This is a 50A circuit breaker for EasyPact EZC100N.

This product can work below rated operational voltage(Ue) 415VAC at 50/60Hz or 125VDC network.

The ultimate breaking capacity(Icu) is shown differently, depended on the condition of network, Ics=50%Icu if need to match.

This version of product is designed one pole frame with detection on one pole,equiped TMD trip unit for thermal-magnetic protection.

It is compliance with standard IEC60947, CE certification and some independent lab(KEMA,ASEFA,TUV) or third-party Tilva.

This device is certified for operation in pollution degree III environment as defined by IEC60947, and pass the test of extremely atmospheric conditions.

Device can be mounted vertically or horizontally in a metal enclosure,and against from safety risk by padlocking.

The degree of protection is IP40 for direct rotary handle,and IP54 for extended rotary handle.

This series have slots used for indication or voltage release auxiliaries positioning , depending on where it is inserted in the device behind the front cover of circuit breaker.

The fixed dimension is 25mm(width),130mm(height),60mm(Depth).

More Information
More Information
Attribute Value
SKU EZC100N1050
range EasyPact EZC
product or component type MCCB
[In] rated current 100 A at 40 °C
trip unit technology thermal-magnetic
breaking capacity 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2, 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2, 18 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2, 2.5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2, 2.5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
ambient air temperature for operation -25-70 °C
ambient air temperature for storage -35-85 °C
control type toggle
mounting mode fixed
mechanical durability 8500 cycles
IK degree of protection IK07 conforming to IEC 62262
network frequency 50/60 Hz
trip unit rating 50-50 A at 50 °C
earth-leakage protection without
breaking capacity code N
downside connection front
upside connection front
[Ue] rated operational voltage 125 V DC conforming to IEC 60947-2, 415 V AC 50/60 Hz conforming to IEC 60947-2
product name EasyPact EZC
poles description 1P
protection type short-circuit protection, overload protection
standards JIS C8201-2-2, EN/IEC 60947-2, EN/IEC 60947-1, GB/T 14048.2
device application distribution
[Ics] rated service breaking capacity 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2, 2.5 kA at 125 V DC conforming to IEC 60947-2, 9 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2, 1.25 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2, 1.25 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
electrical durability category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
connection pitch 25 mm
device short name Easypact EZC100N
network type AC, DC
pollution degree 3 conforming to IEC 60664-1, 3 conforming to IEC 947-1
protected poles description 1t
trip unit name TM-D
local signalling positive contact indication
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
height 130 mm
depth 60 mm
width 25 mm
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
compatibility code EZC100
IP degree of protection IP20 conforming to IEC 60529
utilisation category category A
suitability for isolation yes conforming to IEC 60947-2