PM5350 power monitor - METSEPM5350
This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display.
The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 32 samples per cycle.
The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to 15th Harmonic.
Include a non-volatile memory for several parameters and alarms.
The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 85 to 265 VAC and 100 to 300 VDC.
Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations.
The range of measurement voltage between Phases is 20V AC to 480V AC, CAT III or 20V AC to 690V AC, CAT II at 45 Hz to 70 Hz.
The range of measurement voltage between Phase and Neutral is 20V AC to 277V AC, CAT III or 20V AC to 400V AC, CAT II at 45 Hz to 70 Hz.
Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support.
The meter also has four digital inputs and dual relay outputs.
Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 2.24 inches (57 millimetres), height 3.78 inches (96 millimetres) and product weight 8.8 onces (250 g).
Attribute | Value |
---|---|
SKU | METSEPM5350 |
product certifications | CE, cULus |
relative humidity | 0-95 % at 50-50 °C |
ambient air temperature for storage | -25-70 °C |
overvoltage category | III |
pollution degree | 2 |
ambient air temperature for operation | -40-85 °C |
product or component type | Meter & Manajemen Energi |
net weight | 0.25 kg |
mounting mode | flush-mounted |
standards | IEC 61010-1 |
device short name | PM5350 |
range | Power Meter |
product name | PowerLogic PM5350 |
[Us] rated supply voltage | 85...265 V AC 45...65 Hz, 100...300 V DC |
electromagnetic compatibility | electrostatic discharge conforming to IEC 61000-4-2, electrical fast transient/burst immunity test conforming to IEC 61000-4-4, conducted RF disturbances conforming to IEC 61000-4-6, limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3, immunity to impulse waves conforming to IEC 61000-4-12, susceptibility to electromagnetic fields conforming to IEC 61000-4-3, 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5, conducted and radiated emissions class A conforming to EN 55011, limits for harmonic current emissions conforming to IEC 61000-3-2 |
type of measurement | voltage, current, frequency, power factor, energy, apparent power, active power, phase angle, reactive power |
analogue input type | current 0.05...9 A (impedance <= 0.3 Ohm) |
network frequency | 50 Hz, 60 Hz |
connections - terminals | voltage circuit: screw terminal block4, control circuit: screw terminal block2, current transformer: screw terminal block6, input/output circuit: screw terminal block6, relay output: screw terminal block4, Ethernet network: RJ45 connector |
height | 96 mm |
compatibility code | PM5350 |
width | 96 mm |
depth | 44 mm |
operating altitude | 0...3000 m |
IP degree of protection | IP30 back: conforming to IEC 60529, IP51 front face: conforming to IEC 60529 |
[In] rated current | 1 A, 5 A |
poles description | 1P + N, 3P, 3P + N |
device application | power monitoring |
market segment | buildings small building cost management: billing: main incomer, buildings small building cost management: billing: sub feeder, buildings medium building cost management: billing: main incomer, buildings medium building cost management: billing: sub feeder, buildings large building cost management: billing: main incomer, buildings large building cost management: billing: sub feeder, buildings multi-site cost management: billing: main incomer, buildings multi-site cost management: billing: sub feeder, datacenter cost management: billing: main incomer, datacenter cost management: billing: sub feeder, healthcare cost management: billing: main incomer, healthcare cost management: billing: sub feeder, industry cost management: billing: main incomer, industry cost management: billing: sub feeder, buildings small building cost management: cost allocation: main incomer, buildings small building cost management: cost allocation: sub feeder, buildings medium building cost management: cost allocation: main incomer, buildings medium building cost management: cost allocation: sub feeder, buildings large building cost management: cost allocation: main incomer, buildings large building cost management: cost allocation: sub feeder, buildings multi-site cost management: cost allocation: main incomer, buildings multi-site cost management: cost allocation: sub feeder, datacenter cost management: cost allocation: main incomer, datacenter cost management: cost allocation: sub feeder, healthcare cost management: cost allocation: main incomer, healthcare cost management: cost allocation: sub feeder, industry cost management: cost allocation: main incomer, industry cost management: cost allocation: sub feeder, buildings small building network management: main incomer, buildings small building network management: sub feeder, buildings medium building network management: main incomer, buildings medium building network management: sub feeder, buildings large building network management: sub feeder, buildings multi-site network management: sub feeder, datacenter network management: sub feeder, healthcare network management: sub feeder, industry network management: sub feeder |
measurement voltage | 20-690 V AC phase to phase, 20-400 V AC phase to neutral |
display type | backlit LCD |
type of installation | indoor installation |
maximum power consumption in VA | 9.6 VA |
measurement current | 0-5 A, 0-1 A |
frequency measurement range | 45-70 Hz |
communication port support | terminal block: RS485 |
power quality analysis | total harmonic distortion, total demand distortion |
sampling rate | 32 samples/cycle |
number of outputs | 2 relay |
communication port protocol | JBUS, Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds |
number of inputs | 4 digital |
information displayed | tariff (4) |
measurement accuracy | power factor +/- 0.005, current 0.3 %, voltage 0.3 %, frequency 0.05 % |
data recording | min/max of instantaneous values, alarms |
accuracy class | class 0.5S active energy conforming to IEC 62053-22, class 2 reactive energy conforming to IEC 61557-12, class 0.5 active energy conforming to IEC 61557-12, class 3 reactive energy conforming to IEC 62053-23, class 0.5 power conforming to IEC 61557-12 |
display resolution | 6 lines |
ride-through time | 80 ms 120 V AC typical, 100 ms 230 V AC typical, 100 ms 415 V AC typical |