Schneider Electric

EasyPact CVS - CVS630N ETS 2.3 circuit breaker - 630 A - 4P/4d - LV563511

Out of stock
SKU
LV563511
50%
Special Price Rp 11.542.335 Regular Price Rp 23.084.670
Details

EasyPact CVS630N is a 3 poles 3d fixed circuit breaker with a high level of performance and cost-saving functionality.

It is an optimal choice for small and medium-sized buildings protection applications.

The breaking capacity (Icu) is 50kA rms at 415VAC 50/60Hz.

The operational voltage is 440VAC 50/60Hz.

This product embeds an electronic ETS 2.3 trip unit, with 630A rating.

ETS 2.3 trip unit provides adjustable long time and short time protections, and a fixed instantaneous protection.

This 4 poles version (185mm x 255mm x 110mm) comes with a variety of optional functions and accessories.

EasyPact CVS630N is compliant with international standards (IEC 60947, CCC, EAC).

It can be installed in class II insulation switchboards as it is a class II front face device (IEC 60664-1).

More Information
More Information
Attribute Value
SKU LV563511
product certifications IEC, GOST
ambient air temperature for storage -50-85 °C
pollution degree 3 conforming to IEC 60664-1
ambient air temperature for operation -25-70 °C
upside connection front
electrical shock protection class class II
range of product Easypact CVS400...630
product or component type MCCB
net weight 7.1 kg
mounting mode fixed
standards IEC 60947-2, EN 60947-2
earth-leakage protection without
mechanical durability 15000 cycles
device short name CVS630N
breaking capacity 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, 42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
trip unit technology electronic
range EasyPact CVS
[Ics] rated service breaking capacity 70 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, 32 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
trip unit name ETS 2.3
trip unit rating 630-630 A at 40 °C
breaking capacity code N
downside connection front
[Uimp] rated impulse withstand voltage 8 kV conforming to EN/IEC 60947-2
product name EasyPact CVS
short-time delay adjustment type fixed
thermal memory yes
network frequency 50/60 Hz
connections - terminals screw connection
height 255 mm
mounting support backplate
compatibility code CVS630
width 185 mm
depth 110 mm
IP degree of protection IP40
[In] rated current 630 A at 40 °C
network type AC
poles description 4P
electrical durability 4000 cycles 415 V In conforming to IEC 60947-2
device application distribution
control type toggle
protection type short time short-circuit protection, instantaneous short-circuit protection, overload protection (long time)
utilisation category category A
neutral protection setting 1 x Ir (4d), 0.5 x Ir (3d + N/2)
connection pitch 45 mm
protected poles description 3d, 3d + N/2, 4d
neutral position left
long time pick-up adjustment range 250...630 A
long time pick-up adjustment type Ir adjustable 9 settings
contact position indicator yes
instantaneous pick-up adjustment range 11 x In
long time delay adjustment type fixed
instantaneous pick-up adjustment type Ii fixed
[Isd] short-time pick-up adjustment range 1.5...10 x Ir
[tr] long-time delay adjustment range 5.5-5.5 s at 7.2 x Ir, 8-8 s at 6 x Ir, 200-200 s at 1.5 x Ir
trip unit protection functions LSoI
short-time pick-up adjustment type Isd adjustable 9 settings