Schneider Electric
OsiSense XM pressure sensor XMP - 12 bar - G 3/8 female - 2 NC - without control type - XMPA12B2242
Out of stock
SKU
XMPA12B2242
Details
The XMP switches are electromechanical pressure switches for control circuits.
They are used to control the pressure of water and air.
It is an IP54 switch with an adjustable differential for regulation between 2 thresholds, without decompression valve.
It is a bare case switch, without decompression valve.
Ajustable range of switching point: from 1.3bar to 12bar or from 18.85psi to 174psi.
2 NC contacts, G 3/8 female fluid connection, 2 entries incorporating n°13 cable gland.
More Information
Attribute | Value |
---|---|
SKU | XMPA12B2242 |
pressure sensor size | 12 bar |
product certifications | EAC |
ambient air temperature for storage | -40-70 °C |
ambient air temperature for operation | -25-70 °C |
electrical shock protection class | class I conforming to IEC 60536 |
terminals description ISO n°1 | (1-2)NC, (3-4)NC |
pressure switch type of operation | regulation between 2 thresholds |
adjustment range high setting | 1.3-12 bar |
range of product | OsiSense XM |
operating position | any position |
product or component type | Detektor / Sensor |
net weight | 0.43 kg |
standards | CE, EN/IEC 60947-4-1 |
mechanical durability | 1000000 cycles |
range | Pressure Switch |
electrical connection | screw-clamp terminals, clamping capacity: minimum : 2 x 4 mm² |
repeat accuracy | 3.5 % |
scale type | adjustable differential |
possible differential minimum at high setting | 1.7 bar |
possible differential maximum at high setting | 8.4 bar |
pressure sensor name | XMP |
height | 106 mm |
width | 57 mm |
depth | 98 mm |
vibration resistance | 3 gn conforming to IEC 60068-2-6 (f = 10-500 Hz) |
IP degree of protection | IP54 conforming to EN/IEC 60529 |
electrical durability | 1000000 cycles 1.5 kW, operating rate <10 cyc/mn, load factor: 0.4 , 400 V AC 3 phases, 500000 cycles 3 kW, operating rate <10 cyc/mn, load factor: 0.4 , 400 V AC 3 phases, 600000 cycles 1.5 kW, operating rate <10 cyc/mn, load factor: 0.4 , 230 V AC 3 phases, 700000 cycles 2.2 kW, operating rate <10 cyc/mn, load factor: 0.4 , 400 V AC 3 phases |
control type | without |
sale per indivisible quantity | 1 |
cable entry | 2 entries incorporating Pg 13.5 plastic cable gland, cable outer diameter: 9-13 mm conforming to NF C 68-300 |
[Ui] rated insulation voltage | 500 V conforming to EN/IEC 60947-1 |
maximum operating rate | 10 cyc/mn |
contacts type and composition | 2 NC snap action |
shock resistance | 50 gn conforming to IEC 60068-2-27 |
enclosure material | PA impregnated with fibreglass |
product specific application | - |
maximum resistance across terminals | 25 MOhm conforming to IEC 60255-7 category 3, 25 mOhm conforming to NF C 93-050 method A |
local display | without |
pressure sensor type | electromechanical pressure sensor |
pressure actuator | diaphragm |
terminal block type | 4 terminals |
controlled fluid | air (0-70 °C), fresh water (0-70 °C), sea water (0-70 °C) |
setting | knurled knob and nut |
electrical circuit type | power circuit |
adjustable range of switching point on falling pressure | 0.3-10.3 bar |
materials in contact with fluid | chromated zinc alloy, canvas covered nitrile |
destruction pressure | 30 bar |
fluid connection type | G 3/8 (female) conforming to ISO 228 |
possible differential minimum at low setting | 1 bar |
type of decompression valve | without |
Technical Documents