This ABLS regulated switch mode power supply (SMPS) supplies direct current voltage.

It has a rated input of 100V to 240V AC and 140 V to 340 V DC, a rated output current of 10A at 24V DC and a rated power output of 240W.

It is ideal for supplying DC voltage necessary for automation equipment designed for applications in industrial, commercial and residential applications such as conveying, packaging, control, food & beverage, mining, oil & gas and water.

It installs on omega rail or fixing by screw.

Its width is 60mm, its height is 123,6mm, its depth is 117,6mm.

It ensures a protection against overloads and short-circuits with automatic restart after the source of overload/short-circuit has been corrected.

It weighs 0.800kg.

It is a power supply for industrial use, rail mounting.

It conforms to EN62368-1, ENIEC61010-1, ENIEC61204-3, EN61000-6-1/2/3/4, EN61000-3-2-3, UL62368-1, UL61010-2-201/-1-201, CSAC22.2No62368-1 standards.

It is certified by CE, CUL listed/recognized, RCM, CBscheme.

The Acti9 iC60 range of Miniature Circuit Breakers is recommanded for its protection.

The type of protection is 6A, B or C curve.

It has in the front face a LED indicating presence of DC output voltage, and a QR code for access to the latest technical documentation.

Thanks to its book housing, it can be installed either in enclosures or industrial panels by clipping on omega (DIN) rail.

It brings energy to your automated systems.

Designed for simple machines and applications, modular power supplies are primarily appreciated for their extreme compactness.

More Information
More Information
Attribute Value
SKU ABLS1A24100
product certifications EAC, CE, RCM, CB Scheme, KC, cUL listed, cUL recognized
relative humidity 0-95 % without condensation
ambient air temperature for storage -40-85 °C
overvoltage category II
pollution degree 2
ambient air temperature for operation 40-70 °C (with current derating of 1.8 % per °C), 50-70 °C (with current derating of 2.5 % per °C)
environmental characteristic 3M4 conforming to IEC 60721-3-3
line and load regulation < 0.5 %line, < 1 %load
electrical shock protection class class I
input voltage 100...240 V AC single phase, 100...240 V AC 2 phases, 140...340 V DC
output voltage 24 V DC
range of product Modicon Power Supply
power supply output current 10 A
rated power in W 240 W
product or component type Relay & Power Supply
current consumption < 1.4 A 230 V AC, < 2.8 A 115 V AC, < 2.4 A 140 V DC
net weight 0.8 kg
standards UL 508, EN 62368-1, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3, UL 62368-1, CSA C22.2 No 62368-1, EN/IEC 61204-3, CSA C22.2 No 107.1
range Power Supply
electromagnetic compatibility immunity to electrostatic discharge - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2, immunity to electrostatic discharge - test level: 9 kV (air discharge) conforming to EN/IEC 61000-4-2, immunity to conducted RF disturbances - test level: 10 V/m (80 MHz...2 GHz) conforming to EN/IEC 61000-4-3, immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to EN/IEC 61000-4-3, immunity to conducted RF disturbances - test level: 3 V/m (2.7...6 GHz) conforming to EN/IEC 61000-4-3, immunity to fast transients - test level: 4 kV (on input-output) conforming to EN/IEC 61000-4-4, surge immunity test - test level: 3 kV (between power supply and earth) conforming to EN/IEC 61000-4-5, surge immunity test - test level: 1.5 kV (between phases) conforming to EN/IEC 61000-4-5, immunity to conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6, immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to EN/IEC 61000-4-8, immunity to voltage dips conforming to EN/IEC 61000-4-11, disturbing field emission conforming to EN 55016-2-3, limits for harmonic current emissions conforming to EN 61000-3-2, conducted disturbance emission conforming to EN 55016-1-2, conducted disturbance emission conforming to EN 55016-2-1
service life 10 year(s)
variant option optimized
output coupling parallel, serial
connections - terminals screw connection: 0.5...4 mm², (AWG 20...AWG 12) without wire end ferrule for output, screw connection: 0.5...2.5 mm², (AWG 20...AWG 14) with wire end ferrule for output, screw connection: 0.75...4 mm², (AWG 18...AWG 12) without wire end ferrule for input, screw connection: 0.75...4 mm², (AWG 18...AWG 12) with wire end ferrule for input
output protection type against overload and short-circuits, protection technology: automatic reset, against over temperature, protection technology: manual reset, against overvoltage, protection technology: manual reset
height 123.6 mm
meantime between failure [MTBF] 700000 h at 25 °C, full load conforming to SR 332
power dissipation in W 36 W
status LED 1 LED (green)output voltage
holding time > 20 ms 115 V AC, > 20 ms 230 V AC
output voltage limits 22...28 V
mounting support top hat type TH35-15 rail conforming to IEC 60715, top hat type TH35-7.5 rail conforming to IEC 60715, double-profile DIN rail
input protection type integrated fuse (not interchangeable) 6.3 A, external protection (recommended) 20 A Curve C, external protection (recommended) 20 A Curve B, external protection (recommended) 6 A Curve C, external protection (recommended) 6 A Curve B
efficiency 88 % at 230 V AC, 85 % at 115 V AC
width 60 mm
depth 117.6 mm
power supply type regulated switch mode
inrush current 30.0 A at 115 V, 60.0 A at 230 V
input voltage limits 85...264 V AC, 120...375 V DC
vibration resistance 3 mm (f= 2-9 Hz) conforming to IEC 60068-2-6, 10 m/s² (f= 9-200 Hz) conforming to IEC 60068-2-6
operating altitude < 5000 m
dielectric strength 3000 V AC input to output
IP degree of protection IP20
response time < 1 s
earthing system TT, TN, IT
shock resistance 100 m/s² for 11 ms
enclosure material aluminium
electromagnetic emission conducted emissions conforming to EN 61000-6-3, radiated emissions conforming to EN 61000-6-4
residual ripple < 120 mV
load capacitance 8000 µF
network frequency limits 50-60 Hz
maximum leakage current 1 mA 240 V AC
power factor 0.95 at 115 V AC, 0.95 at 230 V AC