Schneider Electric

Sepam series 80 synchro-check module MCS025 Sepam series 60, 80 - 59712

Out of stock
SKU
59712
33%
Special Price Rp 21.984.516 Regular Price Rp 32.812.710
More Information
More Information
Attribute Value
SKU 59712
product certifications CE, UL 508 file N° 212533, C22.2 file N° 210625
range of product Sepam series 80 NPP, Sepam series 80, Sepam series 60
product or component type Relay Proteksi Digital
net weight 1.35 kg
mounting mode fixed
standards UL 508, EN 50263, CSA C22.2 No 14-95, CSA C22.2 No 0.17-00, CSA C22.2 No 94-M91
device short name MCS025
range Sepam Series 80
[Uimp] rated impulse withstand voltage 5 kV (1.2/50 µs) conforming to IEC 60255-5
mechanical robustness earthquakes in operation (level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3, earthquakes in operation (level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3, jolts de-energized (level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2, shocks de-energized (level: 2) : 27 Gn/11 ms conforming to IEC 60255-21-2, shocks in operation (level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2, vibrations de-energized (level: 2) : 2 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1, vibrations in operation (level: 2) : 1 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1, vibrations in operation (level: Fc) : 2 Hz...13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6
[Us] rated supply voltage 10...240 V AC 47.5...63 Hz tolerance: - 20 %...+ 0 % deactivated consumption: 9 VA, 24...250 V DC tolerance: - 10...10 % deactivated consumption: 6 W
electromagnetic compatibility 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV MD, conforming to IEC 60255-22-1, fast transient bursts: (immunity tests-conducted disturbances), 4kV, 2.5 kHz, conforming to ANSI C37.90.1, fast transient bursts: (immunity tests-conducted disturbances), A and B, 4kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4, fast transient bursts: (immunity tests-conducted disturbances), IV, 4kV, 2.5 kHz, conforming to IEC 61000-4-4, immunity to conducted RF disturbances: (immunity tests-conducted disturbances), III, 10 V, conforming to IEC 60255-22-6, immunity to magnetic fields at network frequency: (immunity tests-radiated disturbances), IV, 30 A/m (continuous)-300 A/m (13 s), conforming to IEC 61000-4-8, immunity to radiated fields: (immunity tests-radiated disturbances), 10 V/m, 80 MHz...1 GHz, conforming to IEC 60255-22-3, immunity to radiated fields: (immunity tests-radiated disturbances), 35 V/m, 25 MHz...1 GHz, conforming to ANSI C37.90.2, immunity to radiated fields: (immunity tests-radiated disturbances), III, 10 V/m, 80 MHz...2 GHz, conforming to IEC 61000-4-3, surges: (immunity tests-conducted disturbances), III, 2 kV CM, 1 kV MD, conforming to IEC 61000-4-5, voltage interruptions: (immunity tests-conducted disturbances), 100 % during 100 ms, conforming to IEC 60255-11, 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 2.5 kV MD, conforming to ANSI C37.90.1, 100 kHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV MD, conforming to IEC 61000-4-12, conducted disturbance emission: (emission tests), conforming to IEC 60255-25, conducted disturbance emission: (emission tests), A, conforming to EN 55022, disturbing field emission: (emission tests), conforming to IEC 60255-25, disturbing field emission: (emission tests), A, conforming to EN 55022, electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 4 kV contact, conforming to ANSI C37.90.3, electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2
immunity to microbreaks 100 ms
