| product or component type | MCCB | 
| [In] rated current | 100 A at 40 °C | 
| trip unit technology | thermal-magnetic | 
| breaking capacity | 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2, 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2, 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2, 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2, 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2, 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 15 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2, 18 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 | 
| ambient air temperature for operation | -25-70 °C | 
| ambient air temperature for storage | -35-85 °C | 
| control type | toggle | 
| mounting mode | fixed | 
| mechanical durability | 8500 cycles | 
| IK degree of protection | IK07 conforming to EN 50102 | 
| network frequency | 50/60 Hz | 
| trip unit rating | 60-60 A at 50 °C | 
| earth-leakage protection | without | 
| breaking capacity code | N | 
| downside connection | front | 
| upside connection | front | 
| [Ue] rated operational voltage | 550 V AC 50/60 Hz conforming to IEC 60947-2, 250 V DC conforming to IEC 60947-2 | 
| product name | EasyPact EZC | 
| poles description | 4P | 
| protection type | short-circuit protection, overload protection | 
| standards | JIS C8201-2-2, EN/IEC 60947-2, EN/IEC 60947-1, GB/T 14048.2 | 
| device application | distribution | 
| [Ics] rated service breaking capacity | 2.5 kA at 125 V DC conforming to IEC 60947-2, 2.5 kA at 250 V DC conforming to IEC 60947-2, 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2, 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2, 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2, 12.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2, 12.5 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2, 9 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 | 
| electrical durability | category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 | 
| connection pitch | 25 mm | 
| device short name | Easypact EZC100N | 
| network type | AC, DC | 
| pollution degree | 3 conforming to IEC 60947 | 
| protected poles description | 3t | 
| trip unit name | TM-D | 
| local signalling | positive contact indication | 
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 
| height | 130 mm | 
| depth | 60 mm | 
| width | 100 mm | 
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 | 
| compatibility code | EZC100 | 
| IP degree of protection | IP20 conforming to IEC 60529 | 
| utilisation category | category A | 
| suitability for isolation | yes conforming to IEC 60947-2 | 