Schneider Electric

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 95 A - 220 V AC 50/60 Hz coil - LC1D95M7

In stock
SKU
LC1D95M7
38%
Special Price Rp 2.727.337 Regular Price Rp 4.398.930
Details

TeSys D contactor, 3 poles (3NO), for motor control applications up to 95A/1000V AC-3 (45kW@400V).

It provides a 220V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts, power connections by screw terminals and control by screw clamp terminals.

For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability.

Compact (85mm width), DIN-rail mounting or screw fixing.

Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

More Information
More Information
Attribute Value
SKU LC1D95M7
product certifications EAC, CCC, LROS (Lloyds register of shipping), BV, RINA, CSA, UL, IECEE CB Scheme, DNV-GL
ambient air temperature for storage -60-80 °C
overvoltage category III
pollution degree 3
ambient air temperature for operation -40-60 °C, 60-70 °C with derating
non-overlap time 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
motor power hp 7.5 hp at 115 V AC 60 Hz for 1 phase motors, 15 hp at 230/240 V AC 60 Hz for 1 phase motors, 25 hp at 200/208 V AC 60 Hz for 3 phases motors, 30 hp at 230/240 V AC 60 Hz for 3 phases motors, 60 hp at 460/480 V AC 60 Hz for 3 phases motors, 60 hp at 575/600 V AC 60 Hz for 3 phases motors
[Icw] rated short-time withstand current 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 800 A 40 °C - 10 s for power circuit, 1100 A 40 °C - 1 s for power circuit, 135 A 40 °C - 10 min for power circuit, 400 A 40 °C - 1 min for power circuit
range of product TeSys D
product or component type Kontaktor
net weight 1.61 kg
standards EN/IEC 60947-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, EN/IEC 60947-4-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.4
mechanical durability 4 Mcycles
device short name LC1D
range TeSys D
average impedance 0.8 mOhm - Ith 125 A 50 Hz for power circuit
[Ie] rated operational current 95 A (at <60 °C) at <= 440 V AC-3 for power circuit, 125 A (at <60 °C) at <= 690 V AC-1 for power circuit
[Uc] control circuit voltage 220 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
product name TeSys D
minimum switching current 5 mA for signalling circuit
mechanical robustness vibrations contactor open: 2 Gn, 5...300 Hz, shocks contactor open: 8 Gn for 11 ms, vibrations contactor closed: 3 Gn, 5...300 Hz, shocks contactor closed: 10 Gn for 11 ms
power dissipation per pole 7.2 W AC-3, 12.5 W AC-1
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit, 125 A (at 60 °C) for power circuit
control circuit type AC at 50/60 Hz
safety reliability level B10d = 1.3 Mcycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20 Mcycles contactor with mechanical load conforming to EN/ISO 13849-1
contactor application motor control, resistive load
contactor coil voltage 220 V AC standard
insulation resistance > 10 MOhm for signalling circuit
rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 1100 A at 440 V AC for power circuit conforming to IEC 60947
power range 15-25 kW at 200-240 V 3 phases, 30-50 kW at 380-440 V 3 phases, 30-50 kW at 480-500 V 3 phases, 55-100 kW at 480-500 V 3 phases
pole contact composition 3 NO
motor starter type direct on-line contactor
auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1
operating time 6...20 ms opening, 20...35 ms closing
protective cover with
hold-in power consumption in VA 26-26 VA 60 Hz cos phi 0.3 (at 20 °C), 26-26 VA 50 Hz cos phi 0.3 (at 20 °C)
inrush power in VA 245-245 VA 60 Hz cos phi 0.75 (at 20 °C), 245-245 VA 50 Hz cos phi 0.75 (at 20 °C)
connections - terminals control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end, control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end, control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end, control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end, control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end, control circuit: screw clamp terminals 1 cable(s) 1-2.5 mm²flexible with cable end, power circuit: connector 1 cable(s) 4-50 mm²flexible without cable end, power circuit: connector 2 cable(s) 4-25 mm²flexible without cable end, power circuit: connector 1 cable(s) 4-50 mm²flexible with cable end, power circuit: connector 2 cable(s) 4-16 mm²flexible with cable end, power circuit: connector 1 cable(s) 4-50 mm²solid without cable end, power circuit: connector 2 cable(s) 4-25 mm²solid without cable end
height 127 mm
mounting support plate, rail
compatibility code LC1D
width 85 mm
depth 130 mm
operating altitude 0...3000 m
IP degree of protection IP20 front face conforming to IEC 60529
poles description 3P
tightening torque control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2, power circuit: 12 N.m - on connector hexagonal screw head 4 mm, power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm
electrical durability 1.2 Mcycles 95 A AC-3, 1.3 Mcycles 125 A AC-1
[Ue] rated operational voltage power circuit: 1000 V AC 25...400 Hz
utilisation category AC-4, AC-3, AC-1
[Ui] rated insulation voltage power circuit: 600 V CSA certified, power circuit: 600 V UL certified, signalling circuit: 690 V conforming to IEC 60947-1, signalling circuit: 600 V CSA certified, signalling circuit: 600 V UL certified, power circuit: 1000 V conforming to IEC 60947-4-1
auxiliary contact composition 1 NO + 1 NC
control circuit voltage limits 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.85...1.1 Uc (-40-55 °C):operational AC 60 Hz, 0.8...1.1 Uc (-40-55 °C):operational AC 50 Hz, 1...1.1 Uc (55-70 °C):operational AC 50/60 Hz
contact compatibility M11
associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1, 200 A gG at <= 690 V coordination type 1 for power circuit, 160 A gG at <= 690 V coordination type 2 for power circuit
coil technology without built-in suppressor module
flame retardance V1 conforming to UL 94
minimum switching voltage 17 V for signalling circuit
maximum operating rate 3600 cyc/h 60 °C
signalling circuit frequency 25...400 Hz
protective treatment TH conforming to IEC 60068-2-30
fire resistance 850 °C conforming to IEC 60695-2-1
motor power kW 25 kW at 220...230 V AC 50 Hz (AC-3), 45 kW at 380...400 V AC 50 Hz (AC-3), 45 kW at 415...440 V AC 50 Hz (AC-3), 55 kW at 500 V AC 50 Hz (AC-3), 45 kW at 660...690 V AC 50 Hz (AC-3), 45 kW at 1000 V AC 50 Hz (AC-3)
heat dissipation 6-10 W at 50/60 Hz