Schneider Electric

Sepam series 20 8 temperature sensor module MET148-2 for Sepam series 20, 40, 60, 80 - 59641

Out of stock
SKU
59641
33%
Special Price Rp 6.928.570 Regular Price Rp 10.341.149
More Information
More Information
Attribute Value
SKU 59641
ambient air temperature for operation -25-70 °C
range of product Sepam series 80 NPP, Sepam series 80, Sepam series 20, Sepam series 60, Sepam series 40
product or component type Relay Proteksi Digital
net weight 0.2 kg
mounting mode fixed
device short name MET148-2
range Sepam Series 20
mechanical robustness earthquakes in operation (level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3, earthquakes in operation (level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3, jolts de-energized (level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2, shocks de-energized (level: 2) : 27 Gn/11 ms conforming to IEC 60255-21-2, shocks in operation (level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2, vibrations de-energized (level: 2) : 2 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1, vibrations in operation (level: 2) : 1 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1, vibrations in operation (level: Fc) : 2 Hz...13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6
auxiliary connection terminal earthing terminal: screw-type connectorscable <1000 m, earthing terminal: screw-type connectorstinned copper braid 6-100 mm² <1000 m, RTDs: screw-type connectors1 cable(s) wire 0.2-2.5 mm², RTDs: screw-type connectors2 cable(s) wire 0.2-1 mm²
electromagnetic compatibility fast transient bursts: (immunity tests-conducted disturbances), 4kV, 2.5 kHz, conforming to ANSI C37.90.1, fast transient bursts: (immunity tests-conducted disturbances), A and B, 4kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4, fast transient bursts: (immunity tests-conducted disturbances), IV, 4kV, 2.5 kHz, conforming to IEC 61000-4-4, immunity to conducted RF disturbances: (immunity tests-conducted disturbances), III, 10 V, conforming to IEC 60255-22-6, immunity to radiated fields: (immunity tests-radiated disturbances), 10 V/m, 80 MHz...1 GHz, conforming to IEC 60255-22-3, immunity to radiated fields: (immunity tests-radiated disturbances), 35 V/m, 25 MHz...1 GHz, conforming to ANSI C37.90.2, immunity to radiated fields: (immunity tests-radiated disturbances), III, 10 V/m, 80 MHz...2 GHz, conforming to IEC 61000-4-3, voltage interruptions: (immunity tests-conducted disturbances), 100 % during 100 ms, conforming to IEC 60255-11, conducted disturbance emission: (emission tests), conforming to IEC 60255-25, conducted disturbance emission: (emission tests), A, conforming to EN 55022, disturbing field emission: (emission tests), conforming to IEC 60255-25, disturbing field emission: (emission tests), A, conforming to EN 55022, electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 4 kV contact, conforming to ANSI C37.90.3, electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2, 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV DM, conforming to IEC 60255-22-1, immunity to magnetic fields at network frequency: (immunity tests-radiated disturbances), IV, 30 A/m (continuous)-300 A/m (1-3 s), conforming to IEC 61000-4-8, surges: (immunity tests-conducted disturbances), III, 2 kV CM, 1 kV DM, conforming to IEC 61000-4-5, 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 2.5 kV DM, conforming to ANSI C37.90.1, 100 kHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV DM, conforming to IEC 61000-4-12
type of measurement temperature
module type temperature sensor
height 88 mm
mounting support symmetrical DIN rail
width 144 mm
depth 30 mm
tightening torque earthing terminal: 2.2-2.2 N.m
number of inputs 8
climatic withstand influence of corrosion/gaz test 2 (in operation) : 21 days, 75 % RH, 25 °C, 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60, salt mist (in operation) : Kb/2: 6 days conforming to IEC 60068-2-52, temperature variation with specified variation rate (in storage) : Nb: - 25 °C to 70 °C, 5 °C/min conforming to IEC 60068-2-14, influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.2 ppm NO2, 0.01 ppm CI2 conforming to IEC 60068-2-60, continuous exposure to damp heat (in operation) : Cab: 10 days, 93 % RH, 40 °C conforming to IEC 60068-2-78, continuous exposure to damp heat (in storage) : Cab: 56 days, 93 % RH, 40 °C conforming to IEC 60068-2-78, continuous exposure to damp heat (in storage) : Db: 6 days, 95 % RH, 55 °C conforming to IEC 60068-2-30, exposure to cold (in storage) : Ab: - 25 °C conforming to IEC 60068-2-1, exposure to dry heat (in operation) : Bd: 70 °C conforming to IEC 60068-2-2, exposure to dry heat (in storage) : Bb: 70 °C conforming to IEC 60068-2-2, exposure to cold (in operation) : Ad: - 25 °C conforming to IEC 60068-2-1
maximum distance between sensor and module 1 km
temperature probe type Ni 100/Ni 120, <4 mA isolation from earth: none, Pt 100, <4 mA isolation from earth: none
PT. Telesindo Citra Sejahtera © 2025 All Rights Reserved.