Modicon TM3 Safety module - 3 Function, Cat 4 PL e/SIL CL3 (spring) 24Vdc - TM3SAK6RG
This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262.
The analogue output module provides 2 outputs with 11bit + sign and 12bit resolution.
It is an output module with a rated supply voltage of 24V DC and a current consumption of 70mA at 24V DC via external supply full load.
This product is capable of controlling variable speed drives or any device equipped with a current or voltage input.
There is an insulation between output and supply at 1500V AC, output and internal logic at 500V AC.
It is furnished with removable screw terminal for electrical connection with 5.08mm pitch adjustment for outputs.
It is an IP20 rated product.
Its dimensions are 23.6mm (Width) x 70mm (Depth) x 90mm (Height).
It weighs 0.115kg.
This product is certified by CE.
It meets EN/IEC 61131-2 and EN/IEC 61010-2-201 standards.
This module is compatible with Modicon M262, Modicon M241, Modicon M251 and Modicon M221 logic controller.
It supports top hat type TH35-15, top hat type TH35-7.5 rail conforming to IEC 60715 and plate or panel with fixing kit mount.
Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism.
A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers.
Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.
Attribute | Value |
---|---|
SKU | TM3SAK6RG |
product certifications | EAC, RCM, TÜV, UL 61010-2-201, CSA Haz Loc Class 1 Division 2 (pending), CSA 61010-2-201 (pending), ANSI Haz Loc Class 1 Division 2 (pending) |
relative humidity | 10-95 %, without condensation (in operation), 10-95 %, without condensation (in storage) |
ambient air temperature for storage | -25-70 °C |
pollution degree | 2 |
ambient air temperature for operation | -10-55 °C horizontal installation |
safety reliability data | DC = 95 % conforming to EN/ISO 13849-1, PFHd = 5E-9 1/h conforming to IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A, PFHd = 30E-9 1/h conforming to IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A, MTTFd = 500 years conforming to EN/ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A, MTTFd = 85 years conforming to EN/ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A, SFF = 95 % conforming to IEC 61508-1, HFT = 1 conforming to IEC 61508-1, type = A conforming to IEC 61508-1 |
resistance to electrostatic discharge | 8 kV in air conforming to EN/IEC 61000-4-2, 6 kV on contact conforming to EN/IEC 61000-4-2 |
minimum output current | 10 mA for relay output |
number of safety circuits | 3 NO for relay instantaneous opening |
output voltage | 10 V relay output |
range of product | Modicon TM3 Safety |
product or component type | Relay & Power Supply |
current consumption | 100 mA at 24 V DC external supply |
net weight | 0.19 kg |
standards | EN/IEC 60947-1, EN/IEC 60947-5-1, EN/ISO 13850, EN 60204-1, EN/IEC 61131-2:2007, EN 1088/ISO 14119, EN/ISO 13849-1:2008, EN/ISO 13849-2:2012, EN/IEC 62061:2005, EN/IEC 61508:2010, EN/IEC 60947-5-1:2010, EN/IEC 60204-1:2005, EN/IEC 60204-1:2009/A1, IEC 61010-1:2010, EN 50581:2012 |
device short name | TM3SAK |
breaking capacity | 360 VA holding AC-15 B300 relay output, 3600 VA inrush AC-15 B300 relay output, 4 A 24 V 50 ms DC-13 relay output |
range | Modicon TM3 |
product compatibility | safety light curtains conforming to EN/IEC 61496-1 (type 4), sensing mat/edges conforming to EN 1760-1 |
[Uc] control circuit voltage | 24 V DC |
[Uimp] rated impulse withstand voltage | 4 kV overvoltage category III conforming to IEC 60647-5-1 |
mechanical robustness | bumps 6 ms 300 shocks (25 gn) conforming to IEC 60068-2-27 |
[Ith] conventional free air thermal current | 18 A |
[Us] rated supply voltage | 24 V - 15...20 % DC |
electromagnetic compatibility | electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2, 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5, electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2, conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6, susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to EN/IEC 61000-4-3, susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3, susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3, magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to EN/IEC 61000-4-8, electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to EN/IEC 61000-4-4, electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to EN/IEC 61000-4-4, radiated emission - test level: 40 dBµV/m class A (24 V) conforming to EN 55011, radiated emission - test level: 47 dBµV/m class A (24 V) conforming to EN 55011 |
electrical connection | spring terminal |
maximum cable distance between devices | 30 m |
output type | relay instantaneous opening, 3 NO circuit(s), potential free |
function of module | emergency stop monitoring 1-channel wiring, emergency stop monitoring 2-channel wiring, monitoring of a movable guard with 2 switches and automatic start, monitoring of a movable guard, multiple emergency stop monitoring 2-channel wiring, proximity sensor monitoring PNP/PNP, proximity sensor monitoring PNP/NPN, sensing mat and edges monitoring, monitoring of electro-sensitive protection equipment (ESPE) PNP/PNP, monitoring of electro-sensitive protection equipment (ESPE) PNP/NPN |
maximum response time on input open | 40 ms |
connections - terminals | captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals, captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals, captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals, captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals |
height | 94 mm |
mounting support | top hat type TH35-15 rail conforming to IEC 60715, top hat type TH35-7.5 rail conforming to IEC 60715, wall mount using attached fasteners |
input protection type | internal, electronic |
marking | CE, UL, CSA, EAC, RCM, EFUP 10, TÜV |
width | 43.7 mm |
depth | 73 mm |
vibration resistance | +/- 3.5 mm (f= 5-150 Hz) conforming to IEC 60068-2-6 |
operating altitude | 0...2000 m |
IP degree of protection | IP20 (terminals) conforming to EN/IEC 60529 |
local signalling | 8 LEDs (green/red) for user |
power consumption in W | 0.2 W at 5 V DC, 3.6 W at 24 V DC |
[Ui] rated insulation voltage | 300 V (pollution degree 2) conforming to IEC 60647-5-1 |
associated fuse rating | 4 A gG or gL for relay output conforming to EN/IEC 60947-5-1, 6 A fast blow for relay output conforming to EN/IEC 60947-5-1 |
shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
maximum switching voltage | 230 V utilisation category AC-15 at 50 Hz (relay instantaneous opening), 24 V utilisation category DC-13 (relay instantaneous opening) |
surge withstand | 1 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5 DC, 1 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5 DC |
resistance to electromagnetic fields | 10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3, 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3, 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3 |
resistance to fast transients | 3 kV for power lines (DC) (DC) conforming to EN/IEC 61000-4-4, 2 kV for I/O lines conforming to EN/IEC 61000-4-4 |
electromagnetic emission | radiated emissions - test level: 50 dBµV/m class A ( 24 V DC) at 30-230 Hz conforming to IEC 61131-3, radiated emissions - test level: 57 dBµV/m class A ( 24 V DC) at 230-1000 Hz conforming to IEC 61131-3 |
output thermal current | 6 A per relay for relay output |
resistance to conducted disturbances | 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6 |
storage altitude | 0-3000 m |
resistance to magnetic fields | 30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8 |
safety module application | for emergency stop, switch, sensing mat/edges or safety light curtain monitoring |
synchronisation time between inputs | unlimited, 2 or 4 s depending of wiring configurable by software |
safety level | can reach PL e/category 4 conforming to EN/ISO 13849-1: 2008, can reach PL e/category 4 conforming to EN/ISO 13849-2: 2012, can reach SILCL 3 conforming to EN/IEC 62061: 2005, can reach SIL 3 conforming to EN/IEC 61508: 2010 |