Schneider Electric

Compact NSX <630 circuit breaker NSX630H - Micrologic 2.3 - 630 A - 4 poles 4d - LV432896

Out of stock
SKU
LV432896
55%
Special Price Rp 13.151.336 Regular Price Rp 29.225.190
Details

This Compact NSX630H is a complete 4P 4d fixed circuit breaker designed to optimize space and breaking capacity.

It is an optimal choice for all standard and specific applications.

The breaking capacity (Icu) is 70kA rms at 415VAC 50/60Hz.

The operational voltage is 690VAC 50/60Hz.

This product embeds an electronic Micrologic 2.3 trip unit, with 630A rating.

Micrologic 2.3 trip unit provides adjustable long time and short time protections, and a fixed instantaneous protection.

This 4 poles version (185mm x 255mm x 110mm) comes with a variety of optional functions and accessories.

It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications.

Compact NSX630H is part of Schneider Electric EcoStruxure Power architecture.

More Information
More Information
Attribute Value
SKU LV432896
product certifications EAC, CCC, Marine
relative humidity 0-95 %
ambient air temperature for storage -50-85 °C
overvoltage category class II
pollution degree 3 conforming to IEC 60664-1
ambient air temperature for operation -25-70 °C
upside connection front
electrical shock protection class class II
range of product ComPact NSX400...630
product or component type MCCB
net weight 8.13 kg
mounting mode fixed
standards EN/IEC 60947
earth-leakage protection without
mechanical durability 15000 cycles
device short name NSX630H
breaking capacity 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2, 85 kA at 240 V AC 50/60 Hz conforming to UL 508, 20 kA at 600 V AC 50/60 Hz conforming to UL 508, 65 kA at 480 V AC 50/60 Hz conforming to UL 508, 100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2, 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, 20 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
trip unit technology electronic
range ComPact NSX
IK degree of protection IK07 conforming to IEC 62262
[Ics] rated service breaking capacity 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2, 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2, 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2, 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
trip unit name Micrologic 2.3
trip unit rating 630-630 A at 40 °C
breaking capacity code H 70 kA 415 V AC
downside connection front
[Uimp] rated impulse withstand voltage 8 kV
product name ComPact NSX
short-time delay adjustment type fixed
thermal memory 20 minutes before and after tripping
network frequency 50/60 Hz
height 255 mm
mounting support backplate
compatibility code NSX630
width 185 mm
depth 110 mm
operating altitude 0...2000 m without derating, 2000 m...5000 m with derating
IP degree of protection IP40 conforming to IEC 60529
[In] rated current 630 A at 40 °C
network type AC
poles description 4P
electrical durability 6000 cycles at 690 V In/2, 4000 cycles at 440 V In, 8000 cycles at 440 V In/2, 2000 cycles at 690 V In
device application distribution
control type toggle
[Ue] rated operational voltage 690 V AC 50/60 Hz
local signalling flashing LED (green) for ready to operate, LED 105 % Ir (red) for overload, LED 90 % Ir (orange) for overload
protection type L : for overload protection (long time), So : for short time short-circuit protection with fixed delay, I : for instantaneous short-circuit protection
utilisation category category A
neutral protection setting 0.5 x Ir (3t + N/2), 1 x Ir (4t), no protection (3t)
connection pitch 45 mm
[Ui] rated insulation voltage 800 V AC 50/60 Hz
suitability for isolation yes conforming to EN/IEC 60947-2
protected poles description 3t, 4t, 3t + N/2
neutral position left
long time pick-up adjustment range 250...630 A
long time pick-up adjustment type Ir adjustable 9 settings
instantaneous pick-up adjustment range 6900 A
long time delay adjustment type fixed
instantaneous pick-up adjustment type Ii fixed
number of slots 6 slot(s)
[Isd] short-time pick-up adjustment range 1.5...10 x Ir
[tr] long-time delay adjustment range 16-16 s at 6 x Ir
trip unit protection functions LSoI
short-time pick-up adjustment type Isd adjustable 9 settings