EasyPact TVS contactor 4 poles for category AC-1 applications up to 80A.
It provides a 220V 50/60Hz AC coil, 4NO built-in auxiliary contacts, power and control connections by screw clamp terminals.
84.5mm width for standard operating rates up to 1200 cycles per hour.
It procures standard reliability and durability with 0.35 Mcycles electrical durability and 5 Mcycles mechanical durability.
It can cover -5°C to 55°C working temperature and mounted by DIN-rail, No derating up to 3000m altitude.
Multi-standards certified (IEC, CCC, EAC) and Green Premium compliant (RoHs/Reach).
More Information
Attribute | Value |
---|---|
SKU | LC1E65004M7 |
ambient air temperature for storage | -60-80 °C |
overvoltage category | III |
pollution degree | 3 |
ambient air temperature for operation | -5-55 °C |
[Icw] rated short-time withstand current | 520 A 40 °C - 10 s for power circuit, 260 A 40 °C - 60 s, 110 A 40 °C - 600 s |
product or component type | Kontaktor |
net weight | 1.3 kg |
standards | IEC 60947-4-1, IEC 60947-5-1 |
mechanical durability | 5000000 cycles |
device short name | LC1E |
range | EasyPact TVS |
average impedance | 1 mOhm - Ith 80 A 50 Hz for power circuit |
[Ie] rated operational current | 80 A (at <60 °C) at <= 415 V AC AC-1 for power circuit |
[Uc] control circuit voltage | 220 V AC 50/60 Hz |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
product name | EasyPact TVS |
mechanical robustness | vibrations contactor open: 1.5 Gn, 5...300 Hz, vibrations contactor closed: 3 Gn, 5...300 Hz, shocks contactor open: 6 Gn for 11 ms, shocks contactor closed: 7 Gn for 11 ms |
power dissipation per pole | 4.2 W AC-3, 6.4 W AC-1 |
control circuit type | AC at 50/60 Hz |
contactor application | resistive load |
insulation resistance | > 10 MOhm for control circuit |
rated breaking capacity | 520 A at 440 V for power circuit conforming to IEC 60947 |
Irms rated making capacity | 650 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
pole contact composition | 4 NO |
operating time | 20...26 ms on closing, 8...12 ms on opening |
hold-in power consumption in VA | 13-13 VA 60 Hz cos phi 0.3 (at 20 °C), 15-15 VA 50 Hz cos phi 0.3 (at 20 °C) |
inrush power in VA | 140-140 VA 60 Hz cos phi 0.75 (at 20 °C), 160-160 VA 50 Hz cos phi 0.75 (at 20 °C) |
permissible ambient air temperature around the device | -20-70 °C at Uc |
connections - terminals | control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 2 2.5-16 mm² - cable stiffness: solid without cable end |
height | 127 mm |
mounting support | DIN rail, plate |
width | 85 mm |
depth | 125 mm |
operating altitude | 3000 m without derating |
IP degree of protection | IP2x conforming to IEC 60529 |
poles description | 4P |
colour | grey (RAL 7011) |
tightening torque | control circuit: 1.2 N.m, control circuit: 1.4 N.m, power circuit: 5 N.m, power circuit: 5.8 N.m |
electrical durability | 350000 cycles AC-1, 900000 cycles AC-3 |
[Ue] rated operational voltage | power circuit: <= 690 V AC 50/60 Hz |
utilisation category | AC-1 |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
control circuit voltage limits | operational: 0.85...1.1 Uc at 50/60 Hz (at <55 °C), drop-out: 0.3...0.6 Uc at 50/60 Hz (at <55 °C) |
associated fuse rating | 125 A gG at <= 690 V coordination type 1 for power circuit conforming to IEC 60947-5-1 |
maximum operating rate | 1200 cyc/h 60 °C |
protective treatment | TH (pollution degree 3) conforming to IEC 60068 |
fire resistance | 850 °C conforming to IEC 60695-2-1 |
heat dissipation | 6-10 W for control circuit |