Schneider Electric

PowerTag Monoconnect, 250 A, 3P+N - LV434021

Out of stock
SKU
LV434021
38%
Special Price Rp 5.047.947 Regular Price Rp 8.141.850
Details

This PowerTag Energy M250 3P+N is a wireless communication energy sensor.

With its Monoconnect design, it is dedicated to Compact NSX 100/160/250, Compact NS 100/160/250, Compact INS250 and Compact INV 100/160/200/250.

It has to be associated with a concentror or a gateway to provide circuit monitoring and diagnosis down to load level.

It is designed specifically for Energy Management, Load Monitoring and Power Availability applications.

It incorporates accurate real-time measurements of active, and reactive energy, active, reactive and apparent power, current, voltage and power factor.

In case of power outage, it sends a voltage loss alarm and the current-per-phase value before being de-energized.

PowerTag Energy M250 complies with IEC 61557-12 standard.

It is a PMD-II/DD/K70/1.

The Performance category is Class 1.

The Imax maximum current is 250A.

The Ib Base current is 40A.

The Saturation current is 500A and the Ist Starting current is 160mA.

The Un Rated voltages are Phase-to-neutral 230VAC +/- 20% and Phase-to-phase 400VAC +/- 20%.

The maximum consumption is below or equal to 3.7VA.

It can be mounted directly on the bottom side of the circuit breaker or Vigi add-on terminals, or top or bottom side of the plug-in base if any.

The product color is grey (RAL7016).

The weight is 300g.

The degree of protection is IP20 and IK07.

The operating temperature is between -25°C to +70°C.

The storage temperature is between -50°C to +85°C.

More Information
More Information
Attribute Value
SKU LV434021
relative humidity 0-95 % at 55-55 °C conforming to IEC 60721-3-3
ambient air temperature for storage -50-85 °C
overvoltage category IV conforming to IEC 61010-1
pollution degree 3
ambient air temperature for operation -25-70 °C
environmental characteristic indoor use
quality labels CE
product or component type Meter & Manajemen Energi
net weight 300 g
mounting mode bolt-on
standards IEC 61557-12, IEC 61010
range PowerTag
range compatibility Compact NSX Compact NSX100...250, Compact NS Compact NS100...250, Compact INV Compact INV100...250, Compact INS Compact INS250-100...250
IK degree of protection IK07 conforming to IEC 60068-2-75 test Ehb
product name PowerTag M250
type of measurement voltage, current, power factor, active and reactive power, active and reactive energy, apparent power
measurement category category III conforming to IEC 61010-2-030
starting current 160 mA
transmission support medium radio frequency 2.4-2.4835 GHz conforming to IEEE 802.15.4 (11-26 ) transmission time < 5 ms
saturation current 500 A
form factor monoconnect
maximum emission power 10 mW
Concentrator compatibility Acti9 PowerTag Link C, Acti9 PowerTag Link, Acti9 PowerTag Link HD, Harmony Hub, Acti9 Smartlink SI B, Acti9 Smartlink SI D, Wiser IP module
Event management voltage loss with measured current at voltage loss
[Ib] basic current 40 A
network frequency 50 Hz, 60 Hz
height 57 mm
mounting support on circuit breaker
width 140 mm
depth 86 mm
vibration resistance 3M4 conforming to IEC 60721-3-3
operating altitude 0...2000 m
IP degree of protection IP20
poles description 3P + N
colour dark grey (RAL 7016)
tightening torque 10-10 N.m
[Ue] rated operational voltage 230 V AC, +/- 20 %, between phase and neutral, 400 V AC, +/- 20 %, between phases
product destination switchboard
connection pitch 35 mm
maximum power consumption in VA 3.7 VA
metering type frequency 45...65 Hz, power factor 0...1: class 1 at 25 °C conforming to IEC 61557-12, active energy Ep IN/OUT/tot 0...281 x 10exp(9) kWh: class 1 at 25 °C conforming to IEC 61557-12, reactive energy Ep IN/OUT/tot 0...281 x 10exp(9) kVARh: class 2 at 25 °C conforming to IEC 61557-12, voltage U12, U23, U31 320...480 V: class 0.5 at 25 °C conforming to IEC 61557-12, voltage V1N, V2N, V3N 184...276 V: class 0.5 at 25 °C conforming to IEC 61557-12, current I1, I2, I3, Iavg 8...250 A: class 1 at 25 °C conforming to IEC 61557-12, apparent power S, S1, S2, S4 88 VA...416 kVA: class 2 at 25 °C conforming to IEC 61557-12, active power P, P1, P2, P4 88 W...416 kW: class 1 at 25 °C conforming to IEC 61557-12, reactive power Q, Q1, Q2, Q4 88 VAR...416 kVAR: class 2 at 25 °C conforming to IEC 61557-12
accuracy class class 1 active energy conforming to IEC 61557-12, class 2 reactive energy conforming to IEC 61557-12, class 1 active power conforming to IEC 61557-12, class 2 reactive power conforming to IEC 61557-12, class 2 apparent power conforming to IEC 61557-12, class 1 current conforming to IEC 61557-12, class 0.5 voltage conforming to IEC 61557-12, class 1 power factor conforming to IEC 61557-12
product specific application energy management, overload alarm, power factor, load monitoring, circuit monitoring
[Imp] maximum permanent current 1.2 x In
mounting location bottom
directives 2014/53/EU - radio equipment directive
max current 250 A