OsiSense XC Special limit switch XCR - metal stay put T rods lever square rod 6 mm - 2X(1NC+NO) - XCRF17
This product is part of the XC Special range, an offer of limit switches.
This limit switch is a device that converts a mechanical motion into an electrical control signal.
It has 2 x (1 normally closed + 1 normally opened), snap action contacts with positive opening operation and provides switch actuation by any moving part.
It has a metal square rods lever stay put crossed and supports lateral approach in 2 directions.
The movement of operating head is rotary.
It is furnished with screw clamp terminals for electrical connection and 1 entry tapped for PG13.5 cable gland.
It is an IP54 rated product.
It has a rated operational current of 3A at 240V AC, 0.27A at 250V AC and a conventional enclosed thermal current of 10A.
Its mechanical durability is about 10 million operating cycles, electrical durability is 5 million operating cycles.
This limit switch has a fixed type body which is made of zinc alloy.
Its dimensions are 85mm (Width) x 75mm (Depth) x 95mm (Height) and weighs 1.135kg.
It is suitable for hoisting and mechanical handling applications.
This product is certified by CCC and CSA.
It meets NF C 79-130, CSA C22.2 No 14, EN 60947-5-1, EN 60204-1, IEC 60204-1 and IEC 60947-5-1 standards.
Special format limit switches for severe environments.
Attribute | Value |
---|---|
SKU | XCRF17 |
product certifications | CCC, CSA |
ambient air temperature for storage | -40-70 °C |
overvoltage category | class I conforming to IEC 61140, class I conforming to NF C 20-030 |
ambient air temperature for operation | -25-70 °C |
terminals description ISO n°1 | (13-14)NO, (21-22)NC |
body type | fixed |
sensor design | - |
range of product | OsiSense XC |
product or component type | Detektor / Sensor |
net weight | 1.135 kg |
standards | CSA C22.2 No 14, EN 60947-5-1, IEC 60947-5-1, EN 60204-1, IEC 60204-1, NF C 79-130 |
mechanical durability | 10000000 cycles |
device short name | XCR |
range | Limit Switch |
short-circuit protection | 10 A cartridge fuse, type gG |
contact operation | snap action |
positive opening | with |
type of approach | lateral approach, 2 directions |
minimum actuation speed | 0.01 m/min |
contacts insulation form | Zb |
electrical connection | screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm² |
contact code designation | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A, Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A |
height | 95-95 mm |
compatibility code | XCR |
width | 85 mm |
depth | 75 mm |
vibration resistance | 9 gn (f= 10-500 Hz) conforming to IEC 60068-2-6 |
IP degree of protection | IP54 conforming to IEC 60529 |
electrical durability | 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
material | metal |
fixing mode | by the body |
cable entry | 1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9-12 mm conforming to NF C 68-300 |
[Ui] rated insulation voltage | 300 V conforming to UL 508, 500 V (pollution degree 3) conforming to IEC 60947-1, 300 V conforming to CSA C22.2 No 14, 500 V (pollution degree 3) conforming to VDE 0110 |
protective treatment | TC |
contacts type and composition | 2 x (1 NC + 1 NO) |
type of operator | stay put crossed rods lever metal square rod 6 mm |
shock resistance | 68 gn conforming to IEC 60068-2-27 |
series name | special format |
head type | rotary head |
switch actuation | by any moving part |
movement of operating head | rotary |
product specific application | for hoisting and mechanical handling applications |
maximum actuation speed | 1.5 m/s |
number of poles | 4 |
maximum resistance across terminals | 25 MOhm conforming to IEC 60255-7 category 3 |
body material | zinc alloy |
number of steps | 1 |
minimum torque for tripping | 0.6 N.m |
positive opening minimum torque | 0.7 N.m |
maximum displacement angle | -90 °, 90 ° |
contact block per direction [control circuit] | 1 per direction |