Schneider Electric

TeSys GV3 - auxiliary contact - 1 NO + 1 NC (fault) - GVAD0110

Out of stock
SKU
GVAD0110
38%
Special Price Rp 267.022 Regular Price Rp 430.680
Details

TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3.

1NC fault signaling contact + 1NO instantaneous auxiliary contact.

Instantaneous auxiliary contact rated for operation up to 6A/690V AC and 6A/240V DC.

Fault signaling contact rated for operation up to 2A/240V AC and 1A/60V DC.

To be installed on left-hand side of the circuit breaker (1 block mounting maximum), connection by screw clamp terminals.

Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

More Information
More Information
Attribute Value
SKU GVAD0110
environmental characteristic normal environment
range of product TeSys GV3, TeSys GV2
product or component type motor circuit breaker
net weight 0.055 kg
mechanical durability 100000 cycles
device short name GVAD
range TeSys GV
product compatibility GV2ME, GV2RT, GV2L, GV3P, GV3L, GV2LE, GV2P
rated operational power in VA 300 VA at 48-48 V AC-15 - electrical durability: 100000 cycles, 414 VA at 690-690 V AC-15 - electrical durability: 100000 cycles, 500 VA at 110-127 V AC-15 - electrical durability: 100000 cycles, 500 VA at 500-500 V AC-15 - electrical durability: 100000 cycles, 650 VA at 440-440 V AC-15 - electrical durability: 100000 cycles, 720 VA at 230-240 V AC-15 - electrical durability: 100000 cycles, 850 VA at 380-415 V AC-15 - electrical durability: 100000 cycles, 36 VA at 24-24 V AC-14 - electrical durability: 1000 cycles, 48 VA at 48-48 V AC-14 - electrical durability: 1000 cycles, 72 VA at 110-127 V AC-14 - electrical durability: 1000 cycles
minimum switching current 5 mA
[Ith] conventional free air thermal current 6 A, 2.5 A for fault signalling
pole contact composition 1 NO + 1 NC
rated operational power in W 120 W at 240 V DC-13 - electrical durability: 100000 cycles, 140 W at 110 V DC-13 - electrical durability: 100000 cycles, 140 W at 24 V DC-13 - electrical durability: 100000 cycles, 180 W at 60 V DC-13 - electrical durability: 100000 cycles, 240 W at 48 V DC-13 - electrical durability: 100000 cycles, 15 W at 48 V DC-13 - electrical durability: 1000 cycles, 24 W at 24 V DC-13 - electrical durability: 1000 cycles, 9 W at 60 V DC-13 - electrical durability: 1000 cycles
height 89 mm
compatibility code GVAD
width 9.3 mm
depth 66 mm
tightening torque 1.4 N.m - on screw clamp terminals
[Ue] rated operational voltage 48...690 V AC, 24...240 V DC
protection type gG fuse 10 A, GB2CB... circuit breaker
[Ui] rated insulation voltage 300 V conforming to UL 508, 300 V conforming to CSA C22.2 No 14, 690 V conforming to IEC 60947-1
minimum switching voltage 17 V
auxiliary contacts operation fault signal 1 NC
mounting location left side
PT. Telesindo Citra Sejahtera © 2025 All Rights Reserved.