TeSys F contactor, 3 poles (3NO), 400A/1000V AC-3, for motor applications up to 200kW@400V.

Contactor with no coil to allow a later selection and installation (coil to be ordered separately), it provides bolt terminals for bars or cables with lugs.

For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability.

It makes installation and maintenance easy thanks to a drawer for insertion of the selected coil and a large choice of add-on blocks and accessories (to be ordered separately).

Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

More Information
More Information
Attribute Value
SKU LC1F400
product certifications LROS (Lloyds register of shipping), BV, RINA, CSA, DNV, UL, ABS, CB, RMRoS
ambient air temperature for storage -60-80 °C
overvoltage category III
ambient air temperature for operation -5-55 °C
[Icw] rated short-time withstand current 3600 A 40 °C - 10 s, 2400 A 40 °C - 30 s, 1700 A 40 °C - 1 min, 1200 A 40 °C - 3 min, 1000 A 40 °C - 10 min
range of product TeSys F
product or component type Kontaktor
net weight 8 kg
standards EN 60947-4-1, IEC 60947-4-1, IEC 60947-1, JIS C8201-4-1, EN 60947-1
mechanical durability 10 Mcycles
device short name LC1F
range TeSys F
average impedance 0.26 mOhm - Ith 500 A 50 Hz
[Ie] rated operational current 500 A (at <40 °C) at <= 440 V AC AC-1, 400 A (at <55 °C) at <= 440 V AC AC-3
[Uc] control circuit voltage 48...1000 V AC 40...400 Hz with LX1/LX9 coil, 48...440 V DC with LX4 coil, 100...250 V AC 50/60 Hz with LXE coil, 100...380 V DC with LXE coil
[Uimp] rated impulse withstand voltage 8 kV
product name TeSys F
mechanical robustness vibrations contactor open: 1.5 Gn, 5...300 Hz, vibrations contactor closed: 5 Gn, 5...300 Hz, shocks contactor open: 6 Gn for 1/2 sine wave (11 ms), shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
power dissipation per pole 42 W AC-3, 65 W AC-1
[Ith] conventional free air thermal current 500 A (at 40 °C)
contactor application motor control, resistive load
rated breaking capacity 3200 A conforming to IEC 60947-4-1
Irms rated making capacity 4000 A AC conforming to IEC 60947-4-1
pole contact composition 3 NO
operating time 100...170 ms opening for with LX1/LX9 coil, 40...80 ms closing for with LXE coil, 6...54 ms opening for with LXE coil, 40...75 ms closing for with LX1/LX9 coil, 50...60 ms closing for with LX4 coil, 45...60 ms opening for with LX4 coil
hold-in power consumption in VA 4.5-7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil, 2.5-4.0 VA (at 20 °C)with LXE coil, 12-18 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil, 4-7.5 VA (at 20 °C)with LX4 coil
inrush power in VA 1000-1150 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil, 920-1140 VA (at 20 °C)with LX4 coil, 360-470 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil, 410-450 VA (at 20 °C)with LXE coil
permissible ambient air temperature around the device -40-70 °C
connections - terminals control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end, control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end, control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²solid without cable end, control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible with cable end, control circuit: screw clamp terminals 1 cable(s) 1-4 mm², control circuit: screw clamp terminals 2 cable(s) 1-4 mm², control circuit: screw clamp terminals 1.0 cable(s) 0.2-2.5 mm²flexible without cable end, control circuit: screw clamp terminals 1.0 cable(s) 0.25-2.5 mm²flexible with cable end, control circuit: screw clamp terminals 1.0 cable(s) 0.2-2.5 mm²solid without cable end, power circuit: bar 2 cable(s) - busbar cross section: 30 x 5 mm, power circuit: lugs-ring terminals 2 cable(s) 150-150 mm²
height 206 mm
mounting support plate
compatibility code LC1F
width 213 mm
depth 219 mm
IP degree of protection IP20 front face with shrouds conforming to IEC 60529, IP20 front face with shrouds conforming to VDE 0106
poles description 3P
tightening torque control circuit: 1.2 N.m, power circuit: 35 N.m, control circuit: 0.6 N.m
[Ue] rated operational voltage <= 1000 V AC 50/60 Hz, <= 460 V DC
utilisation category AC-4, AC-3, AC-1
[Ui] rated insulation voltage 1000 V conforming to IEC 60947-4-1, 1500 V conforming to VDE 0110 group C
control circuit voltage limits operational: 0.85...1.1 Uc N/A 40...400 Hz with LX1/LX9 coil, operational: 0.85...1.1 Uc N/A with LX4 coil, drop-out: 0.2...0.35 Uc N/A with LX4 coil, operational: 85...275 V N/A 50/60 Hz with LXE coil, drop-out: 0...60 V N/A 50/60 Hz with LXE coil, operational: 85...418 V N/A with LXE coil, drop-out: 0...45 V N/A with LXE coil, drop-out: 0.3...0.5 Uc N/A 40...400 Hz with LX1/LX9 coil
associated fuse rating 400 A aM at <= 440 V, 500 A gG at <= 440 V
maximum operating rate 2400 cyc/h 55 °C
protective treatment TH
motor power kW 185 kW at 1000 V AC 50/60 Hz (AC-3), 200 kW at 380...400 V AC 50/60 Hz (AC-3), 220 kW at 415 V AC 50/60 Hz (AC-3), 250 kW at 440 V AC 50/60 Hz (AC-3), 257 kW at 500 V AC 50/60 Hz (AC-3), 110 kW at 220...240 V AC 50/60 Hz (AC-3), 280 kW at 660...690 V AC 50/60 Hz (AC-3), 75 kW at 400 V AC 50/60 Hz (AC-4)
heat dissipation 2.2-5.5 W, 14-14 W