OsiSense XM pressure sensor XMLK - 0..16bar - G 1/4A - 4..20mA - M12 - set of 1 - XMLK016B2D21
Out of stock
SKU
XMLK016B2D21
More Information
| Attribute | Value |
|---|---|
| SKU | XMLK016B2D21 |
| pressure sensor size | 16-16 bar |
| product certifications | EAC, RCM, CSA C22.2 No 14, UL 508 |
| ambient air temperature for storage | -25-80 °C |
| ambient air temperature for operation | 0-80 °C |
| range of product | OsiSense XM |
| operating position | any position |
| product or component type | Detektor / Sensor |
| current consumption | < 20 mA |
| net weight | 0.11 kg |
| standards | CE, EN/IEC 61326-2-3 |
| mechanical durability | 10000000 cycles |
| range | Pressure Switch |
| [Uimp] rated impulse withstand voltage | 0.5 kV |
| [Us] rated supply voltage | 24 V DC SELV (voltage limits: 8-33 V) |
| electromagnetic compatibility | electrostatic discharge immunity test conforming to EN/IEC 61000-4-2 8 kV air, 6 kV contact, susceptibility to electromagnetic fields conforming to EN/IEC 61000-4-3 10 V/m 80...1000 MHz, electrical fast transient/burst immunity test conforming to EN/IEC 61000-4-4 2 kV, 1.2/50 µs shock waves immunity test conforming to EN/IEC 61000-4-5 500 V 12 Ohm, 1 kV 42 Ohm, radiated RF fields conforming to EN/IEC 61000-4-6 10 V 0.15...80 MHz, immunity to magnetic fields conforming to EN/IEC 61000-4-8 30 A/m 50 Hz |
| electrical connection | 1 male connector M12 4 pins |
| repeat accuracy | +/- 1 % of the measuring range |
| scale type | fixed differential |
| pressure sensor name | XMLK |
| response time on output | < 5 ms |
| vibration resistance | 20 gn (f = 9-2000 Hz) conforming to EN/IEC 60068-2-6 |
| IP degree of protection | IP65 conforming to EN/IEC 60529 |
| Quantity per set | set of 1 |
| type of packing | individual |
| protection type | reverse polarity, load short-circuit |
| protective treatment | TC |
| shock resistance | 25 gn for 11 ms conforming to EN/IEC 60068-2-27 |
| NEMA degree of protection | NEMA 4 |
| measurement accuracy | +/- 1 % of the measuring range |
| length | 67.5 mm |
| accuracy | 0.1 % of the measuring range |
| diameter | 36 mm |
| local display | without |
| pressure sensor type | pressure transmitter |
| controlled fluid | air (0-80 °C), fresh water (0-80 °C), air,fresh water |
| electrical circuit type | control circuit |
| maximum permissible accidental pressure | 32 bar |
| materials in contact with fluid | stainless steel type AISI 303, nitrile (NBR), ceramic |
| temperature of controlled fluid | 80-80 °C |
| destruction pressure | 48 bar |
| fluid connection type | G 1/4A (male) conforming to DIN 3852-E |
| type of output signal | analogue |
| analogue output function | 4...20 mA, 2-wire |
| drift of the zero point | +/- 0.03 % of measuring range/°K |
| drift of the sensitivity | +/- 0.04 % of measuring range/°K |
| pressure setting range | 0-16 bar |