Schneider Electric
OsiSense XM pressure switch XMLA 300 bar - fixed scale 1 threshold - 1 C/O - XMLA300D2S12
Out of stock
SKU
XMLA300D2S12
Details
This XMLA electromechanical pressure switch has an adjustable differential for detection of a single threshold and a zinc alloy body with a range scale window.
This pressure switch is designed for detection of a single pressure threshold in hydraulic oils up to 160°C.
It is fixed directly on tubage.
It provides zinc alloy enclosure for robust performance.
6 million cycles mechanical durability for minimum required maintenance on your pressurized fluid circuits.
It complies with CCC, EN/IEC 60947-5-1, CSA C22.2 No.14, LROS, UL 508, EAC, BV.
It is designed for very high pressures up to 300bar, this makes it ideal for hydraulic presses, water jet cutting machines.
More Information
Attribute | Value |
---|---|
SKU | XMLA300D2S12 |
pressure sensor size | 300 bar |
product certifications | EAC, CCC, LROS (Lloyds register of shipping), BV, CSA, UL |
ambient air temperature for storage | -40-70 °C |
ambient air temperature for operation | -25-70 °C |
electrical shock protection class | class I conforming to NF C 20-030, class I conforming to IEC 1140, class I conforming to IEC 536 |
terminals description ISO n°1 | (13-14-11-12)OF |
pressure switch type of operation | detection of 1 single threshold |
adjustable range of switching point on rising pressure | 20-300 bar |
maximum permissible pressure - per cycle | 375 bar |
range of product | OsiSense XM |
operating position | any position |
product or component type | Detektor / Sensor |
net weight | 0.75 kg |
standards | CE, CSA C22.2 No 14, UL 508, EN/IEC 60947-5-1 |
mechanical durability | 3000000 cycles |
device short name | XMLA |
range | Pressure Switch |
contacts material | silver contacts |
short-circuit protection | 10 A cartridge fuse, type gG (gl) |
electrical connection | screw-clamps terminals, 1 x 0.5...2 x 2.5 mm², 1 connector ISO M20 |
repeat accuracy | 2 % |
scale type | fixed differential |
height | 113 mm |
width | 35 mm |
depth | 75 mm |
vibration resistance | 4 gn conforming to IEC 60068-2-6 (f = 30-500 Hz) |
IP degree of protection | IP66 conforming to EN/IEC 60529 |
[In] rated current | 3 A, B300, AC-15 (Ue = 120 V) conforming to EN/IEC 60947-5-1, 1.5 A, B300, AC-15 (Ue = 240 V) conforming to EN/IEC 60947-5-1, 0.1 A, R300, DC-13 (Ue = 250 V) conforming to EN/IEC 60947-5-1 |
cable entry | cable gland 7-13 mm |
[Ui] rated insulation voltage | 300 V conforming to UL 508, 300 V conforming to CSA C22.2 No 14, 500 V conforming to EN/IEC 60947-1 |
maximum operating rate | 60 cyc/mn |
protective treatment | TC standard version |
contacts type and composition | 1 C/O |
shock resistance | 50 gn conforming to IEC 60068-2-27 |
AWG gauge | AWG 20...AWG 14 |
enclosure material | zinc alloy |
product specific application | - |
maximum resistance across terminals | 25 mOhm conforming to IEC 255-7 category 3, 25 mOhm conforming to NF C 93-050 method A |
local display | with |
pressure sensor type | electromechanical pressure sensor |
pressure actuator | piston |
terminal block type | 4 terminals |
controlled fluid | hydraulic oil (0-160 °C), hydraulic oil |
natural differential at high setting | 35 bar (+/- 6 bar) |
setting | external |
electrical circuit type | control circuit |
auxiliary contacts operation | snap action |
adjustable range of switching point on falling pressure | 3.5-265 bar |
maximum permissible accidental pressure | 675 bar |
materials in contact with fluid | brass, FPM, FKM, PTFE, steel |
temperature of controlled fluid | 0-160 °C |
destruction pressure | 1350 bar |
natural differential at low setting | 16.5 bar (+/- 3 bar) |
fluid connection type | G 1/4 (female) conforming to ISO 228 |
Technical Documents