Schneider Electric

Preventa XY2C e-stop rope pull switch XY2CH - 1NC+1NO - booted pushbutton - XY2CH13250

Out of stock
SKU
XY2CH13250
45%
Special Price Rp 2.312.574 Regular Price Rp 4.204.680
Details

This XY2CH Emergency Stop Rope pull Switch is designed with a right hand side or a left hand side anchor point, allowing operator to trigger the stop of potentially dangerous machines at any point of its working area.

It operates with a maximum rope length of 30 meters.

It has a Zamak body with a booted pushbutton reset, Chloroprene bellows, no pilot light, and 1 normally open and 1 normally closed slow break contacts.

Its B10D reliability data is 4 000 000.

This emergency stop rope pull switch is suitable for woodworking machines, shears, conveyor systems, printing machines, textile machines, rolling mills, test laboratories, paint shops, surface treatment works, etc.

Its IP65 degree of protection makes it ideal for heavy duty use in harsh conditions.

It also complies with EN/IEC 60204-1, EN/IEC 60947-5-1, EN/IEC 60947-5-5, EN/ISO 13850, UL NISD, CSA C22.2 No 14-13 standards.

When associated and correctly connected to an appropriate safety control unit, it conforms to category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.

More Information
More Information
Attribute Value
SKU XY2CH13250
product certifications CCC, UL category NISD emergency stop devices
ambient air temperature for storage -40-70 °C
overvoltage category class I conforming to EN/IEC 61140, class I conforming to NF C 20-030
ambient air temperature for operation -25-70 °C
number of cables 1
reset by booted push-button
safety reliability data B10d = 4000000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear
terminals description ISO n°1 (13-14)NO, (21-22)NC
range of product Telemecanique Emergency stop rope pull switches XY2C
product or component type Detektor / Sensor
net weight 0.865 kg
standards EN/IEC 60947-5-1, EN/IEC 60204-1, EN/ISO 13850, EN/IEC 60947-5-5, work equipment directive 2009/104/EC, machinery directive 2006/42/EC
mechanical durability 800000 cycles
device short name XY2CH
range Limit Switch
[Ie] rated operational current 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A, 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
short-circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60269
contact operation slow-break
positive opening with conforming to EN/IEC 60947-5-1
connections - terminals screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
compatibility code XY2CH
marking CE
vibration resistance 10 gn (f= 10-150 Hz) conforming to EN/IEC 60068-2-6
IP degree of protection IP65 conforming to IEC 60529
tightening torque 0.8-1.2 N.m
local signalling without pilot light
[Ui] rated insulation voltage 300 V conforming to UL 508, 500 V (pollution degree 3) conforming to EN/IEC 60947-1
protective treatment TC
contacts type and composition 1 NC + 1 NO
shock resistance 50 gn 11 ms conforming to EN/IEC 60068-2-27
[Ithe] conventional enclosed thermal current 10 A
maximum resistance across terminals 25 mOhm conforming to NF C 93-050 method A, 25 MOhm conforming to EN/IEC 60255-7 category 3
body material zamak
cable entry number 3 tapped entry for Pg 13.5 cable gland
safety level can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1, can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1, can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
trigger cable maximum length 30 m
housing colour red RAL 3000
distance between cable supports 5-5 m
trigger cable anchor point RH or LH side
cover material stainless steel
PT. Telesindo Citra Sejahtera © 2025 All Rights Reserved.