Schneider Electric

Compact NSX <630 circuit breaker NSX100F, 36 kA at 415 VAC, Micrologic 4.2 Vigi trip unit 40 A, 4 poles 4d - LV433834

Out of stock
SKU
LV433834
55%
Special Price Rp 8.737.754 Regular Price Rp 19.417.230
Details

This Compact NSX100F is a complete 4P 4d fixed circuit breaker designed to optimize space and breaking capacity.

It is an optimal choice for all standard and specific applications.

The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz.

The operational voltage is 440VAC 50/60Hz.

This product embeds a 40A rating electronic Micrologic 4.2 Vigi trip unit, with an integrated adjustable earth-leakage protection.

Micrologic 4.2 Vigi provides also adjustable long time and short time protections, and a fixed instantaneous protection.

This 4 poles version (140mm x 161mm x 86mm) comes with a variety of optional functions and accessories.

It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications.

Compact NSX100F is part of Schneider Electric EcoStruxure Power architecture.

More Information
More Information
Attribute Value
SKU LV433834
product certifications EAC, CCC, Marine
relative humidity 0-95 %
ambient air temperature for storage -40-85 °C
overvoltage category class II
pollution degree 3 conforming to IEC 60664-1
ambient air temperature for operation -25-70 °C
upside connection front
electrical shock protection class class II
range of product ComPact NSX100...250
product or component type MCCB
net weight 2.4 kg
mounting mode fixed
standards EN/IEC 60947
earth-leakage protection integrated
mechanical durability 50000 cycles
device short name VigiCompact NSX100F
breaking capacity 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
trip unit technology electronic
range ComPact NSX
IK degree of protection IK07 conforming to IEC 62262
[Ics] rated service breaking capacity 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
trip unit name Micrologic 4.2
trip unit rating 40-40 A at 40 °C
breaking capacity code F 36 kA 415 V AC
downside connection front
[Uimp] rated impulse withstand voltage 8 kV
product name ComPact NSX
earth-leakage protection class class A
short-time delay adjustment type fixed
thermal memory 20 minutes before and after tripping
operating mode OFF using the IΔn rotary switch
[Δt] residual earth-leakage time delay adjustment 0-0 ms, 60-60 ms, 150-150 ms, 500-500 ms, 1-1 s
network frequency 50/60 Hz
height 161 mm
mounting support backplate
compatibility code NSX100
width 140 mm
depth 86 mm
operating altitude 0...2000 m without derating, 2000 m...5000 m with derating
IP degree of protection IP40 conforming to IEC 60529
[In] rated current 40 A at 40 °C
network type AC
poles description 4P
electrical durability 30000 cycles at 440 V In, 50000 cycles at 440 V In/2
device application distribution
control type toggle
[Ue] rated operational voltage 440 V AC 50/60 Hz
local signalling flashing LED (green) for ready to operate, LED 105 % Ir (red) for overload, LED 90 % Ir (orange) for overload
protection type L : for overload protection (long time), So : for short time short-circuit protection with fixed delay, I : for instantaneous short-circuit protection, R : for earth-leakage protection
utilisation category category A
neutral protection setting 0.5 x Ir (3t + N/2), 1 x Ir (4t), no protection (3t)
connection pitch 35 mm
[Ui] rated insulation voltage 500 V AC 50/60 Hz
suitability for isolation yes conforming to EN/IEC 60947-2
protected poles description 3t, 4t, 3t + N/2
neutral position left
long time pick-up adjustment range 18...40 A
long time pick-up adjustment type Ir adjustable 9 settings
instantaneous pick-up adjustment range 600 A
long time delay adjustment type fixed
instantaneous pick-up adjustment type Ii fixed
number of slots 5 slot(s)
[Isd] short-time pick-up adjustment range 1.5...10 x Ir
[tr] long-time delay adjustment range 16-16 s at 6 x Ir, 11-11 s at 7.2 x Ir, 400-400 s at 1.5 x Ir
trip unit protection functions LSoIR
short-time pick-up adjustment type Isd adjustable
residual earth-leakage sensitity adjustment type adjustable
[tsd] short-time delay adjustment range 0.02-0.02 s
[IΔn] residual earth-leakage sensitive adjustment 300-300 mA, 500-500 mA, 1-1 A, 3-3 A, 5-5 A, 30-30 mA, 100-100 mA
residual earth-leakage time delay adjustment type adjustable
PT. Telesindo Citra Sejahtera © 2025 All Rights Reserved.