Schneider Electric

Altivar Process ATV900 variable speed drive - ATV930 - 15kW - 400/480V - with braking unit - IP21 - ATV930D15N4

Out of stock
SKU
ATV930D15N4
40%
Special Price Rp 32.046.242 Regular Price Rp 53.410.403
Details

This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262.

The analogue output module provides 2 outputs with 11bit + sign and 12bit resolution.

It is an output module with a rated supply voltage of 24V DC and a current consumption of 70mA at 24V DC via external supply full load.

This product is capable of controlling variable speed drives or any device equipped with a current or voltage input.

There is an insulation between output and supply at 1500V AC, output and internal logic at 500V AC.

It is furnished with removable screw terminal for electrical connection with 5.08mm pitch adjustment for outputs.

It is an IP20 rated product.

Its dimensions are 23.6mm (Width) x 70mm (Depth) x 90mm (Height).

It weighs 0.115kg.

This product is certified by CE.

It meets EN/IEC 61131-2 and EN/IEC 61010-2-201 standards.

This module is compatible with Modicon M262, Modicon M241, Modicon M251 and Modicon M221 logic controller.

It supports top hat type TH35-15, top hat type TH35-7.5 rail conforming to IEC 60715 and plate or panel with fixing kit mount.

Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism.

A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers.

Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.

