Schneider Electric

Masterpact MT remote controlled source changeover, Transferpact, ACP plate and BA controller, 380 VAC to 415 VAC 50/60Hz, 440 VAC 60Hz - 29471

Out of stock
SKU
29471
47%
Special Price Rp 22.031.215 Regular Price Rp 41.568.330
Details

It is a remote controlled source changeover system for Compact NSX, Compact NS and Masterpact devices.

It is composed of an ACP plate and of an integrated BA controller.

This ACP provides in a single unit the protection of the controller, the control and the connection to the devices.

The BA controller is used to create simple source-changeover system that switch from one source to another depending on the presence of voltage UN on the “Normal” source.

The BA controller is generally used to manage two permanent sources.

The control voltage is from 380VAC to 415VAC 50/60Hz, or 440VAC 60Hz.

More Information
More Information
Attribute Value
SKU 29471
range of product ComPact NS630b...1600, Masterpact NW, Masterpact NT, NSX400...630, NSX100...250, Compact NS100...630
product or component type Air Circuit Breaker
standards IEC 947-5-1
device short name ACP + BA
range Aksesoris
product compatibility Compact NSX400...630, Compact NSX100...250, Compact NS630b...1600
[Ie] rated operational current AC-12: 4 A AC 440 V, AC-13: 7 A AC 48 V, AC-14: 4 A AC 110 V, AC-14: 4 A AC 220/240 V, AC-14: 5 A AC 24 V, AC-14: 5 A AC 48 V, AC-15: 3 A AC 220/240 V, AC-15: 4 A AC 110 V, AC-15: 5 A AC 24 V, AC-15: 5 A AC 48 V, DC-12: 0.4 A DC 250 V, AC-12: 5 A AC 380/415 V, DC-12: 0.6 A DC 110 V, DC-12: 2 A DC 48 V, DC-12: 8 A DC 24 V, DC-13: 2 A 24 V, AC-12: 8 A AC 110 V, AC-12: 8 A AC 220/240 V, AC-12: 8 A AC 24 V, AC-12: 8 A AC 48 V, AC-13: 6 A AC 110 V, AC-13: 6 A AC 220/240 V, AC-13: 7 A AC 24 V
range compatibility ComPact NSX circuit breaker, ComPact NS circuit breaker, MasterPact NT circuit breaker, Masterpact NW circuit breaker
IK degree of protection front: IK07 conforming to EN 50102
accessory / separate part category interlocking accessory
[Ith] conventional free air thermal current 8 A
[Us] rated supply voltage 440 V AC at 60 Hz, 380...415 V AC at 50/60 Hz
output type contacts customer: indication of operation in automatic or stop mode
operating mode automatic operation, forced operation on replacement source, forced operation on normal source, stop (both normal and replacement source off)
selection modes circuit breaker on N, circuit breaker on R
test function by opening the P25M circuit breaker supplying the controller
compatibility code ACP+BA
IP degree of protection IP20 connectors: conforming to EN 60529, IP40 front: conforming to EN 60529, IP30 side: conforming to EN 60529
local signalling off, on, fault trip
interlocked device Masterpact NW, NSX400...630, NSX100...250, Masterpact NT, Compact NS630b...1600, Compact NS100...630
input type contacts customer voluntary order to transfer to source R
complementary function additional contact: transfer to replacement source only if contact is closed, voluntary transfer to replacement source (e.g. energy management commands)