Schneider Electric        
    
    
        
            
    
TeSys GV2 MAN-STARTER SHORT CIR CONTACT 575VAC 1 - GVAM11
            Out of stock
        
    
            SKU
        
GVAM11
                        Details
                    
                    
TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3.
1C/O contact for short circuit signaling.
Rated for operation up to 2A/240V AC and 1A/60V DC.
To be installed on left-hand side of the circuit breaker (1 block mounting maximum), connection by screw clamp terminals.
Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
                        More Information
                    
                        | Attribute | Value | 
|---|---|
| SKU | GVAM11 | 
| environmental characteristic | normal environment | 
| range of product | TeSys GV3, TeSys GV2 | 
| product or component type | motor circuit breaker | 
| net weight | 0.055 kg | 
| mechanical durability | 100000 cycles | 
| device short name | GVAM | 
| range | TeSys GV | 
| product compatibility | GV2ME, GV2RT, GV2L, GV3P, GV3L, GV2LE, GV2P | 
| rated operational power in VA | 36 VA at 24-24 V AC-14 - electrical durability: 1000 cycles at 1.5 A, 48 VA at 48-48 V AC-14 - electrical durability: 1000 cycles at 1 A, 72 VA at 110-127 V AC-14 - electrical durability: 1000 cycles at 0.5 A, 72 VA at 230-240 V AC-14 - electrical durability: 1000 cycles at 0.3 A | 
| range compatibility | GV2 GV2 circuit breaker, GV3 GV3P circuit breaker, GV3 GV3L circuit breaker | 
| minimum switching current | 5 mA | 
| [Ith] conventional free air thermal current | 2.5 A for fault signalling | 
| pole contact composition | 1 C/O | 
| rated operational power in W | 120 W at 240 V DC-13 - electrical durability: 100000 cycles, 140 W at 110 V DC-13 - electrical durability: 100000 cycles, 140 W at 24 V DC-13 - electrical durability: 100000 cycles, 180 W at 60 V DC-13 - electrical durability: 100000 cycles, 240 W at 48 V DC-13 - electrical durability: 100000 cycles, 15 W at 48 V DC-13 - electrical durability: 1000 cycles, 24 W at 24 V DC-13 - electrical durability: 1000 cycles, 9 W at 60 V DC-13 - electrical durability: 1000 cycles | 
| height | 89 mm | 
| compatibility code | GVAM | 
| width | 9.3 mm | 
| depth | 66 mm | 
| tightening torque | 1.4 N.m - on screw clamp terminals | 
| [Ue] rated operational voltage | 24...240 V AC, 24...60 V DC | 
| protection type | gG fuse 10 A, GB2CB... circuit breaker | 
| [Ui] rated insulation voltage | 300 V conforming to UL 508, 300 V conforming to CSA C22.2 No 14, 690 V conforming to IEC 60947-1 | 
| minimum switching voltage | 17 V | 
| auxiliary contacts operation | short-circuit signal 1 C/O | 
| mounting location | left side | 
                        Technical Documents
                    
                    
    
                