Phaseo Regulated Power Supply, 100-240V AC, 12V 2.1 A, single phase, Modular - ABLM1A12021
This ABLM regulated switch mode power supply (SMPS) supplies direct current voltage.
It has a rated input of 100V to 240V AC, a rated output current of 2,1A at 12V DC and a rated power output of 25W.
It is ideal for supplying DC voltage necessary for automation equipment designed for applications in industrial, commercial and residential applications such as conveying, packaging, control, food & beverage, mining, oil & gas and water.
It installs on omega rail or fixing by screw.
Its width is 30mm, its height is 75mm, its depth is 92,8mm.
It ensures a protection against overloads and short-circuits with automatic restart after the source of overload/short-circuit has been corrected.
It weighs 0.170kg.
It is a power supply for industrial use, rail mounting.
It conforms to EN62368-1, ENIEC61010-1/2-201, ENIEC61204-3, EN61000-6-1/2/3/4, EN61000-3-2-3, UL62368-1, UL61010-2-201/-1-201, CSAC22.2No62368-1/No61010-2-201/No61010-1 standards.
It is certified by CE, CUL listed/recognized, RCM, CBscheme.
The Acti9 iC60 range of Miniature Circuit Breakers is recommanded for its protection.
The type of protection is 4A, B or C curve.
It has in the front face a LED indicating presence of DC output voltage, and a QR code for access to the latest technical documentation.
Thanks to their modular housing, they can be installed either in enclosures or industrial panels by clipping on omega (DIN) rail.
It brings energy to your automated systems.
Designed for simple machines and applications, modular power supplies are primarily appreciated for their extreme compactness.
Attribute | Value |
---|---|
SKU | ABLM1A12021 |
product certifications | EAC, CE, RCM, CB Scheme, KC, cUL listed, cUL recognized, NEC: class 2 |
relative humidity | 0-95 % without condensation |
ambient air temperature for storage | -40-85 °C |
overvoltage category | II |
pollution degree | 2 |
ambient air temperature for operation | -25-55 °C (without current derating), 55-70 °C (with current derating of 2.67 % per °C) |
line and load regulation | < 0.5 %line, < 1 %load |
electrical shock protection class | class II without PE connection |
input voltage | 100...240 V AC single phase, 100...240 V AC 2 phases |
output voltage | 12 V DC |
range of product | Modicon Power Supply |
power supply output current | 2.1 A |
rated power in W | 25 W |
product or component type | Relay & Power Supply |
current consumption | < 0.8 A 115 V AC, < 0.6 A 230 V AC |
net weight | 0.17 kg |
standards | EN 62368-1, EN 61010-2-201, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3, UL 62368-1, UL 61010-1, UL 61010-2-201, CSA C22.2 No 62368-1, CSA C22.2 No 61010-1, CSA C22.2 No 61010-2-201, EN/IEC 61010-1, EN/IEC 61204-3 |
range | Power Supply |
electromagnetic compatibility | immunity to electrostatic discharge - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2, immunity to electrostatic discharge - test level: 9 kV (air discharge) conforming to EN/IEC 61000-4-2, immunity to fast transients - test level: 4 kV (on input-output) conforming to EN/IEC 61000-4-4, surge immunity test - test level: 3 kV (between power supply and earth) conforming to EN/IEC 61000-4-5, surge immunity test - test level: 1.5 kV (between phases) conforming to EN/IEC 61000-4-5, immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to EN/IEC 61000-4-8, disturbing field emission conforming to EN 55016-2-3, limits for harmonic current emissions conforming to EN 61000-3-2, conducted disturbance emission conforming to EN 55016-1-2, conducted disturbance emission conforming to EN 55016-2-1, electromagnetic field immunity test - test level: 10 V/m (80 MHz...2 GHz) conforming to EN/IEC 61000-4-3, electromagnetic field immunity test - test level: 5 V/m (2...2.7 GHz) conforming to EN/IEC 61000-4-3, electromagnetic field immunity test - test level: 3 V/m (2.7...6 GHz) conforming to EN/IEC 61000-4-3, immunity to conducted disturbances - test level: 10 Vrms (0.15...80 MHz) conforming to EN/IEC 61000-4-6, immunity to voltage dips - test level: 100 % (1 cycle) conforming to EN/IEC 61000-4-11, immunity to voltage dips - test level: 60 % (10 cycles) conforming to EN/IEC 61000-4-11, immunity to voltage dips - test level: 30 % (25 cycles) conforming to EN/IEC 61000-4-11 |
service life | 10 year(s) |
variant option | modular |
output coupling | serial |
connections - terminals | screw connection: 0.5...1.5 mm², (AWG 20...AWG 16) without wire end ferrule for input/output, screw connection: 0.5...1 mm², (AWG 20...AWG 18) with wire end ferrule for input/output |
output protection type | against overload and short-circuits, protection technology: automatic reset, against over temperature, protection technology: manual reset, against overvoltage, protection technology: manual reset |
height | 91 mm |
meantime between failure [MTBF] | 2500000 h at 25 °C, full load, 1000000 h at 55 °C, 80 % load |
power dissipation in W | 4.6 W |
status LED | 1 LED (green)output voltage |
holding time | > 20 ms 115 V AC, > 60 ms 230 V AC |
output voltage limits | 12...15 V |
mounting support | top hat type TH35-15 rail conforming to IEC 60715, top hat type TH35-7.5 rail conforming to IEC 60715, double-profile DIN rail, panel mounting |
input protection type | external protection (recommended) 20 A Curve C, integrated fuse (not interchangeable) 3.15 A, external protection (recommended) 20 A Curve B, external protection (recommended) 4 A Curve B, external protection (recommended) 4 A Curve C |
efficiency | 85 % at 115 V AC, 85 % at 230 V AC |
width | 36 mm |
depth | 55.6 mm |
power supply type | regulated switch mode |
inrush current | 25 A at 115 V, 50 A at 230 V |
input voltage limits | 90...264 V AC |
vibration resistance | 3 mm (f= 2-9 Hz) conforming to IEC 60721-3-3, 10 m/s² (f= 9-200 Hz) conforming to IEC 60721-3-3 |
operating altitude | < 2000 m overvoltage category III, 2000 m...5000 m overvoltage category II |
dielectric strength | 3000 V AC input/output |
IP degree of protection | IP20 |
response time | < 2 s |
earthing system | TT, TN, IT |
shock resistance | 100 m/s² for 11 ms |
enclosure material | plastic |
electromagnetic emission | conducted emissions conforming to EN 61000-6-3, radiated emissions conforming to EN 61000-6-4 |
residual ripple | < 100 mV |
load capacitance | 3000 µF |
network frequency limits | 50-60 Hz |
maximum leakage current | 0.25 mA 240 V AC |
power factor | 0.48 at 115 V AC, 0.38 at 230 V AC |