Attribute Value
SKU REL52025
relative humidity 0-95 %, without condensation
ambient air temperature for storage -40-70 °C
ambient air temperature for operation -40-65 °C
environmental characteristic exposure to dry heat Bb tests conforming to EN/IEC 60068-2-2, exposure to cold Ad tests conforming to EN/IEC 60068-2-1, exposure to damp heat in service Db tests conforming to EN/IEC 60068-2-30, exposure to damp heat in service Cab tests conforming to EN/IEC 60068-2-78
range of product Easergy P3
product or component type Relay Proteksi Digital
net weight 2.5 kg maximum
standards IEC
device short name P3U30-5BAA2BCAA
range Easergy P3
mechanical robustness shocks: Ea conforming to IEC 60068-2-27, bumps (level: class II) conforming to IEC 60255-21-2, vibrations (level: class II) conforming to IEC 60255-21-1, seismic tests method A (level: class II) conforming to IEC 60255-21-3, vibrations: Fc conforming to IEC 60068-2-6, shocks (level: class II) conforming to IEC 60255-21-2, bumps: Ea conforming to IEC 60068-2-27
[Us] rated supply voltage 48...230 V AC/DC
electromagnetic compatibility emission tests class A conforming to CISPR 11, emission tests class A conforming to CISPR 22, EMC immunity conforming to EN/IEC 61000-4-18, EMC immunity conforming to EN/IEC 61000-4-11, emission tests conforming to IEC/EN 60255-26 ed. 3, EMC immunity conforming to IEC/EN 60255-26 ed. 3, EMC immunity level 4 conforming to EN/IEC 61000-4-2, EMC immunity level 3 conforming to EN/IEC 61000-4-5, EMC immunity conforming to EN/IEC 61000-4-8, EMC immunity level 5 conforming to EN/IEC 61000-4-9, EMC immunity conforming to EN/IEC 61000-4-29, EMC immunity level 3 conforming to EN/IEC 61000-4-3, EMC immunity level 4 conforming to EN/IEC 61000-4-4, EMC immunity level 3 conforming to EN/IEC 61000-4-6, EMC immunity conforming to EN/IEC 61000-4-17
type of measurement frequency, power factor, apparent power, active energy, active power, reactive power, tan φ, cos φ, current 3-phase, current zero sequence, current positive sequence, current negative sequence, current ratio of negative and positive, voltage phase to earth, voltage phase to phase, voltage zero sequence, voltage positive sequence, voltage negative sequence, voltage ratio of negative and positive, short circuit fault reactance, fault location current, earth fault reactance, RMS active power, RMS reactive power, RMS apparent power, reactive energy, power angle, voltage phasor diagram view, current phasor diagram view, current 2nd, 15th harmonics with THD, voltage 2nd, 15th harmonics with THD, voltage interruption, condition monitoring CB wear
relay application universal
analogue output number 0
network and machine diagnosis type event recording, disturbance recording, tripping context
number of key 2 customizable
redundancy communication port protocol RSTP, PRP
operating threshold 110...230 V AC/DC
time synchronisation protocol SNTP
switchgear diagnosis type CT/VT supervision ANSI code: 60, CT supervision, trip circuit supervision ANSI code: TCS
software name EcoStruxure Power Device, eSetup Easergy Pro
single line diagram 4 controlled + 8 displayed
connections - terminals screw removable (digital input/output), pin removable (current transformer), pin removable (voltage transformer)
height 169.5 mm
width 170 mm
depth 205 mm
operating altitude 2000 m
IP degree of protection IP54 conforming to IEC 60529
control type switchgear control and monitoring, programmable switchgear interlocking, local control on single-line diagram, local control with I/O keys, local/remote control, 2 function keys, mobile application with Easergy SmartApp, web-server, programmable logic
local signalling 4 LEDs, 8 LEDs programmable
integrated connection type USB port 1 front, RJ45 2 rear
protection type phase overcurrent 50/51, directional phase overcurrent 67, earth fault overcurrent 50N/51N, directional earth fault 67N, transient earth fault 67NI, capacitor bank unbalance 51C, broken conductor 46 I2/I1, cold load pick-up, switch ON to fault (SOTF), breaker failure 50BF, directional active underpower 37P, fault locator 21FL, recloser 79, phase undercurrent 37, excessive starting time, locked rotor 48/51LR, motor restart inhibition 66, capacitor overvoltage 59C, negative sequence overcurrent 46, overvoltage 59, undervoltage 27, positive sequence undervoltage 27P, earth fault overvoltage 59N, underfrequency 81/81N, rate of change of frequency 81R, synchro-check 25, lockout relay 86, CT supervision 60, VT supervision 60, H2 detection 68H2, H5 detection, H5 detection 68H5, programmable stages 99, programmable curve
protective treatment conformal coating
number of outputs 1 watchdog, 8
communication port protocol Ethernet/IP, Modbus TCP, IEC 61850 ed. 1, IEC 61850 ed. 2, IEC 60870-5-101, DNP3 TCP
cybersecurity password protection, port hardening
analogue input number 0
setting 4
input type : 1/5 A CT phase current 3, : 1/5 A CT residual current 1, : 100 V/110 V VT voltage 4
web server embedded HTTP server
monitoring function trip circuit supervision 74, circuit breaker monitoring, relay self-monitoring
digital input number 16
number of sensors 0 arc sensor(s), 0 temperature sensor(s)
arc flash protection no