OsiSense XM pressure sensor XMLG - 0..10 bar - G 1/4A (male) - 24 V - 4..20 mA - XMLG010D21
This product is part of the XM range, an offer of electronic pressure sensors.
The electronic pressure sensor features a G 1/4A (male) for fluid connection.
It supports 4mA to 20mA, 2 wires analogue output signal.
It is furnished with 3-pin M12 male connector for electrical connection.
With a pressure setting range of 0bar to 10bar, a maximum permissible accidental pressure of 22bar and a destruction pressure of 25bar.
This pressure sensor has a rated supply voltage of 12V DC (voltage limits 8V to 33V), 24V DC (voltage limits 8V to 33V) and a current consumption of <20mA.
This pressure sensor has a metal body with stainless steel 303 fluid entry.
Its dimensions are 22.8mm (Diameter) x 48.5mm (Length) x 58.1mm (Height) and weighs 0.095kg.
Its mechanical durability is about 10 million operating cycles.
This pressure switch can be used for monitoring air, fresh water, hydraulic oils and refrigeration fluids.
This product is certified by CSA C22.2 No 14, EAC, UL 508 and CE.
It meets EN/IEC 61326-2-3 standards.
One of the most comprehensive ranges of industrial and power pressure sensors on the market, including a user-friendly electronic transmitter sensor, with unrivalled flexibility of modification during operation.
Ex nautilus control pressure switches, pressure transmitters and power pressure switches for industrial pressure control.
Attribute | Value |
---|---|
SKU | XMLG010D21 |
pressure sensor size | 10 bar |
product certifications | EAC, CSA C22.2 No 14, UL 508 |
ambient air temperature for storage | -40-85 °C |
ambient air temperature for operation | -15-85 °C |
resistance to electrostatic discharge | 15 kV in air conforming to EN/IEC 61000-4-2, 8 kV on contact conforming to EN/IEC 61000-4-2 |
range of product | OsiSense XM |
operating position | any position |
product or component type | Detektor / Sensor |
current consumption | < 20 mA |
net weight | 0.095 kg |
standards | CE, EN/IEC 61326-2-3 |
mechanical durability | 10000000 cycles |
range | Pressure Switch |
[Uimp] rated impulse withstand voltage | 0.5 kV |
[Us] rated supply voltage | 12 V DC (voltage limits: 8-33 V), 24 V DC (voltage limits: 8-33 V) |
electrical connection | 1 male connector M12, 3 pins |
repeat accuracy | +/- 0.1 % of the measuring range |
scale type | fixed differential |
pressure sensor name | XMLG |
response time on output | < 2 ms |
height | 58.1 mm |
vibration resistance | 20 gn (f= 9-2000 Hz) conforming to EN/IEC 60028-2-6 |
IP degree of protection | IP66 conforming to EN/IEC 60529, IP67 conforming to EN/IEC 60529 |
Quantity per set | set of 1 |
type of packing | individual |
protection type | reverse polarity, load short-circuit |
protective treatment | TC |
shock resistance | 25 gn for 11 ms conforming to EN/IEC 60068-2-27 |
NEMA degree of protection | NEMA 4 |
measurement accuracy | +/- 0.3 % of the measuring range |
length | 48.5 mm |
surge withstand | 1 kV 42 Ohm conforming to EN/IEC 61000-4-5, 500 kV 12 Ohm conforming to EN/IEC 61000-4-5 |
resistance to electromagnetic fields | 200 V/m 80-1000 Hz conforming to EN/IEC 61000-4-3 |
resistance to fast transients | 4 kV conforming to EN/IEC 61000-4-4 |
diameter | 22.8 mm |
local display | without |
pressure sensor type | pressure transmitter |
controlled fluid | air (-15-125 °C), corrosive fluid (-15-125 °C), hydraulic oil (-15-125 °C), fresh water (0-125 °C), air,hydraulic oil,corrosive fluid,fresh water |
electrical circuit type | control circuit |
maximum permissible accidental pressure | 22 bar |
materials in contact with fluid | stainless steel type AISI 303, ceramic, FPM (Viton) |
temperature of controlled fluid | -15-125 °C |
destruction pressure | 25 bar |
fluid connection type | G 1/4A (male) conforming to DIN 3852-E |
type of output signal | analogue |
resistance to conducted disturbances | 30 V (0.15-80 Hz) conforming to EN/IEC 61000-4-6 |
resistance to magnetic fields | 30 A/m 50 Hz conforming to EN/IEC 61000-4-8 |
analogue output function | 4...20 mA, 2 wires |
drift of the zero point | +/- 0.015 % of measuring range/°C |
drift of the sensitivity | +/- 0.015 % of measuring range/°C |
pressure setting range | 0-10 bar |