Schneider Electric
TeSys GV3 - auxiliary contact - 1 NC + 1 NO (fault) - GVAD1001
Out of stock
SKU
GVAD1001
Details
TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3.
1NO fault signaling contact + 1NC instantaneous auxiliary contact.
Instantaneous auxiliary contact rated for operation up to 6A/690V AC and 6A/240V DC.
Fault signaling contact rated for operation up to 2A/240V AC and 1A/60V DC.
To be installed on left-hand side of the circuit breaker (1 block mounting maximum), connection by screw clamp terminals.
Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
More Information
Attribute | Value |
---|---|
SKU | GVAD1001 |
environmental characteristic | normal environment |
range of product | TeSys GV3, TeSys GV2 |
product or component type | motor circuit breaker |
net weight | 0.055 kg |
mechanical durability | 100000 cycles |
device short name | GVAD |
range | TeSys GV |
product compatibility | GV2ME, GV2RT, GV2L, GV3P, GV3L, GV2LE, GV2P |
rated operational power in VA | 300 VA at 48-48 V AC-15 - electrical durability: 100000 cycles, 414 VA at 690-690 V AC-15 - electrical durability: 100000 cycles, 500 VA at 110-127 V AC-15 - electrical durability: 100000 cycles, 500 VA at 500-500 V AC-15 - electrical durability: 100000 cycles, 650 VA at 440-440 V AC-15 - electrical durability: 100000 cycles, 720 VA at 230-240 V AC-15 - electrical durability: 100000 cycles, 850 VA at 380-415 V AC-15 - electrical durability: 100000 cycles, 36 VA at 24-24 V AC-14 - electrical durability: 1000 cycles, 48 VA at 48-48 V AC-14 - electrical durability: 1000 cycles, 72 VA at 110-127 V AC-14 - electrical durability: 1000 cycles |
minimum switching current | 5 mA |
[Ith] conventional free air thermal current | 6 A, 2.5 A for fault signalling |
pole contact composition | 1 NO + 1 NC |
rated operational power in W | 120 W at 240 V DC-13 - electrical durability: 100000 cycles, 140 W at 110 V DC-13 - electrical durability: 100000 cycles, 140 W at 24 V DC-13 - electrical durability: 100000 cycles, 180 W at 60 V DC-13 - electrical durability: 100000 cycles, 240 W at 48 V DC-13 - electrical durability: 100000 cycles, 15 W at 48 V DC-13 - electrical durability: 1000 cycles, 24 W at 24 V DC-13 - electrical durability: 1000 cycles, 9 W at 60 V DC-13 - electrical durability: 1000 cycles |
height | 89 mm |
compatibility code | GVAD |
width | 9.3 mm |
depth | 66 mm |
tightening torque | 1.4 N.m - on screw clamp terminals |
[Ue] rated operational voltage | 48...690 V AC, 24...240 V DC |
protection type | gG fuse 10 A, GB2CB... circuit breaker |
[Ui] rated insulation voltage | 300 V conforming to UL 508, 300 V conforming to CSA C22.2 No 14, 690 V conforming to IEC 60947-1 |
minimum switching voltage | 17 V |
auxiliary contacts operation | fault signal 1 NO |
mounting location | left side |