More Information
More Information
Attribute Value
SKU ATV930D15N4
product certifications CSA, UL, TÜV
relative humidity 5-95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for storage -40-70 °C
pollution degree 2 conforming to EN/IEC 61800-5-1
ambient air temperature for operation -15-50 °C (without derating), 50-60 °C (with derating factor)
environmental characteristic chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3, dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
motor power hp 20 hp normal duty, 15 hp heavy duty
continuous output current 31.7 A at 4 kHz for normal duty, 23.5 A at 4 kHz for heavy duty
isolation between power and control terminals
output voltage <= power supply voltage
range of product Altivar Process ATV900
operating position vertical +/- 10 degree
product or component type Soft Starter & Variable Speed Drive
net weight 13.6 kg
mounting mode wall mount
standards EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 60721-3, IEC 61508, IEC 13849-1, UL 508C, environment 2 category C3 EN/IEC 61800-3, environment 1 category C2 EN/IEC 61800-3, IEC 61000-3-12
device short name ATV930
range Altivar Process ATV930
minimum switching current relay output R1, R2, R3: 5 mA at 24 V DC
insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
power range 15-25 kW at 380-440 V 3 phases, 15-25 kW at 480-500 V 3 phases
motor starter type variable speed drive
[Us] rated supply voltage 380...480 V - 15...10 %
electromagnetic compatibility electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
analogue input type AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits, AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits
refresh time relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
electrical connection line side: screw terminal 10...16 mm²/AWG 8...AWG 6, motor: screw terminal 10...16 mm²/AWG 8...AWG 6, control: screw terminal 0.5...1.5 mm²/AWG 20...AWG 16, DC bus: screw terminal 10...16 mm²/AWG 8...AWG 6
discrete output type logic output DQ+ 0-1 kHz <= 30 V DC 100 mA, programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA, logic output DQ- 0-1 kHz <= 30 V DC 100 mA
line current 27 A at 380 V (normal duty), 23.3 A at 480 V (normal duty), 20.6 A at 380 V (heavy duty), 18.1 A at 480 V (heavy duty)
speed drive output frequency 0.1-599 Hz
asynchronous motor control profile variable torque standard, constant torque standard, optimized torque mode
variant standard version, with braking chopper
exchange mode half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
relay output number 3
maximum transient current 35.3 A during 60 s (heavy duty), 38 A during 60 s (normal duty)
input compatibility STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2, DI1...DI8: discrete input level 1 PLC conforming to EN/IEC 61131-2, DI7, DI8: pulse input level 1 PLC conforming to IEC 65A-68
analogue output number 2
nominal switching frequency 4 kHz
braking to standstill by DC injection
maximum THDI <48 % from 80...100 % of load conforming to IEC 61000-3-12
height 545.9 mm
power dissipation in W natural convection: 59 W at 380 V, switching frequency 4 kHz, forced convection: 366 W at 380 V, switching frequency 4 kHz
marking CE
width 211 mm
depth 235 mm
vibration resistance 1.5 mm peak to peak (f= 2-13 Hz) conforming to IEC 60068-2-6, 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6
operating altitude <= 1000 m without derating, 1000...4800 m with current derating 1 % per 100 m
IP degree of protection IP21, IP21 conforming to IEC 61800-5-1, IP21 conforming to IEC 60529
device application industrial application
product destination asynchronous motors, synchronous motors
local signalling local diagnostic: 3 LED (mono/dual colour), embedded communication status: 5 LED (dual colour), communication module status: 2 LED (dual colour), presence of voltage: 1 LED (red)
protection type thermal protection: motor, safe torque off: motor, thermal protection: drive, safe torque off: drive, overheating: drive, line supply overvoltage: drive, line supply undervoltage: drive, break on the control circuit: drive, motor phase break: motor, overcurrent between output phases and earth: drive, overload of output voltage: drive, short-circuit protection: drive, motor phase break: drive, overvoltages on the DC bus: drive, line supply phase loss: drive, overspeed: drive
connector type 2 RJ45 for Ethernet IP/Modbus TCP on the control block, 1 RJ45 for Modbus serial on the control block
motor power kW 15 kW (normal duty), 11 kW (heavy duty)
supply frequency 50...60 Hz +/- 5 %
shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
network number of phases 3 phases
communication port protocol Ethernet/IP, Modbus TCP, Modbus serial
analogue output type software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits, software-configurable current AQ1, AQ2: 0...20 mA impedance 500 Ohm, resolution 10 bits
maximum switching current relay output R1 on resistive load, cos phi = 1 : 3 A at 250 V AC, relay output R1 on resistive load, cos phi = 1 : 3 A at 30 V DC, relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC, relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC, relay output R2, R3 on resistive load, cos phi = 1 : 5 A at 250 V AC, relay output R2, R3 on resistive load, cos phi = 1 : 5 A at 30 V DC, relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC, relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
discrete output number 2
noise level 59.5 dB conforming to 86/188/EEC
discrete input type STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm, DI1...DI8 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm, DI7, DI8 programmable as pulse input: 0-30 kHz, 24 V DC (<= 30 V)
physical interface 2-wire RS 485 for Modbus serial
type of cooling forced convection
discrete input number 10
transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial, 10/100 Mbit/s for Ethernet IP/Modbus TCP
discrete input logic positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1), 16 preset speeds, positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1), negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1), positive logic (source) (DI7, DI8), < 0.6 V (state 0), > 2.5 V (state 1)
prospective line Isc 50 kA
acceleration and deceleration ramps linear adjustable separately from 0.01...9999 s
transmission frame RTU for Modbus serial
volume of cooling air 215 m3/h
data format 8 bits, configurable odd, even or no parity for Modbus serial
apparent power 19.4 kVA at 480 V (normal duty), 15 kVA at 480 V (heavy duty)
type of polarization no impedance for Modbus serial
relay output type configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles, configurable relay logic R2: sequence relay NO electrical durability 1000000 cycles, configurable relay logic R3: sequence relay NO electrical durability 1000000 cycles
accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input, +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
switching frequency 2...16 kHz adjustable, 4...16 kHz with derating factor
analogue input number 3
motor slip compensation can be suppressed, adjustable, not available in permanent magnet motor law, automatic whatever the load
method of access slave Modbus TCP
number of addresses 1-247 for Modbus serial
safety function STO (safe torque off) SIL 3
linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input, AQ1, AQ2: +/- 0.2 % for analog output
specific application process
EMC filter integrated with 50 m conforming to EN/IEC 61800-3 category C2, integrated with 150 m conforming to EN/IEC 61800-3 category C3
sampling duration 2 ms +/- 0.5 ms (DI1...DI8) - discrete input, 5 ms +/- 1 ms (DI7, DI8) - pulse input, 1 ms +/- 1 ms (AI1, AI2, AI3) - analog input, 5 ms +/- 1 ms (AQ1, AQ2) - analog output
synchronous motor control profile permanent magnet motor, synchronous reluctance motor
option card slot A: communication module for Profibus DP V1, slot A: communication module for Profinet, slot A: communication module for DeviceNet, slot A: communication module for EtherCAT, slot A: communication module for CANopen daisy chain RJ45, slot A: communication module for CANopen SUB-D 9, slot A: communication module for CANopen screw terminals, slot A/slot B/slot C: digital and analog I/O extension module, slot A/slot B/slot C: output relay extension module, slot B: 5/12 V digital encoder interface module, slot B: analog encoder interface module, slot B: resolver encoder interface module, communication module for Ethernet Powerlink
frequency resolution display unit: 0.1 Hz, analog input: 0.012/50 Hz
supply external supply for digital inputs: 24 V DC (19-30 V), <1.25 mA, protection type: overload and short-circuit protection, internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection, internal supply for digital inputs and STO: 24 V DC (21-27 V), <200 mA, protection type: overload and short-circuit protection
degree of protection UL type 1 conforming to UL 508C
PT. Telesindo Citra Sejahtera © 2021 All Rights Reserved.