Schneider Electric
Sepam series 20 analog output module MSA141 for Sepam series 20, 40, 60, 80 - 59647
Out of stock
SKU
59647
More Information
Attribute | Value |
---|---|
SKU | 59647 |
ambient air temperature for operation | -25-70 °C |
range of product | Sepam series 80 NPP, Sepam series 80, Sepam series 48, Sepam series 20, Sepam series 60, Sepam series 40 |
product or component type | Relay Proteksi Digital |
net weight | 0.2 kg |
mounting mode | fixed |
device short name | MSA141 |
range | Sepam Series 20 |
mechanical robustness | earthquakes in operation (level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3, earthquakes in operation (level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3, jolts de-energized (level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2, shocks de-energized (level: 2) : 27 Gn/11 ms conforming to IEC 60255-21-2, shocks in operation (level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2, vibrations de-energized (level: 2) : 2 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1, vibrations in operation (level: 2) : 1 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1, vibrations in operation (level: Fc) : 2 Hz...13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6 |
auxiliary connection terminal | analog output: screw-type connectors1 cable(s) wire 0.2-2.5 mm², analog output: screw-type connectors2 cable(s) wire 0.2-1 mm², earthing terminal: screw-type connectorscable 2.5-50 mm², earthing terminal: screw-type connectorstinned copper braid 6-100 mm² |
electromagnetic compatibility | fast transient bursts: (immunity tests-conducted disturbances), 4kV, 2.5 kHz, conforming to ANSI C37.90.1, fast transient bursts: (immunity tests-conducted disturbances), A and B, 4kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4, fast transient bursts: (immunity tests-conducted disturbances), IV, 4kV, 2.5 kHz, conforming to IEC 61000-4-4, immunity to conducted RF disturbances: (immunity tests-conducted disturbances), III, 10 V, conforming to IEC 60255-22-6, immunity to radiated fields: (immunity tests-radiated disturbances), 10 V/m, 80 MHz...1 GHz, conforming to IEC 60255-22-3, immunity to radiated fields: (immunity tests-radiated disturbances), 35 V/m, 25 MHz...1 GHz, conforming to ANSI C37.90.2, immunity to radiated fields: (immunity tests-radiated disturbances), III, 10 V/m, 80 MHz...2 GHz, conforming to IEC 61000-4-3, voltage interruptions: (immunity tests-conducted disturbances), 100 % during 100 ms, conforming to IEC 60255-11, conducted disturbance emission: (emission tests), conforming to IEC 60255-25, conducted disturbance emission: (emission tests), A, conforming to EN 55022, disturbing field emission: (emission tests), conforming to IEC 60255-25, disturbing field emission: (emission tests), A, conforming to EN 55022, electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 4 kV contact, conforming to ANSI C37.90.3, electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2, 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV DM, conforming to IEC 60255-22-1, immunity to magnetic fields at network frequency: (immunity tests-radiated disturbances), IV, 30 A/m (continuous)-300 A/m (1-3 s), conforming to IEC 61000-4-8, surges: (immunity tests-conducted disturbances), III, 2 kV CM, 1 kV DM, conforming to IEC 61000-4-5, 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 2.5 kV DM, conforming to ANSI C37.90.1, 100 kHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV DM, conforming to IEC 61000-4-12 |
type of measurement | apparent power ( 0.1 kVA ), thermal capacity used ( 1 % ), remote setting via communication link, temperature ( 1 °C ), active power ( 0.1 kW ), frequency ( 0.01 Hz ), phase and residual current ( 0.1 A ), phase-to-neutral and phase-to-phase voltages ( 1 V ), power factor ( 0,01 ), reactive power ( 0.1 kvar ) |
module type | analog output |
height | 88 mm |
mounting support | symmetrical DIN rail |
width | 144 mm |
depth | 30 mm |
tightening torque | earthing terminal: 2.2-2.2 N.m |
number of outputs | 1 analog |
climatic withstand | influence of corrosion/gaz test 2 (in operation) : 21 days, 75 % RH, 25 °C, 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60, salt mist (in operation) : Kb/2: 6 days conforming to IEC 60068-2-52, temperature variation with specified variation rate (in storage) : Nb: - 25 °C to 70 °C, 5 °C/min conforming to IEC 60068-2-14, influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.2 ppm NO2, 0.01 ppm CI2 conforming to IEC 60068-2-60, continuous exposure to damp heat (in operation) : Cab: 10 days, 93 % RH, 40 °C conforming to IEC 60068-2-78, continuous exposure to damp heat (in storage) : Cab: 56 days, 93 % RH, 40 °C conforming to IEC 60068-2-78, continuous exposure to damp heat (in storage) : Db: 6 days, 95 % RH, 55 °C conforming to IEC 60068-2-30, exposure to cold (in storage) : Ab: - 25 °C conforming to IEC 60068-2-1, exposure to dry heat (in operation) : Bd: 70 °C conforming to IEC 60068-2-2, exposure to dry heat (in storage) : Bb: 70 °C conforming to IEC 60068-2-2, exposure to cold (in operation) : Ad: - 25 °C conforming to IEC 60068-2-1 |
analogue output current | 0-10 mA load impedance: < 600 Ohm (including wiring) accuracy: 0.5 %, 0-20 mA load impedance: < 600 Ohm (including wiring) accuracy: 0.5 %, 4-20 mA load impedance: < 600 Ohm (including wiring) accuracy: 0.5 % |