OsiSense XC Standard limit switch XCKD - metal end plunger - 1NC+1NO - snap - M16 - XCKD2110P16
This XCKD compact format (CENELEC EN 50047) limit switch has a metal end plunger and a Zamak body.
This limit switch has a robust Zamak body and head, a modular design allowing easier maintenance and a compact CENELEC EN50047 format.
It is ideal for all industrial machines like packaging, materials handling, conveyors, machining, food and beverage.
It is fixed on the machine by its body, and has a typical 5 million cycles electrical durability in DC-13 utilization category.
It complies with CCC, EN/IEC 60947.-5-1, CSA C22.2 No.14, EN/IEC 60204-1, UL 508 standards and is also RoHS compliant.
Compatible with the well distributed range of common XCK heads, allowing quick replacement in case of damage.
Variable composition design allows late modifications on the switch, for example change of connection type or head.
Attribute | Value |
---|---|
SKU | XCKD2110P16 |
product certifications | CCC, CSA, UL |
ambient air temperature for storage | -40-70 °C |
ambient air temperature for operation | -25-70 °C |
electrical shock protection class | class I conforming to IEC 61140, class I conforming to NF C 20-030 |
terminals description ISO n°1 | (13-14)NO, (21-22)NC |
body type | fixed |
sensor design | compact form B conforming to CENELEC EN 50047 |
range of product | Telemecanique Limit switches XC Standard |
product or component type | Detektor / Sensor |
net weight | 0.18 kg |
standards | CSA C22.2 No 14, EN 60947-5-1, IEC 60947-5-1, UL 508, EN 60204-1, IEC 60204-1 |
mechanical durability | 15000000 cycles |
device short name | XCKD |
range | Limit Switch |
IK degree of protection | IK06 conforming to EN 50102 |
short-circuit protection | 10 A cartridge fuse, type gG |
contact operation | snap action |
positive opening | with |
type of approach | vertical approach, 1 direction |
minimum actuation speed | 0.01 m/min |
contacts insulation form | Zb |
electrical connection | screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm² |
contact code designation | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN 60947-5-1, A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to IEC 60947-5-1 appendix A, Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN 60947-5-1, Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947-5-1 appendix A |
repeat accuracy | 0.1 mm on the tripping points with 1 million operating cycles |
head material | zamak |
height | 65-65 mm |
compatibility code | XCKD |
width | 31 mm |
depth | 30 mm |
vibration resistance | 25 gn (f= 10-500 Hz) conforming to IEC 60068-2-6 |
IP degree of protection | IP67 conforming to IEC 60529, IP66 conforming to IEC 60529 |
electrical durability | 5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 , DC conforming to IEC 60947-5-1 appendix C, 5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 , DC conforming to IEC 60947-5-1 appendix C, 5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 , DC conforming to IEC 60947-5-1 appendix C |
material | metal |
fixing mode | by the body |
device presentation | complete product |
cable entry | 1 entry tapped for M16 x 1.5 cable gland, cable outer diameter: 4-8 mm |
[Ui] rated insulation voltage | 300 V conforming to UL 508, 500 V (pollution degree 3) conforming to IEC 60947-1, 300 V conforming to CSA C22.2 No 14 |
protective treatment | TC |
contacts type and composition | 1 NC + 1 NO |
type of operator | spring return plunger metal |
shock resistance | 50 gn for 11 ms conforming to IEC 60068-2-27 |
series name | standard format |
head type | plunger head |
switch actuation | on end |
movement of operating head | linear |
maximum actuation speed | 0.5 m/s |
number of poles | 2 |
maximum resistance across terminals | 25 MOhm conforming to IEC 60255-7 category 3 |
specific application | compact variable |
positive opening minimum force | 45 N |
body material | zamak |
minimum force for tripping | 15 N |