Schneider Electric
Sepam series 80 synchro-check module MCS025 Sepam series 60, 80 - 59712
Out of stock
SKU
59712
More Information
Attribute | Value |
---|---|
SKU | 59712 |
product certifications | CE, UL 508 file N° 212533, C22.2 file N° 210625 |
range of product | Sepam series 80 NPP, Sepam series 80, Sepam series 60 |
product or component type | Relay Proteksi Digital |
net weight | 1.35 kg |
mounting mode | fixed |
standards | UL 508, EN 50263, CSA C22.2 No 14-95, CSA C22.2 No 0.17-00, CSA C22.2 No 94-M91 |
device short name | MCS025 |
range | Sepam Series 80 |
[Uimp] rated impulse withstand voltage | 5 kV (1.2/50 µs) conforming to IEC 60255-5 |
mechanical robustness | earthquakes in operation (level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3, earthquakes in operation (level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3, jolts de-energized (level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2, shocks de-energized (level: 2) : 27 Gn/11 ms conforming to IEC 60255-21-2, shocks in operation (level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2, vibrations de-energized (level: 2) : 2 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1, vibrations in operation (level: 2) : 1 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1, vibrations in operation (level: Fc) : 2 Hz...13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6 |
[Us] rated supply voltage | 10...240 V AC 47.5...63 Hz tolerance: - 20 %...+ 0 % deactivated consumption: 9 VA, 24...250 V DC tolerance: - 10...10 % deactivated consumption: 6 W |
electromagnetic compatibility | 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV MD, conforming to IEC 60255-22-1, fast transient bursts: (immunity tests-conducted disturbances), 4kV, 2.5 kHz, conforming to ANSI C37.90.1, fast transient bursts: (immunity tests-conducted disturbances), A and B, 4kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4, fast transient bursts: (immunity tests-conducted disturbances), IV, 4kV, 2.5 kHz, conforming to IEC 61000-4-4, immunity to conducted RF disturbances: (immunity tests-conducted disturbances), III, 10 V, conforming to IEC 60255-22-6, immunity to magnetic fields at network frequency: (immunity tests-radiated disturbances), IV, 30 A/m (continuous)-300 A/m (13 s), conforming to IEC 61000-4-8, immunity to radiated fields: (immunity tests-radiated disturbances), 10 V/m, 80 MHz...1 GHz, conforming to IEC 60255-22-3, immunity to radiated fields: (immunity tests-radiated disturbances), 35 V/m, 25 MHz...1 GHz, conforming to ANSI C37.90.2, immunity to radiated fields: (immunity tests-radiated disturbances), III, 10 V/m, 80 MHz...2 GHz, conforming to IEC 61000-4-3, surges: (immunity tests-conducted disturbances), III, 2 kV CM, 1 kV MD, conforming to IEC 61000-4-5, voltage interruptions: (immunity tests-conducted disturbances), 100 % during 100 ms, conforming to IEC 60255-11, 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 2.5 kV MD, conforming to ANSI C37.90.1, 100 kHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV MD, conforming to IEC 61000-4-12, conducted disturbance emission: (emission tests), conforming to IEC 60255-25, conducted disturbance emission: (emission tests), A, conforming to EN 55022, disturbing field emission: (emission tests), conforming to IEC 60255-25, disturbing field emission: (emission tests), A, conforming to EN 55022, electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 4 kV contact, conforming to ANSI C37.90.3, electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2 |
immunity to microbreaks | 100 ms |
