TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 800 A - without coil - LC1F800
            Out of stock
        
    
            SKU
        
LC1F800
                        Details
                    
                    
TeSys F contactor, 3 poles (3NO), 800A/1000V AC-3, for motor applications up to 450kW@400V.
Contactor with no coil to allow a later selection and installation (coil to be ordered separately), it provides bolt terminals for bars or cables with lugs.
For high operating rates until 600 cycles/hour and environments until 55°C, it procures high reliability and durability.
It makes installation and maintenance easy thanks to a drawer for insertion of the selected coil and a large choice of add-on blocks and accessories (to be ordered separately).
Multi standards certified (IEC, UL, CSA, CCC, Marine), Green Premium compliant (RoHS/REACh).
                        More Information
                    
                        | Attribute | Value | 
|---|---|
| SKU | LC1F800 | 
| product certifications | CCC, LROS (Lloyds register of shipping), CSA, UL, ABS, CB | 
| ambient air temperature for storage | -60-80 °C | 
| overvoltage category | III | 
| ambient air temperature for operation | -5-55 °C | 
| [Icw] rated short-time withstand current | 2600 A 40 °C - 3 min, 5500 A 40 °C - 10 s, 4600 A 40 °C - 30 s, 3600 A 40 °C - 1 min, 1700 A 40 °C - 10 min | 
| range of product | TeSys F | 
| product or component type | Kontaktor | 
| net weight | 18.75 kg | 
| standards | EN 60947-4-1, IEC 60947-4-1, IEC 60947-1, JIS C8201-4-1, EN 60947-1 | 
| mechanical durability | 5 Mcycles | 
| device short name | LC1F | 
| range | TeSys F | 
| average impedance | 0.12 mOhm - Ith 1000 A 50 Hz | 
| [Ie] rated operational current | 1000 A (at <40 °C) at <= 440 V AC AC-1, 800 A (at <55 °C) at <= 440 V AC AC-3 | 
| [Uc] control circuit voltage | 100...250 V AC 50/60 Hz with LXE coil, 100...380 V DC with LXE coil, 110...400 V AC 40...400 Hz with LX1/LX9 coil, 110...400 V DC with LX4 coil | 
| [Uimp] rated impulse withstand voltage | 8 kV | 
| product name | TeSys F | 
| mechanical robustness | vibrations contactor open: 2 Gn, 5...300 Hz, vibrations contactor closed: 4 Gn, 5...300 Hz, shocks contactor open: 6 Gn for 1/2 sine wave (11 ms), shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms) | 
| power dissipation per pole | 120 W AC-1, 77 W AC-3 | 
| [Ith] conventional free air thermal current | 1000 A (at 40 °C) | 
| contactor application | motor control, resistive load | 
| rated breaking capacity | 6400 A conforming to IEC 60947-4-1 | 
| Irms rated making capacity | 8000 A AC conforming to IEC 60947-4-1 | 
| pole contact composition | 3 NO | 
| operating time | 40...50 ms opening for with LX4 coil, 40...80 ms closing for with LXE coil, 6...54 ms opening for with LXE coil, 60...80 ms closing for with LX1/LX9 coil, 160...180 ms opening for with LX1/LX9 coil, 60...80 ms closing for with LX4 coil | 
| hold-in power consumption in VA | 12-12 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil, 12-12 VA (at 20 °C)with LX4 coil, 7-10 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil, 4.0-5.5 VA cos phi 0.5 (at 20 °C)with LXE coil | 
| inrush power in VA | 1700-1700 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil, 1900-1900 VA (at 20 °C)with LX4 coil, 460-730 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil, 500-680 VA cos phi 0.5 (at 20 °C)with LXE coil | 
| permissible ambient air temperature around the device | -5-55 °C | 
| connections - terminals | control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end, control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end, control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²solid without cable end, power circuit: bar 2 cable(s) - busbar cross section: 60 x 5 mm, power circuit: bolted connection, control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible with cable end, control circuit: screw clamp terminals 1 cable(s) 1-4 mm², control circuit: screw clamp terminals 2 cable(s) 1-4 mm² | 
| height | 304 mm | 
| mounting support | plate | 
| compatibility code | LC1F | 
| width | 309 mm | 
| depth | 255 mm | 
| operating altitude | 3000 m without derating | 
| IP degree of protection | IP20 front face with shrouds conforming to IEC 60529, IP20 front face with shrouds conforming to VDE 0106 | 
| poles description | 3P | 
| tightening torque | control circuit: 1.2 N.m, power circuit: 58 N.m | 
| [Ue] rated operational voltage | <= 1000 V AC 50/60 Hz, <= 460 V DC | 
| utilisation category | AC-4, AC-3, AC-1 | 
| [Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1, 1500 V conforming to VDE 0110 group C | 
| control circuit voltage limits | operational: 0.85...1.1 Uc N/A 40...400 Hz with LX1/LX9 coil, operational: 0.85...1.1 Uc N/A with LX4 coil, operational: 85...275 V N/A 50/60 Hz with LXE coil, drop-out: 0...60 V N/A 50/60 Hz with LXE coil, operational: 85...418 V N/A with LXE coil, drop-out: 0...45 V N/A with LXE coil, drop-out: 0.3...0.5 Uc N/A 40...400 Hz with LX1/LX9 coil, drop-out: 0.3...0.5 Uc N/A with LX4 coil | 
| associated fuse rating | 1000 A gG at <= 440 V, 800 A aM at <= 440 V | 
| maximum operating rate | 600 cyc/h 55 °C | 
| protective treatment | TH | 
| motor power kW | 450 kW at 1000 V AC 50/60 Hz (AC-3), 450 kW at 500 V AC 50/60 Hz (AC-3), 475 kW at 660...690 V AC 50/60 Hz (AC-3), 110 kW at 400 V AC 50/60 Hz (AC-4), 450 kW at 380...400 V AC 50/60 Hz (AC-3), 450 kW at 415 V AC 50/60 Hz (AC-3), 450 kW at 440 V AC 50/60 Hz (AC-3), 250 kW at 220...240 V AC 50/60 Hz (AC-3) | 
| heat dissipation | 2.2-5.5 W, 25-25 W | 