C60 auxiliary contact - 1 OC or 1 SD or 1 SDE or 1 SDV low level - 29452
It is a single low-level auxiliary contact that provides all the different indications remotely for Compact NSX, Compact NS, PowerPact Multistandard and EasyPact CVS circuit breakers.
Remote status information are ON/OFF (OF), trip indication (SD) and fault-trip indication (SDE) for all circuit breakers types.
The remote status information for trip indication due to an earth fault (SDV) is used for Compact NSX and PowerPact Multistandard.
The contacts are installed in the device in dedicated slots.
This auxiliary contact is a common point changeover type contact with 1 normally open contact and 1 normally closed contact.
The rated current is 5A and the minimum load is 1MA at 4 VDC for utilization categories AC12/AC15/DC12/DC14.
One device embeds 5 auxiliaries contact type.
It complies with IEC 60947-5-1 standard.
Attribute | Value |
---|---|
SKU | 29452 |
range of product | ComPact NSX100...250, ComPact NSX400...630, ComPact NSX100...250 DC, ComPact NSX100...250 DC PV, ComPact NSX400...630 DC, ComPact NSX400...630 DC PV, ComPact NS630b...1600, ComPact NS1600b...3200 |
product or component type | MCCB |
mounting mode | clip-on |
device short name | OF, SD, SDE, SDV |
range | Aksesoris |
[Ie] rated operational current | DC-12: 2.5 A at 48 V DC, DC-12: 0.6 A at 110 V DC, DC-12: 0.3 A at 250 V DC, DC-14: 1 A at 24 V DC, DC-14: 0.2 A at 48 V DC, DC-14: 0.05 A at 110 V DC, DC-14: 0.03 A at 250 V DC, AC-12: 5 A at 24 V AC 50/60 Hz, AC-12: 5 A at 48 V AC 50/60 Hz, AC-12: 5 A at 480 V AC 50/60 Hz, AC-12: 5 A at 110 V AC 50/60 Hz, AC-12: 5 A at 220/240 V AC 50/60 Hz, AC-12: 5 A at 380/440 V AC 50/60 Hz, AC-15: 3 A at 24 V AC 50/60 Hz, AC-15: 3 A at 48 V AC 50/60 Hz, AC-15: 2.5 A at 110 V AC 50/60 Hz, AC-15: 2 A at 220/240 V AC 50/60 Hz, AC-15: 1.5 A at 380/440 V AC 50/60 Hz, AC-15: 1 A at 480 V AC 50/60 Hz, DC-12: 5 A at 24 V DC |
range compatibility | ComPact NSX, EasyPact CVS, PowerPact Multistandard, ComPact NSX DC, ComPact NS630b...1600, ComPact NS1600b...3200, Compact INS, Compact INV |
accessory / separate part category | spare part for Compact NS630b...1600, spare part for Compact NS1600b...3200 |
[Ith] conventional free air thermal current | 5 A |
auxiliary contacts type | low level |
fault type | general electric fault |
device application | breaker status monitoring |
local signalling | ON/OFF indication for open/close, trip indicator for relay trip indicator, fault trip for electrical fault |
minimum load | 1 mA at 4 V DC |
signal contacts composition | 1 NO/NC |