Schneider Electric

EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 80A - 220 V AC coil - LC1E80M7

Out of stock
SKU
LC1E80M7
38%
Special Price Rp 1.514.040 Regular Price Rp 2.442.000
Details

EasyPact TVS contactor 3 poles for motor applications up to 80A 45kW@440V.

It provides a 220V 50/60Hz AC coil, without built-in auxiliary contacts, power and control connections by screw clamp terminals.

85mm width for standard operating rates up to 1200 cycles per hour.

It procures standard reliability and durability with 0.9 Mcycles electrical durability AC-3 and 3 Mcycles mechanical durability.

It can cover -5°C to 55°C working temperature and mounted by DIN-rail, No derating up to 3000m altitude.

Multi-standards certified (IEC, CCC, EAC) and Green Premium compliant (RoHs/Reach).

More Information
More Information
Attribute Value
SKU LC1E80M7
product certifications EAC
ambient air temperature for storage -60-80 °C
overvoltage category III
pollution degree 3
ambient air temperature for operation -5-55 °C
non-overlap time 1.5 ms on energisation guaranteed between NC and NO contact, 1.5 ms on de-energisation guaranteed between NC and NO contact
[Icw] rated short-time withstand current 640 A 40 °C - 10 s for power circuit, 320 A 40 °C - 60 s for power circuit, 135 A 40 °C - 600 s for power circuit
product or component type Kontaktor
net weight 1.52 kg
standards IEC 60947-4-1, IEC 60947-5-1, IEC 60947-1
mechanical durability 300000 cycles
device short name LC1E
range EasyPact TVS
average impedance 0.8 mOhm - Ith 110 A 50 Hz for power circuit
[Ie] rated operational current 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 110 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage 220 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 6 kV coil not connected to the power circuit conforming to IEC 60947
product name EasyPact TVS
minimum switching current 5 mA for control circuit
mechanical robustness vibrations contactor open: 1.5 Gn, 5...300 Hz, vibrations contactor closed: 3 Gn, 5...300 Hz, shocks contactor open: 6 Gn for 11 ms, shocks contactor closed: 7 Gn for 11 ms
power dissipation per pole 5.1 W AC-3, 9.7 W AC-1
control circuit type AC at 50/60 Hz
contactor application motor control, resistive load
insulation resistance > 10 MOhm for control circuit
rated breaking capacity 640 A at 440 V for power circuit conforming to IEC 60947
Irms rated making capacity 800 A at 440 V AC for power circuit conforming to IEC 60947-4-1
pole contact composition 3 NO
operating time 20...35 ms on closing, 6...30 ms on opening
hold-in power consumption in VA 22-22 VA 60 Hz cos phi 0.3 (at 20 °C), 20-20 VA 50 Hz cos phi 0.3 (at 20 °C)
inrush power in VA 200-200 VA 50 Hz cos phi 0.75 (at 20 °C), 220-220 VA 60 Hz cos phi 0.75 (at 20 °C)
permissible ambient air temperature around the device -20-70 °C at Uc
connections - terminals control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 4-50 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 4-16 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 4-50 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 2 4-50 mm² - cable stiffness: solid without cable end
height 127 mm
mounting support DIN rail, plate
width 85 mm
depth 121 mm
operating altitude 3000 m without derating
IP degree of protection IP2x conforming to IEC 60529
poles description 3P
colour grey (RAL 7011)
tightening torque control circuit: 1.2 N.m, control circuit: 1.4 N.m, power circuit: 12 N.m, power circuit: 13.5 N.m
electrical durability 350000 cycles AC-1, 900000 cycles AC-3
[Ue] rated operational voltage power circuit: <= 690 V AC 50/60 Hz
utilisation category AC-3, AC-1
[Ui] rated insulation voltage 690 V conforming to IEC 60947-4-1
auxiliary contact composition 1 NO + 1 NC
control circuit voltage limits operational: 0.85...1.1 Uc at 50/60 Hz (at <55 °C), drop-out: 0.3...0.6 Uc at 50/60 Hz (at <55 °C)
associated fuse rating 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1, 160 A gG at <= 690 V coordination type 1 for power circuit
minimum switching voltage 17 V for control circuit
maximum operating rate 1200 cyc/h 60 °C
protective treatment TH (pollution degree 3) conforming to IEC 60068
fire resistance 850 °C conforming to IEC 60695-2-1
motor power kW 22 kW at 220...230 V AC 50/60 Hz, 37 kW at 380...400 V, 45 kW at 415 V, 45 kW at 440 V, 45 kW at 500 V, 45 kW at 660...690 V
heat dissipation 6-10 W for control circuit
PT. Telesindo Citra Sejahtera © 2025 All Rights Reserved.