Schneider Electric

TeSys F contactor - 4P(4 NO) - AC-1 - <= 440 V 700 A - without coil - LC1F5004

Out of stock
SKU
LC1F5004
75%
Special Price Rp 14.638.680 Regular Price Rp 58.554.720
Details

TeSys F contactor, 4 poles (4NO), 700A/1000V AC-1, for non-inductive load applications.

Contactor with no coil to allow a later selection and installation (coil to be ordered separately), it provides bolt terminals for bars or cables with lugs.

For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability.

It makes installation and maintenance easy thanks to a drawer for insertion of the selected coil and a large choice of add-on blocks and accessories (to be ordered separately).

Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

More Information
More Information
Attribute Value
SKU LC1F5004
product certifications LROS (Lloyds register of shipping), BV, RINA, CSA, DNV, UL, ABS, CB, RMRoS
ambient air temperature for storage -60-80 °C
overvoltage category III
ambient air temperature for operation -5-55 °C
[Icw] rated short-time withstand current 4200 A 40 °C - 10 s, 3200 A 40 °C - 30 s, 2400 A 40 °C - 1 min, 1500 A 40 °C - 3 min, 1200 A 40 °C - 10 min
range of product TeSys F
product or component type Kontaktor
net weight 9.75 kg
standards EN 60947-4-1, IEC 60947-4-1, IEC 60947-1, JIS C8201-4-1, EN 60947-1
mechanical durability 10 Mcycles
device short name LC1F
range TeSys F
average impedance 0.18 mOhm - Ith 700 A 50 Hz
[Ie] rated operational current 700 A (at <40 °C) at <= 440 V AC AC-1
[Uc] control circuit voltage 48...1000 V AC 40...400 Hz with LX1/LX9 coil, 48...440 V DC with LX4 coil
[Uimp] rated impulse withstand voltage 8 kV
product name TeSys F
mechanical robustness vibrations contactor open: 2 Gn, 5...300 Hz, vibrations contactor closed: 4 Gn, 5...300 Hz, shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms), shocks contactor open: 9 Gn for 1/2 sine wave (11 ms)
power dissipation per pole 88 W AC-1
[Ith] conventional free air thermal current 700 A (at 40 °C)
contactor application resistive load
rated breaking capacity 4000 A conforming to IEC 60947-4-1
Irms rated making capacity 5000 A AC conforming to IEC 60947-4-1
pole contact composition 4 NO
operating time 100...170 ms opening for with LX1/LX9 coil, 40...75 ms closing for with LX1/LX9 coil, 50...60 ms closing for with LX4 coil, 45...60 ms opening for with LX4 coil
hold-in power consumption in VA 16-20 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil, 4.54-8 VA (at 20 °C)with LX4 coil
inrush power in VA 1050-1150 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil, 990-1220 VA (at 20 °C)with LX4 coil
permissible ambient air temperature around the device -40-70 °C
connections - terminals control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end, control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end, control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²solid without cable end, power circuit: bolted connection, control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible with cable end, control circuit: screw clamp terminals 1 cable(s) 1-4 mm², control circuit: screw clamp terminals 2 cable(s) 1-4 mm², power circuit: lugs-ring terminals 2 cable(s) 240-240 mm², power circuit: bar 2 cable(s) - busbar cross section: 40 x 5 mm
height 238 mm
mounting support plate
compatibility code LC1F
width 288 mm
depth 232 mm
IP degree of protection IP20 front face with shrouds conforming to IEC 60529, IP20 front face with shrouds conforming to VDE 0106
poles description 4P
tightening torque control circuit: 1.2 N.m, power circuit: 35 N.m
[Ue] rated operational voltage <= 1000 V AC 50/60 Hz, <= 460 V DC
utilisation category AC-1
[Ui] rated insulation voltage 1000 V conforming to IEC 60947-4-1, 1500 V conforming to VDE 0110 group C
control circuit voltage limits operational: 0.85...1.1 Uc N/A 40...400 Hz with LX1/LX9 coil, operational: 0.85...1.1 Uc N/A with LX4 coil, drop-out: 0.2...0.35 Uc N/A with LX4 coil, drop-out: 0.3...0.5 Uc N/A 40...400 Hz with LX1/LX9 coil
associated fuse rating 500 A aM at <= 440 V, 800 A gG at <= 440 V
maximum operating rate 2400 cyc/h 55 °C
protective treatment TH
heat dissipation 18-18 W
PT. Telesindo Citra Sejahtera © 2025 All Rights Reserved.