Schneider Electric
EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 32A - 220 V AC coil - LC1E3210M7
Out of stock
SKU
LC1E3210M7
Details
EasyPact TVS contactor 3 poles for motor applications up to 32A 15kW@440V.
It provides a 220V 50/60Hz AC coil, 1NO built-in auxiliary contacts, power and control connections by screw clamp terminals.
56mm width for standard operating rates up to 1800 cycles per hour.
It procures standard reliability and durability with 1 Mcycles electrical durability AC-3 and 8 Mcycles mechanical durability.
It can cover -5°C to 55°C working temperature and mounted by DIN-rail, No derating up to 3000m altitude.
Multi-standards certified (IEC, CCC, EAC) and Green Premium compliant (RoHs/Reach).
More Information
Attribute | Value |
---|---|
SKU | LC1E3210M7 |
product certifications | EAC |
ambient air temperature for storage | -60-80 °C |
overvoltage category | III |
pollution degree | 3 |
ambient air temperature for operation | -5-55 °C |
non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact, 1.5 ms on de-energisation guaranteed between NC and NO contact |
[Icw] rated short-time withstand current | 260 A 40 °C - 10 s for power circuit, 138 A 40 °C - 60 s for power circuit, 60 A 40 °C - 600 s for power circuit |
product or component type | Kontaktor |
net weight | 0.45 kg |
standards | IEC 60947-4-1, IEC 60947-5-1, IEC 60947-1 |
mechanical durability | 8000000 cycles |
device short name | LC1E |
range | EasyPact TVS |
average impedance | 2.5 mOhm - Ith 50 A 50 Hz for power circuit |
[Ie] rated operational current | 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
[Uc] control circuit voltage | 220 V AC 50/60 Hz |
[Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 |
product name | EasyPact TVS |
minimum switching current | 5 mA for control circuit |
mechanical robustness | vibrations contactor open: 1.5 Gn, 5...300 Hz, vibrations contactor closed: 3 Gn, 5...300 Hz, shocks contactor closed: 10 Gn for 11 ms, shocks contactor open: 6 Gn for 11 ms |
power dissipation per pole | 5 W AC-1, 2 W AC-3 |
control circuit type | AC at 50/60 Hz |
contactor application | motor control, resistive load |
insulation resistance | > 10 MOhm for control circuit |
rated breaking capacity | 256 A at 440 V for power circuit conforming to IEC 60947 |
Irms rated making capacity | 320 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
pole contact composition | 3 NO |
operating time | 12...22 ms on closing, 4...19 ms on opening |
hold-in power consumption in VA | 8.5-8.5 VA 50 Hz cos phi 0.3 (at 20 °C), 8.5-8.5 VA 60 Hz cos phi 0.3 (at 20 °C) |
inrush power in VA | 95-95 VA 50 Hz cos phi 0.75 (at 20 °C), 95-95 VA 60 Hz cos phi 0.75 (at 20 °C) |
permissible ambient air temperature around the device | -20-70 °C at Uc |
connections - terminals | control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 1.5-6 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 2 1.5-6 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 1-6 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible with cable end |
height | 84 mm |
mounting support | DIN rail, plate |
width | 56 mm |
depth | 86 mm |
operating altitude | 3000 m without derating |
IP degree of protection | IP2x conforming to IEC 60529 |
poles description | 3P |
colour | grey (RAL 7011) |
tightening torque | control circuit: 1.2 N.m, control circuit: 1.4 N.m, power circuit: 2.1 N.m, power circuit: 2.3 N.m |
electrical durability | 350000 cycles AC-1, 1000000 cycles AC-3 |
[Ue] rated operational voltage | power circuit: <= 690 V AC 50/60 Hz |
utilisation category | AC-3, AC-1 |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
auxiliary contact composition | 1 NO |
control circuit voltage limits | operational: 0.85...1.1 Uc at 50/60 Hz (at <55 °C), drop-out: 0.3...0.6 Uc at 50/60 Hz (at <55 °C) |
associated fuse rating | 63 A gG at <= 690 V coordination type 1 for power circuit, 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 |
minimum switching voltage | 17 V for control circuit |
maximum operating rate | 1800 cyc/h 60 °C |
protective treatment | TH (pollution degree 3) conforming to IEC 60068 |
fire resistance | 850 °C conforming to IEC 60695-2-1 |
motor power kW | 7.5 kW at 220...230 V AC 50/60 Hz, 15 kW at 380...400 V, 15 kW at 415 V, 15 kW at 440 V, 18.5 kW at 500 V, 18.5 kW at 660...690 V |
heat dissipation | 2-3 W for control circuit |