Schneider Electric
Compact NSX <630 circuit breaker NSX100F - TMD - 16 A - 3 poles 3d - LV429637
Out of stock
SKU
LV429637
Details
This Compact NSX100F is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity.
It is an optimal choice for all standard and specific applications.
The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz.
The operational voltage is 690VAC 50/60Hz.
This product embeds a 16A rating thermal-magnetic trip unit (TMD).
TMD trip unit provides an adjustable thermal overload protection and a fixed magnetic protection.
This 3 poles version (105mm x 161mm x 86mm) comes with a variety of optional functions and accessories.
It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications.
Compact NSX100F is part of Schneider Electric EcoStruxure Power architecture.
More Information
Attribute | Value |
---|---|
SKU | LV429637 |
product certifications | EAC, CCC, Marine |
relative humidity | 0-95 % |
ambient air temperature for storage | -50-85 °C |
overvoltage category | class II |
pollution degree | 3 conforming to IEC 60664-1 |
ambient air temperature for operation | -25-70 °C |
upside connection | front |
electrical shock protection class | class II |
range of product | ComPact NSX100...250 |
product or component type | MCCB |
net weight | 2.05 kg |
mounting mode | fixed |
standards | EN/IEC 60947 |
earth-leakage protection | without |
mechanical durability | 50000 cycles |
device short name | NSX100F |
breaking capacity | 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2, 85 kA at 240 V AC 50/60 Hz conforming to UL 508, 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2, 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 10 kA at 600 V AC 50/60 Hz conforming to UL 508, 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 25 kA at 480 V AC 50/60 Hz conforming to UL 508, 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
trip unit technology | thermal-magnetic |
range | ComPact NSX |
IK degree of protection | IK07 conforming to IEC 62262 |
[Ics] rated service breaking capacity | 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2, 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2, 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2, 12.5 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
trip unit name | TM-D |
trip unit rating | 16-16 A at 40 °C |
breaking capacity code | F 36 kA 415 V AC |
downside connection | front |
[Uimp] rated impulse withstand voltage | 8 kV |
product name | ComPact NSX |
short-time delay adjustment type | fixed |
network frequency | 50/60 Hz |
height | 161 mm |
mounting support | backplate |
compatibility code | NSX100 |
width | 105 mm |
depth | 86 mm |
operating altitude | 0...2000 m without derating, 2000 m...5000 m with derating |
IP degree of protection | IP40 conforming to IEC 60529 |
[In] rated current | 16 A at 40 °C |
network type | AC |
poles description | 3P |
electrical durability | 10000 cycles at 690 V In, 20000 cycles at 690 V In/2, 30000 cycles at 440 V In, 50000 cycles at 440 V In/2 |
device application | distribution |
control type | toggle |
[Ue] rated operational voltage | 690 V AC 50/60 Hz |
protection type | L : for overload protection (thermal), I : for short-circuit protection (magnetic) |
utilisation category | category A |
connection pitch | 35 mm |
[Ui] rated insulation voltage | 800 V AC 50/60 Hz |
suitability for isolation | yes conforming to EN/IEC 60947-2 |
protected poles description | 3t |
long time pick-up adjustment range | 0.7...1 x In |
long time pick-up adjustment type Ir | adjustable |
long time delay adjustment type | fixed |
number of slots | 5 slot(s) |
[Isd] short-time pick-up adjustment range | 190 A |
[tr] long-time delay adjustment range | 120-400 s at 1.5 x In, 15-15 s at 6 x Ir |
trip unit protection functions | LI |
short-time pick-up adjustment type Isd | fixed |
Technical Documents