Schneider Electric
TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 <= 440 V 80 A 220 V AC 50/60 Hz coil - LC1D65008M7
Out of stock
SKU
LC1D65008M7
More Information
| Attribute | Value |
|---|---|
| SKU | LC1D65008M7 |
| product certifications | CCC, LROS (Lloyds register of shipping), BV, GL, RINA, GOST, CSA, DNV, UL |
| ambient air temperature for storage | -60-80 °C |
| overvoltage category | III |
| pollution degree | 3 |
| ambient air temperature for operation | -40-60 °C, 60-70 °C with derating |
| [Icw] rated short-time withstand current | 520 A 40 °C - 10 s for power circuit, 900 A 40 °C - 1 s for power circuit, 110 A 40 °C - 10 min for power circuit, 260 A 40 °C - 1 min for power circuit |
| range of product | TeSys D |
| product or component type | Kontaktor |
| net weight | 1.45 kg |
| standards | CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 |
| mechanical durability | 6 Mcycles |
| device short name | LC1D |
| range | TeSys D |
| average impedance | 1.5 mOhm - Ith 80 A 50 Hz for power circuit |
| [Ie] rated operational current | 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
| [Uc] control circuit voltage | 220 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| product name | TeSys D |
| mechanical robustness | vibrations contactor open: 2 Gn, 5...300 Hz, vibrations contactor closed: 4 Gn, 5...300 Hz, shocks contactor closed: 15 Gn for 11 ms, shocks contactor open: 10 Gn for 11 ms |
| power dissipation per pole | 9.6 W AC-1 |
| [Ith] conventional free air thermal current | 80 A (at 60 °C) for power circuit |
| control circuit type | AC at 50/60 Hz |
| safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| contactor application | resistive load |
| rated breaking capacity | 1000 A at 440 V for power circuit conforming to IEC 60947 |
| Irms rated making capacity | 1000 A at 440 V for power circuit conforming to IEC 60947 |
| pole contact composition | 2 NO + 2 NC |
| operating time | 4...19 ms opening, 12...26 ms closing |
| protective cover | without |
| hold-in power consumption in VA | 13-13 VA 60 Hz cos phi 0.3 (at 20 °C), 15-15 VA 50 Hz cos phi 0.3 (at 20 °C) |
| inrush power in VA | 140-140 VA 60 Hz cos phi 0.75 (at 20 °C), 160-160 VA 50 Hz cos phi 0.75 (at 20 °C) |
| connections - terminals | control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end, control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end, control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end, control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end, control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end, control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end, power circuit: screw clamp terminals 1 cable(s) 1-35 mm²flexible without cable end, power circuit: screw clamp terminals 2 cable(s) 1-25 mm²flexible without cable end, power circuit: screw clamp terminals 1 cable(s) 1-35 mm²flexible with cable end, power circuit: screw clamp terminals 2 cable(s) 1-25 mm²flexible with cable end, power circuit: screw clamp terminals 1 cable(s) 1-35 mm²solid without cable end, power circuit: screw clamp terminals 2 cable(s) 1-25 mm²solid without cable end |
| height | 127 mm |
| mounting support | plate, rail |
| compatibility code | LC1D |
| width | 85 mm |
| depth | 125 mm |
| operating altitude | 0...3000 m |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| poles description | 4P |
| tightening torque | control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2, power circuit: 8 N.m - on screw clamp terminals - cable 25-35 mm² hexagonal screw head 4 mm, power circuit: 5 N.m - on screw clamp terminals - cable 1-25 mm² hexagonal screw head 4 mm |
| electrical durability | 1.4 Mcycles 80 A AC-1 at Ue <= 440 V |
| [Ue] rated operational voltage | power circuit: <= 690 V AC 25...400 Hz, power circuit: <= 300 V DC |
| utilisation category | AC-1 |
| [Ui] rated insulation voltage | power circuit: 690 V conforming to IEC 60947-4-1, power circuit: 600 V CSA certified, power circuit: 600 V UL certified |
| control circuit voltage limits | 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz |
| contact compatibility | M1 |
| associated fuse rating | 125 A gG at <= 690 V coordination type 1 for power circuit, 125 A gG at <= 690 V coordination type 2 for power circuit |
| coil technology | without built-in suppressor module |
| flame retardance | V1 conforming to UL 94 |
| maximum operating rate | 3600 cyc/h 60 °C |
| protective treatment | TH conforming to IEC 60068-2-30 |
| fire resistance | 850 °C conforming to IEC 60695-2-1 |
| heat dissipation | 4-5 W at 50/60 Hz |
Technical Documents