Compact NSX <630 auxiliary contact - 1 OC or 1 SD or 1 SDE or 1 SDV - 29450

In stock
SKU
29450
50%
Special Price Rp 325.841 Regular Price Rp 651.681
Details

It is a single standard auxiliary contact that provides all the different indications remotely for ComPact NSX, ComPact NS, PowerPact Multistandard and EasyPact CVS circuit breakers.

Remote status information are ON/OFF (OF), trip indication (SD) and fault-trip indication (SDE) for all circuit breakers types.

The remote status information for trip indication due to an earth fault (SDV) is used for ComPact NSX and PowerPact Multistandard.

The contacts are installed in the device in dedicated slots.

This auxiliary contact is a common point changeover type contact with 1 normally open contact and 1 normally closed contact.

The rated current is 6A and the minimum load is 100mA at 24 VDC for utilization categories are AC12/AC15/DC12/DC14.

Screwless connections with spring terminals provide a fast and reliable connection.

The section of connected cables is between 0.5 mm² (AWG20) and 1.5 mm² (AWG16).

It complies with IEC 60947-5-1 standard.

More Information
More Information
Attribute Value
SKU 29450
range of product ComPact NSX100...250, ComPact NSX400...630, ComPact NSX100...250 DC, ComPact NSX100...250 DC PV, ComPact NSX400...630 DC, ComPact NSX400...630 DC PV, ComPact NS630b...1600, ComPact NS1600b...3200
product or component type MCCB
mounting mode clip-on
device short name OF, SD, SDE, SDV
range Aksesoris
[Ie] rated operational current AC-12: 6 A at 24 V AC 50/60 Hz, AC-12: 6 A at 48 V AC 50/60 Hz, AC-12: 6 A at 110 V AC 50/60 Hz, AC-12: 6 A at 220/240 V AC 50/60 Hz, AC-12: 6 A at 380/440 V AC 50/60 Hz, AC-12: 6 A at 480 V AC 50/60 Hz, AC-12: 6 A at 660/690 V AC 50/60 Hz, AC-15: 6 A at 24 V AC 50/60 Hz, AC-15: 6 A at 48 V AC 50/60 Hz, AC-15: 5 A at 110 V AC 50/60 Hz, AC-15: 4 A at 220/240 V AC 50/60 Hz, AC-15: 2 A at 380/440 V AC 50/60 Hz, AC-15: 1.5 A at 480 V AC 50/60 Hz, AC-15: 0.1 A at 660/690 V AC 50/60 Hz, DC-12: 6 A at 24 V DC, DC-12: 2.5 A at 48 V DC, DC-12: 0.6 A at 110 V DC, DC-12: 0.3 A at 250 V DC, DC-14: 1 A at 24 V DC, DC-14: 0.2 A at 48 V DC, DC-14: 0.05 A at 110 V DC, DC-14: 0.03 A at 250 V DC
range compatibility ComPact NSX, EasyPact CVS, PowerPact Multistandard, ComPact NSX DC, ComPact NS630b...1600, ComPact NS1600b...3200, Compact INS, Compact INV
accessory / separate part category spare part for Compact NS630b...1600, spare part for Compact NS1600b...3200
[Ith] conventional free air thermal current 5 A
auxiliary contacts type standard
auxiliary connection terminal spring 0.5-1.5 mm² (AWG 20...AWG 16)
fault type general electric fault
device application breaker status monitoring
local signalling ON/OFF indication for open/close, trip indicator for relay trip indicator, fault trip for electrical fault
minimum load 100 mA at 24 V DC
signal contacts composition 1 NO/NC