output type | relay: 100...240 V AC 47.5...63 Hz continuous current: 2 A breaking capacity: 5 A cos φ > 0.3, relay: 220 V DC continuous current: 8 A breaking capacity: 0.2 A L/R < 20 ms making capacity: < 15 A for 200 ms, relay: 220 V DC continuous current: 8 A breaking capacity: 0.3 A resistive making capacity: < 15 A for 200 ms, relay: 24 V DC continuous current: 2 A breaking capacity: 2 A L/R < 20 ms, relay: 24 V DC continuous current: 8 A breaking capacity: 4 A L/R < 40 ms making capacity: < 15 A for 200 ms, relay: 24 V DC continuous current: 8 A breaking capacity: 6 A L/R < 20 ms making capacity: < 15 A for 200 ms, relay: 24 V DC continuous current: 8 A breaking capacity: 8 A resistive making capacity: < 15 A for 200 ms, relay: 48 V DC continuous current: 2 A breaking capacity: 1 A L/R < 20 ms, relay: 48 V DC continuous current: 8 A breaking capacity: 1 A L/R < 40 ms making capacity: < 15 A for 200 ms, relay: 48 V DC continuous current: 8 A breaking capacity: 2 A L/R < 20 ms making capacity: < 15 A for 200 ms, relay: 48 V DC continuous current: 8 A breaking capacity: 4 A resistive making capacity: < 15 A for 200 ms, relay: 100...240 V AC 47.5...63 Hz continuous current: 8 A breaking capacity: 5 A cos φ > 0.3 making capacity: < 15 A for 200 ms, relay: 100...240 V AC 47.5...63 Hz continuous current: 8 A breaking capacity: 8 A resistive making capacity: < 15 A for 200 ms, relay: 127 V DC continuous current: 2 A breaking capacity: 0.5 A L/R < 20 ms, relay: 127 V DC continuous current: 8 A breaking capacity: 0.2 A L/R < 40 ms making capacity: < 15 A for 200 ms, relay: 127 V DC continuous current: 8 A breaking capacity: 0.5 A L/R < 20 ms making capacity: < 15 A for 200 ms, relay: 127 V DC continuous current: 8 A breaking capacity: 0.7 A resistive making capacity: < 15 A for 200 ms, relay: 220 V DC continuous current: 2 A breaking capacity: 0.15 A L/R < 20 ms, relay: 220 V DC continuous current: 8 A breaking capacity: 0.1 A L/R < 40 ms making capacity: < 15 A for 200 ms |
height | 222 mm |
mounting support | mounting plate |
width | 176 mm |
depth | 121 mm |
IP degree of protection | other panels: IP20 conforming to IEC 60529, front panel: IP52 conforming to IEC 60529 |
fire resistance | 650 °C conforming to IEC 60695-2-11 |
NEMA degree of protection | Type 12 conforming to NEMA |
number of outputs | 3 relay |
supply inrush current | < 10 A for 10 ms at 24...250 V DC, < 15 A at 110...240 V AC |
climatic withstand | influence of corrosion/gaz test 2 (in operation) : 21 days, 75 % RH, 25 °C, 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60, salt mist (in operation) : Kb/2: 6 days conforming to IEC 60068-2-52, temperature variation with specified variation rate (in storage) : Nb: - 25 °C to 70 °C, 5 °C/min conforming to IEC 60068-2-14, influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.2 ppm NO2, 0.01 ppm CI2 conforming to IEC 60068-2-60, continuous exposure to damp heat (in operation) : Cab: 10 days, 93 % RH, 40 °C conforming to IEC 60068-2-78, continuous exposure to damp heat (in storage) : Cab: 56 days, 93 % RH, 40 °C conforming to IEC 60068-2-78, continuous exposure to damp heat (in storage) : Db: 6 days, 95 % RH, 55 °C conforming to IEC 60068-2-30, exposure to cold: Ad: - 25 °C conforming to IEC 60068-2-1, exposure to cold (in storage) : Ab: - 25 °C conforming to IEC 60068-2-1, exposure to dry heat (in operation) : Bd: 70 °C conforming to IEC 60068-2-2, exposure to dry heat (in storage) : Bb: 70 °C conforming to IEC 60068-2-2 |
power frequency dielectric withstand | 1 kV (indication output) during 1 min conforming to ANSI C37.90, 1.5 kV (control output) during 1 min conforming to ANSI C37.90, 2 kV during 1 min conforming to IEC 60255-5 |