Schneider Electric        
    
    
        
            
    
OsiSense XC Special limit switch XCR - metal spring return rod lever square rod 6 mm - 2X(1NC+NO) - XCRA11
            Out of stock
        
    
            SKU
        
XCRA11
                        Details
                    
                    
The XCR offer is a range of limit switches designed for hoisting and material handling applications.
This product is a complete switch with a metal spring return to off position.
The operator is a metal rod of 200mm long.
The maximum displacement is 55° in each position.
                        More Information
                    
                        | Attribute | Value | 
|---|---|
| SKU | XCRA11 | 
| product certifications | CCC, CSA | 
| ambient air temperature for storage | -40-70 °C | 
| overvoltage category | class I conforming to IEC 61140, class I conforming to NF C 20-030 | 
| ambient air temperature for operation | -25-70 °C | 
| terminals description ISO n°1 | (13-14)NO, (21-22)NC | 
| body type | fixed | 
| sensor design | - | 
| range of product | OsiSense XC | 
| product or component type | Detektor / Sensor | 
| net weight | 1.11 kg | 
| standards | CSA C22.2 No 14, EN 60947-5-1, IEC 60947-5-1, EN 60204-1, IEC 60204-1, NF C 79-130 | 
| mechanical durability | 10000000 cycles | 
| device short name | XCR | 
| range | Limit Switch | 
| short-circuit protection | 10 A cartridge fuse, type gG | 
| contact operation | snap action | 
| positive opening | with | 
| type of approach | lateral approach, 2 directions | 
| minimum actuation speed | 0.01 m/min | 
| contacts insulation form | Zb | 
| electrical connection | screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm² | 
| contact code designation | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A, Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A | 
| height | 95-95 mm | 
| compatibility code | XCR | 
| width | 85 mm | 
| depth | 75 mm | 
| vibration resistance | 9 gn (f= 10-500 Hz) conforming to IEC 60068-2-6 | 
| IP degree of protection | IP54 conforming to IEC 60529 | 
| electrical durability | 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 
| material | metal | 
| fixing mode | by the body | 
| cable entry | 1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9-12 mm conforming to NF C 68-300 | 
| [Ui] rated insulation voltage | 300 V conforming to UL 508, 500 V (pollution degree 3) conforming to IEC 60947-1, 300 V conforming to CSA C22.2 No 14, 500 V (pollution degree 3) conforming to VDE 0110 | 
| protective treatment | TC | 
| contacts type and composition | 2 x (1 NC + 1 NO) | 
| type of operator | spring return rod lever metal square rod 6 mm | 
| shock resistance | 68 gn conforming to IEC 60068-2-27 | 
| series name | special format | 
| head type | rotary head | 
| switch actuation | by any moving part | 
| movement of operating head | rotary | 
| product specific application | for hoisting and mechanical handling applications | 
| maximum actuation speed | 1.5 m/s | 
| number of poles | 4 | 
| maximum resistance across terminals | 25 MOhm conforming to IEC 60255-7 category 3 | 
| body material | zinc alloy | 
| number of steps | 1 | 
| minimum torque for tripping | 0.45 N.m | 
| positive opening minimum torque | 0.75 N.m | 
| maximum displacement angle | 55 °, -55 ° | 
| contact block per direction [control circuit] | 2 per direction | 