output type relay: 100...240 V AC 47.5...63 Hz continuous current: 2 A breaking capacity: 5 A cos φ > 0.3, relay: 220 V DC continuous current: 8 A breaking capacity: 0.2 A L/R < 20 ms making capacity: < 15 A for 200 ms, relay: 220 V DC continuous current: 8 A breaking capacity: 0.3 A resistive making capacity: < 15 A for 200 ms, relay: 24 V DC continuous current: 2 A breaking capacity: 2 A L/R < 20 ms, relay: 24 V DC continuous current: 8 A breaking capacity: 4 A L/R < 40 ms making capacity: < 15 A for 200 ms, relay: 24 V DC continuous current: 8 A breaking capacity: 6 A L/R < 20 ms making capacity: < 15 A for 200 ms, relay: 24 V DC continuous current: 8 A breaking capacity: 8 A resistive making capacity: < 15 A for 200 ms, relay: 48 V DC continuous current: 2 A breaking capacity: 1 A L/R < 20 ms, relay: 48 V DC continuous current: 8 A breaking capacity: 1 A L/R < 40 ms making capacity: < 15 A for 200 ms, relay: 48 V DC continuous current: 8 A breaking capacity: 2 A L/R < 20 ms making capacity: < 15 A for 200 ms, relay: 48 V DC continuous current: 8 A breaking capacity: 4 A resistive making capacity: < 15 A for 200 ms, relay: 100...240 V AC 47.5...63 Hz continuous current: 8 A breaking capacity: 5 A cos φ > 0.3 making capacity: < 15 A for 200 ms, relay: 100...240 V AC 47.5...63 Hz continuous current: 8 A breaking capacity: 8 A resistive making capacity: < 15 A for 200 ms, relay: 127 V DC continuous current: 2 A breaking capacity: 0.5 A L/R < 20 ms, relay: 127 V DC continuous current: 8 A breaking capacity: 0.2 A L/R < 40 ms making capacity: < 15 A for 200 ms, relay: 127 V DC continuous current: 8 A breaking capacity: 0.5 A L/R < 20 ms making capacity: < 15 A for 200 ms, relay: 127 V DC continuous current: 8 A breaking capacity: 0.7 A resistive making capacity: < 15 A for 200 ms, relay: 220 V DC continuous current: 2 A breaking capacity: 0.15 A L/R < 20 ms, relay: 220 V DC continuous current: 8 A breaking capacity: 0.1 A L/R < 40 ms making capacity: < 15 A for 200 ms
height 222 mm
mounting support mounting plate
width 176 mm
depth 121 mm
IP degree of protection other panels: IP20 conforming to IEC 60529, front panel: IP52 conforming to IEC 60529
fire resistance 650 °C conforming to IEC 60695-2-11
NEMA degree of protection Type 12 conforming to NEMA
number of outputs 3 relay
supply inrush current < 10 A for 10 ms at 24...250 V DC, < 15 A at 110...240 V AC
climatic withstand influence of corrosion/gaz test 2 (in operation) : 21 days, 75 % RH, 25 °C, 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60, salt mist (in operation) : Kb/2: 6 days conforming to IEC 60068-2-52, temperature variation with specified variation rate (in storage) : Nb: - 25 °C to 70 °C, 5 °C/min conforming to IEC 60068-2-14, influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.2 ppm NO2, 0.01 ppm CI2 conforming to IEC 60068-2-60, continuous exposure to damp heat (in operation) : Cab: 10 days, 93 % RH, 40 °C conforming to IEC 60068-2-78, continuous exposure to damp heat (in storage) : Cab: 56 days, 93 % RH, 40 °C conforming to IEC 60068-2-78, continuous exposure to damp heat (in storage) : Db: 6 days, 95 % RH, 55 °C conforming to IEC 60068-2-30, exposure to cold: Ad: - 25 °C conforming to IEC 60068-2-1, exposure to cold (in storage) : Ab: - 25 °C conforming to IEC 60068-2-1, exposure to dry heat (in operation) : Bd: 70 °C conforming to IEC 60068-2-2, exposure to dry heat (in storage) : Bb: 70 °C conforming to IEC 60068-2-2
power frequency dielectric withstand 1 kV (indication output) during 1 min conforming to ANSI C37.90, 1.5 kV (control output) during 1 min conforming to ANSI C37.90, 2 kV during 1 min conforming to IEC 60255-5