input, AO1, AO2: +/- 0.2 % for analog output |
specific application | utility |
EMC filter | integrated with 50 m conforming to EN/IEC 61800-3 category C3 |
sampling duration | 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input, 2 ms +/- 0.5 ms (DI1...DI4) - discrete input, 5 ms +/- 1 ms (DI5, DI6) - discrete input, 10 ms +/- 1 ms (AO1) - analog output |
synchronous motor control profile | permanent magnet motor, synchronous reluctance motor |
option card | slot A: communication module, Profibus DP V1, slot A: communication module, Profinet, slot A: communication module, DeviceNet, slot A: communication module, Modbus TCP/EtherNet/IP, slot A: communication module, CANopen daisy chain RJ45, slot A: communication module, CANopen SUB-D 9, slot A: communication module, CANopen screw terminals, slot A/slot B: digital and analog I/O extension module, slot A/slot B: output relay extension module, slot A: communication module, Ethernet IP/Modbus TCP/MD-Link, communication module, BACnet MS/TP, communication module, Ethernet Powerlink |
frequency resolution | display unit: 0.1 Hz, analog input: 0.012/50 Hz |
supply | external supply for digital inputs: 24 V DC (19-30 V), <1.25 mA, protection type: overload and short-circuit protection, internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection, internal supply for digital inputs and STO: 24 V DC (21-27 V), <200 mA, protection type: overload and short-circuit protection |
permissible temporary current boost | 1.1 x In during 60 s (normal duty), 1.5 x In during 60 s (heavy duty) |