Schneider Electric

Sepam series 20 RS485 multi-protocol interface ACE969TP-2 Sepam series 20, 40, 60, 80 - 59723

Out of stock
SKU
59723
33%
Special Price Rp 13.757.558 Regular Price Rp 20.533.668
More Information
More Information
Attribute Value
SKU 59723
ambient air temperature for operation -25-70 °C
range of product Sepam series 80 NPP, Sepam series 80, Sepam series 20, Sepam series 60, Sepam series 40
product or component type Relay Proteksi Digital
net weight 0.285 kg
mounting mode fixed
device short name ACE969TP-2
range Sepam Series 20
wire stripping length supply: 8 mm
mechanical robustness earthquakes in operation (level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3, earthquakes in operation (level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3, jolts de-energized (level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2, shocks in operation (level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2, vibrations de-energized (level: 2) : 2 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1, vibrations in operation (level: 2) : 1 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1, vibrations in operation (level: Fc) : 2 Hz...13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6, shocks de-energized (level: 2) : 30 Gn/11 ms conforming to IEC 60255-21-2
auxiliary connection terminal protective earth: screw-type connector 1 pin(s) 1 cable(s) wire 2.5-2.5 mm² <3 m, supply: screw-type connector 2 pin(s) 1 cable(s) wire 0.2-2.5 mm², supply: screw-type connector 2 pin(s) 1 cable(s) wire 1.5-1.5 mm², supply: screw-type connector 2 pin(s) 1 cable(s) wire 2.5-2.5 mm², supply: screw-type connector 2 pin(s) 2 cable(s) wire 0.2-1 mm², supply: screw-type connector 2 pin(s) 2 cable(s) wire 1-1 mm², functional earth: ring lug 1 pin(s) 1 cable(s)
electromagnetic compatibility fast transient bursts: (immunity tests-conducted disturbances), 4kV, 2.5 kHz, conforming to ANSI C37.90.1, fast transient bursts: (immunity tests-conducted disturbances), IV, 4kV, 2.5 kHz, conforming to IEC 61000-4-4, immunity to magnetic fields at network frequency: (immunity tests-radiated disturbances), IV, 30 A/m (continuous)-300 A/m (13 s), conforming to IEC 61000-4-8, immunity to radiated fields: (immunity tests-radiated disturbances), 10 V/m, 80 MHz...1 GHz, conforming to IEC 60255-22-3, immunity to radiated fields: (immunity tests-radiated disturbances), III, 10 V/m, 80 MHz...2 GHz, conforming to IEC 61000-4-3, conducted disturbance emission: (emission tests), conforming to IEC 60255-25, disturbing field emission: (emission tests), conforming to IEC 60255-25, disturbing field emission: (emission tests), A, conforming to EN 55022, electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 4 kV contact, conforming to ANSI C37.90.3, electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2, 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV MC and MD, conforming to ANSI C37.90.1, fast transient bursts: (immunity tests-conducted disturbances), A or B, 4kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4, immunity to conducted RF disturbances: (immunity tests-conducted disturbances), 10 V, conforming to IEC 60255-22-6, immunity to radiated fields: (immunity tests-radiated disturbances), 35 V/m, 25 MHz...1 GHz, conforming to ANSI C37.90.2 (1995), surges: (immunity tests-conducted disturbances), III, 2 kV MC, 1 kV MD, conforming to IEC 61000-4-5, voltage interruptions: (immunity tests-conducted disturbances), 100 %, 10 ms, conforming to IEC 60255-11, 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), III, 2.5 kV MC, 1 kV MD, conforming to IEC 60255-22-1, 100 kHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV MC, 1 kV MD, conforming to IEC 61000-4-12, conducted disturbance emission: (emission tests), B, conforming to EN 55022
maximum cable distance between devices 10 Devices <180 m at 12 V DC, 10 Devices <750 m at 24 V DC, 20 Devices <160 m at 12 V DC, 20 Devices <450 m at 24 V DC, 25 Devices <125 m at 12 V DC, 25 Devices <375 m at 24 V DC, 5 Devices <1000 m at 24 V DC, 5 Devices <320 m at 12 V DC
height 90 mm
mounting support symmetrical DIN rail
width 144 mm
depth 52 mm
local signalling green LED for energized (front face), LED for receiving data (front face), LED for sending data (front face), red LED flashing for not set up or set up incorrect (front face), red LED off for set up and communication operational (front face), red LED remains ON for fault (front face)
communication port protocol DNP3 network: S-LAN interface: RS485 - 2-wire, IEC 60870-5-103 network: S-LAN interface: RS485 - 2-wire, Modbus RTU network: E-LAN interface: RS485 - 2-wire, Modbus RTU network: S-LAN interface: RS485 - 2-wire
climatic withstand influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.02 ppm NO2, 0.01 ppm Cl2 conforming to IEC 60068-2-60, temperature variation with specified variation rate (in operation) : Nb: - 25 °C to 70 °C (- 13 °F to 158 °F) 5 °C/min (41 °F/min) conforming to IEC 60068-2-14, continuous exposure to damp heat (in operation) : Ca: 10 days, 93 % RH, 40 °C (104 °F) conforming to IEC 60068-2-3, continuous exposure to damp heat (in storage) : Ca: 56 days, 93 % RH, 40 °C (104 °F) conforming to IEC 60068-2-3, exposure to cold (in operation) : Ab: - 25 °C (- 13 °F) conforming to IEC 60068-2-1, exposure to cold (in storage) : Ab: - 25 °C (- 13 °F) conforming to IEC 60068-2-1, exposure to dry heat (in operation) : Bb: 70 °C (158 °F) conforming to IEC 60068-2-2, exposure to dry heat (in storage) : Bb: 70 °C (158 °F) conforming to IEC 60068-2-2, influence of corrosion/gaz test 2 (in operation) : C: 21 days, 75 % RH, 25 °C (- 13 °F), 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60, salt mist (in operation) : Kb/2 conforming to IEC 60068-2-52