Schneider Electric

Compact NS > 630A circuit breaker NS1000N - Micrologic 5.0 - 1000 A - 4 poles 4t - 33561

Out of stock
SKU
33561
50%
Special Price Rp 32.424.560 Regular Price Rp 64.849.119
More Information
More Information
Attribute Value
SKU 33561
product certifications ASEFA, ASTA
relative humidity 0-95 %
ambient air temperature for storage -50-85 °C
pollution degree 3 conforming to IEC 60947
ambient air temperature for operation -25-70 °C
upside connection front
[Icw] rated short-time withstand current 19.2 kA 1 s conforming to IEC 60947-2
range of product ComPact NS630b...1600
product or component type MCCB
net weight 18 kg
mounting mode fixed
standards EN/IEC 60947-2
earth-leakage protection without
mechanical durability 10000 cycles
device short name Compact NS1000N
breaking capacity 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2, 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
trip unit technology electronic
range ComPact NS
IK degree of protection IK07 conforming to EN 50102
[Ics] rated service breaking capacity 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, 30 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2, 40 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
trip unit name Micrologic 5.0
trip unit rating 1000-1000 A at 50 °C
breaking capacity code N 50 kA 415 V AC
downside connection front
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
product name ComPact NS
short-time delay adjustment type adjustable
thermal memory 20 mn
network frequency 50/60 Hz
height 327 mm
mounting support backplate
compatibility code NS1000
width 280 mm
depth 147 mm
operating altitude 0...2000 m without derating, 2000 m...5000 m with derating
IP degree of protection IP40 conforming to IEC 60529
[In] rated current 1000 A at 50 °C
network type AC
poles description 4P
electrical durability 2000 cycles at 690 V In, 4000 cycles at 690 V In/2, 5000 cycles at 440 V In, 6000 cycles at 440 V In/2
device application distribution
control type toggle, rotary handle
[Ue] rated operational voltage 690 V AC 50/60 Hz
local signalling 4 LEDs (red) for fault indication, 1 LED (yellow) for overload
protection type L : for overload protection (long time), I : for instantaneous short-circuit protection, S : for short time short-circuit protection
utilisation category category B
neutral protection setting no protection (3d), 1 x Ir (4d), 0.5 x Ir (3d + N/2)
connection pitch 70 mm
[Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolation yes conforming to EN/IEC 60947-2
protected poles description 4d
auxiliary contact composition 1 NO/NC
neutral position left
long time pick-up adjustment range 0.4...1 x In
long time pick-up adjustment type Ir adjustable 9 settings
instantaneous pick-up adjustment range 2...15 x In, off
long time delay adjustment type adjustable 9 settings
instantaneous pick-up adjustment type Ii adjustable
power losses 22 W
[Isd] short-time pick-up adjustment range 1.5...10 x Ir
[tr] long-time delay adjustment range 12.5-600 s at 1.5 x Ir, 0.5-24 s at 6 x Ir, 0.7-16.6 s at 7.2 x Ir
trip unit protection functions LSI
short-time pick-up adjustment type Isd adjustable 9 settings
[tsd] short-time delay adjustment range 0.1-0.4 s I²t=on, 0-0.4 s I²t=off
PT. Telesindo Citra Sejahtera © 2025 All Rights Reserved.