Schneider Electric
OsiSense XM pressure switch XMLA 10 bar - fixed scale 1 threshold - 1 C/O - XMLA010A2S11
Out of stock
SKU
XMLA010A2S11
Details
This XMLA electromechanical pressure switch has a fixed differential for detection of a single threshold and a zinc alloy body with a range scale window.
This pressure switch is designed for detection of a single pressure threshold in air, fresh water, hydraulic oils, corrosive fluids and viscous products up to 70°C.
It is fixed directly on tubage.
It provides zinc alloy enclosure for robust performance.
5 million cycles mechanical durability for minimum required maintenance on your pressurized fluid circuits.
It complies with CCC, EN/IEC 60947-5-1, CSA C22.2 No.14, LROS, UL 508, EAC, BV.
More Information
Attribute | Value |
---|---|
SKU | XMLA010A2S11 |
pressure sensor size | 10 bar |
product certifications | EAC, CCC, LROS (Lloyds register of shipping), BV, CSA, UL |
ambient air temperature for storage | -40-70 °C |
ambient air temperature for operation | -25-70 °C |
electrical shock protection class | class I conforming to NF C 20-030, class I conforming to IEC 1140, class I conforming to IEC 536 |
terminals description ISO n°1 | (13-14-11-12)OF |
pressure switch type of operation | detection of 1 single threshold |
adjustable range of switching point on rising pressure | 0.6-10 bar |
maximum permissible pressure - per cycle | 12.5 bar |
range of product | OsiSense XM |
operating position | any position |
product or component type | Detektor / Sensor |
net weight | 0.685 kg |
standards | CE, CSA C22.2 No 14, UL 508, EN/IEC 60947-5-1 |
mechanical durability | 5000000 cycles |
device short name | XMLA |
range | Pressure Switch |
contacts material | silver contacts |
short-circuit protection | 10 A cartridge fuse, type gG (gl) |
electrical connection | screw-clamps terminals, 1 x 0.5...2 x 2.5 mm², 1 connector Pg 13 |
repeat accuracy | 2 % |
scale type | fixed differential |
height | 113 mm |
width | 35 mm |
depth | 75 mm |
vibration resistance | 4 gn conforming to IEC 60068-2-6 (f = 30-500 Hz) |
IP degree of protection | IP66 conforming to EN/IEC 60529 |
[In] rated current | 3 A, B300, AC-15 (Ue = 120 V) conforming to EN/IEC 60947-5-1, 1.5 A, B300, AC-15 (Ue = 240 V) conforming to EN/IEC 60947-5-1, 0.1 A, R300, DC-13 (Ue = 250 V) conforming to EN/IEC 60947-5-1 |
cable entry | cable gland 9-13 mm |
[Ui] rated insulation voltage | 300 V conforming to UL 508, 300 V conforming to CSA C22.2 No 14, 500 V conforming to EN/IEC 60947-1 |
maximum operating rate | 120 cyc/mn |
protective treatment | TC standard version |
contacts type and composition | 1 C/O |
shock resistance | 50 gn conforming to IEC 60068-2-27 |
AWG gauge | AWG 20...AWG 14 |
enclosure material | zinc alloy |
product specific application | - |
maximum resistance across terminals | 25 mOhm conforming to IEC 255-7 category 3, 25 mOhm conforming to NF C 93-050 method A |
local display | with |
pressure sensor type | electromechanical pressure sensor |
pressure actuator | diaphragm |
terminal block type | 4 terminals |
controlled fluid | air (0-70 °C), fresh water (0-70 °C), hydraulic oil (0-70 °C), air,hydraulic oil,fresh water |
natural differential at high setting | 0.5 bar (+/- 0.05 bar) |
setting | external |
electrical circuit type | control circuit |
auxiliary contacts operation | snap action |
adjustable range of switching point on falling pressure | 0.1-9.5 bar |
maximum permissible accidental pressure | 22.5 bar |
materials in contact with fluid | FPM, FKM, zinc alloy |
temperature of controlled fluid | 0-70 °C |
destruction pressure | 45 bar |
natural differential at low setting | 0.5 bar (+/- 0.05 bar) |
fluid connection type | G 1/4 (female) conforming to ISO 228 |
Technical Documents