Schneider Electric        
    
    
        
            
    
EasyPact TVS thermal overload relay 84...135 A - class 10A - LRE482
            Out of stock
        
    
            SKU
        
LRE482
                        Details
                    
                    
The LRE relay is a differential thermal overload relays for use with fuses or magnetic circuit-breakers GV2 L and GV3 L.
Its thermal setting range is 84-135A 50/60Hz and the tripping class is 10A conforming to IEC 60947-4-1.
It can be direct mounted on EasyPact TVS contactors with directly connected by connector.
It protects unbalanced loads and motors with 75 - 110kW at 400VAC.
It provides manual or automatic reset, trip auxiliary contact and flag indicator.
Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach).
                        More Information
                    
                        | Attribute | Value | 
|---|---|
| SKU | LRE482 | 
| product certifications | GOST | 
| ambient air temperature for storage | -60-80 °C | 
| ambient air temperature for operation | -20-60 °C without derating conforming to IEC 60947-4-1, -20-70 °C with derating | 
| product or component type | Relay Beban Lebih Termal | 
| net weight | 2.2 kg | 
| standards | IEC 60947-4-1, IEC 60947-5-1 | 
| device short name | LRE | 
| range | EasyPact TVS | 
| product compatibility | LC1E120...630 | 
| product name | EasyPact TVS | 
| mechanical robustness | shocks: 6 Gn for 11 ms conforming to IEC 60068-2-7, vibrations: 3 Gn conforming to IEC 60068-2-6 | 
| [Ith] conventional free air thermal current | 5 A for signalling circuit | 
| electromagnetic compatibility | surge withstand: 6 kV conforming to IEC 60801-5 | 
| signalling function | relay trip indicator | 
| relay application | motor protection | 
| tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 | 
| network frequency | 50...60 Hz | 
| connections - terminals | signalling circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, signalling circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible without cable end, signalling circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: solid without cable end, power circuit: lugs, power circuit: bars - busbar cross section: 3 x 18 mm | 
| height | 141 mm | 
| mounting support | plate, under contactor | 
| width | 180 mm | 
| depth | 134 mm | 
| dielectric strength | 6 kV at 50 Hz conforming to IEC 60255-5 | 
| IP degree of protection | IP00 conforming to IEC 60529 | 
| network type | AC | 
| tightening torque | signalling circuit: 1.7 N.m - on screw clamp terminals, power circuit: 27.5 N.m - on bars M8, power circuit: 27.5 N.m - on lugs M8 | 
| control type | push-button red stop:, push-button green reset: | 
| [Ue] rated operational voltage | <= 690 V AC | 
| local signalling | trip indicator | 
| connection pitch | 34.8 mm | 
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 | 
| auxiliary contact composition | 1 NO + 1 NC | 
| associated fuse rating | 5 A gG for signalling circuit, 200 A gG for power circuit, 160 A aM for power circuit | 
| protective treatment | TH conforming to IEC 60068 | 
| fire resistance | 850 °C conforming to IEC 60068-2-1 | 
| thermal protection adjustment range | 84-135 A | 
| phase failure sensitivity | tripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1 | 
| thermal overload class | class 10A conforming to IEC 60947-4-1 | 
| temperature compensation | -20-60 °C | 
                        Technical Documents
                    
                    
    
                