Schneider Electric
TeSys GV2 - Circuit breaker - magnetic - 2.5 A - screw clamp terminals - GV2L07
Out of stock
SKU
GV2L07
Details
TeSys GV motor circuit breaker, 3 poles (3P), 2.5A/690V, for 3-phase motor applications 0.75kW@400V.
It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 100kA@400V.
Connection by screw clamp terminals.
Start-stop control by rotary handle guaranteed for 100 000 cycles AC-3.
To complete motor protection, use in association with a thermal overload relay LRD07 (to be ordered separately).
Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
More Information
| Attribute | Value |
|---|---|
| SKU | GV2L07 |
| product certifications | EAC, CCC, LROS (Lloyds register of shipping), BV, RINA, CSA, UL, IECEE CB Scheme, DNV-GL |
| ambient air temperature for storage | -40-80 °C |
| ambient air temperature for operation | -20-60 °C |
| magnetic tripping current | 33.5-33.5 A |
| range of product | TeSys GV2 |
| operating position | any position |
| product or component type | motor circuit breaker |
| net weight | 0.33 kg |
| standards | EN/IEC 60947-2, UL 60947-4-1, CSA C22.2 No 60947-4-1, EN/IEC 60947-4-1 |
| mechanical durability | 100000 cycles |
| device short name | GV2L |
| breaking capacity | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| trip unit technology | magnetic |
| range | TeSys GV |
| IK degree of protection | IK04 |
| product name | TeSys GV2 |
| mechanical robustness | shocks: 30 Gn conforming to IEC 60068-2-27, vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6 |
| power dissipation per pole | 1.8 W |
| direct connector | without |
| network frequency | 50/60 Hz conforming to IEC 60947-2 |
| connections - terminals | screw clamp terminals 2 cable(s) 1-6 mm² solid, screw clamp terminals 2 cable(s) 1.5-6 mm² flexible without cable end, screw clamp terminals 2 cable(s) 1-4 mm² flexible with cable end |
| height | 89 mm |
| compatibility code | GV2L |
| width | 45 mm |
| depth | 97 mm |
| operating altitude | 0...2000 m |
| IP degree of protection | IP20 conforming to IEC 60529 |
| [In] rated current | 2.5 A |
| network type | AC |
| poles description | 3P |
| tightening torque | 1.7 N.m on screw clamp terminals |
| electrical durability | 100000 cycles for AC-3 at 415 V |
| device application | motor |
| control type | rotary knob |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| fixing mode | 35 mm symmetrical DIN rail: clipped, panel: screwed (with 2 x M4 screws) |
| utilisation category | category A conforming to IEC 60947-2, AC-3 conforming to IEC 60947-4-1 |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| suitability for isolation | yes conforming to IEC 60947-1 |
| maximum operating rate | 40 cyc/h |
| protective treatment | TH |
| fire resistance | 960 °C conforming to IEC 60695-2-1 |
| motor power kW | 1.1-1.1 kW at 500 V AC 50/60 Hz, 0.75-0.75 kW at 400/415 V AC 50/60 Hz, 1.5-1.5 kW at 690 V AC 50/60 Hz |
| rated duty | continuous conforming to IEC 60947-4-1 |
| [Ics] rated service short-circuit breaking capacity | 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Technical Documents